25.14
Construction of C.C. Approch Road for Govt. School Buld Tolapara,Dhaniyadoli,
Agreement No - 69/DL / 2020-21 Date of Testing-09/05/20222
FLAKINESS INDEX OF 20mm Metal
Size of Agg. Wt. Of Wt. Of Passing wt. Of Retaind
Passing through Retain through sample W gm Through thicknessThrough length
IS seive mm IS seive mm (200 pieces) gauge w gm gauge w gm
25 20 0 0
20 16 85 12 73 9
16 12.5 204 24 180 18
12.5 10 564 104 460 26
10 6.3 269 23 246 24
Total 1122 163 959 89
Flakiness Index 14.53 % 9.28 %
Elogaction Index 9.28
23.81
niyadoli,
P.W.D. REGIONAL RESEARCH LABORATORY BILASPUR ZONE BILASPUR C.G. O/o THE
CHIEF ENGINEER P.W.D. BILASPUR ZONE BILASPUR (C.G.)
Marshall Stability Test
Location/Chainage :- Dagouri -Bojpuri Road. Date of Sampled : 09/02/23
Description of Layer:- DBM Grade II Date of Testing : 10/02/23
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 70 1208 707 1212 505 2.392 281 1414.554 0.86 12.165 3.20
2 6.00 69 1209 705 1213 508 2.380 284 1429.656 0.86 12.295 3.30
3 70 1210 706 1215 509 2.377 284 1429.656 0.86 12.295 3.30
Avg. of Three Specimen Avg. 2.383 12.25 3.27
1 38 100.00 100.00
2 26.5 98.04 90-100
3 19.0 88.38 71-95
4 13.2 66.86 56-80
5 4.75 47.82 38-54
6 2.36 35.90 28-42
7 0.3 15.04 7 -21
8 0.1 3.40 7 -8
SI. NO. Test Particular Result as per Design Specified Limit As per
MORTH -5 th Revision
Note : 1. Test Report is given on the basis of material supplied by the Contractor / Client .
2. This Report is being issued on the specific understanding that Regional Research Lab PWD Bilaspur
not in any way be involved in any action following the interprectation of the above Result .
3. This Report shall not be reproduced except in full without written approval from lab.
3 Softening Point 0C 50
PROPORTION OF MIX
SI.No. Name of Matirial Percentage
1 FR-I (20mm Metal)
22
2 FR-I (10mm Metal)
30
3 FR-II (6 mm Metal)
21
4 FR-III (Stone Dust)
25
5 FR-IV (Cement)
2
Total 100
Name of work - Const. of Widening & Strengthing of Khamhi to Khudiya Road , Length- 13.29 KM
Contractor Name …Shri Kanhaiyalal Agrwal
Agreement No - 01/DL / 2022 -23
SampleRecived Date :- 07/06/2022 Unseal Sample
Date :-09/06/2022
Determination of liquid limit ( LL) of G.S.B. Gr-III
20 mm Wt Taken 5000
Sieve in Cummulity
mm Wt of Sample Wt. of % % % Passing Limit
40 0 0 0 100.00 100
20 2347 46.94 46.94 53.06 95-100
10 2649 52.98 99.92 0.08 25-55 2412.5
4.75 0 0.00 99.92 0.08 0-10 2193.5
4996
10 mm Wt Taken 5000
Sieve in Cummulity
mm Wt of Sample Wt. of % % % Passing Limit
40 0 0 0 100.00 100
20 0 0.00 0.00 100.00 100
10 541 10.82 10.82 89.18 40-85 2412.5
4.75 4163 83.26 94.08 5.92 0-10 4301.5
4704
Specification Limits
Upper
100
100
95
80
54 0.00
42
21
8
P.W.D. REGIONAL RESEARCH LABORATORY BILASPUR ZONE BILASPUR C.G. O/o
THE CHIEF ENGINEER P.W.D. BILASPUR ZONE BILASPUR C.G.
Sub: Mix Design of Dense Graded Bituminous Macadam Grade-II of Strengthing of Dagouri to Bojpuri Road Length -9.00KM
PROPORTION
OF MIX
SI. NO. Name of Material Bulk Apparent Water Absorption
Specific Specigic
Gravity Gravity
RR No. 1791/Lab/06/12/2023
Letter No. 138/Tec,./No.1 Bilaspur/ 06.02.2023
Record. From S.D.O. P.W.D. Sub Division No.1 Bilaspur
40 mm Metal 01Bags,20mm Metal 03 Bags, 10mm Metal 03 Bags, 6mm Metal 03 Bags ,
Dust 03 Bags A.C.C. Cement 02Bags & Bitumen Sample received from S.D.O. P.W.D.
Sub Division Lormi for Construction of Strengthing of Dagouri to Bojpuri Road ,Length-
9.0 KM.
Above sample have been tested and test report is put up for approval please.
IO.
Done
Mix Design of Bituminous Concrete Grade-II of Strengthing of Dagori to Bojpuri Road
DBM Water Absorpation
Brick No. Metal Dry wt. wet.wt. Wet-Dry % Water Av.water
1 20mm 315 316 1 0.317
1 10mm 428 431 3 0.701
2 6mm 448 454 6 1.339
3 Stone Dust 484 492 8 1.653 0.74
4
5
P.W.D. REGIONAL RESEARCH LABORATORY BILASPUR ZONE BILASPUR C.G. O/o THE CHIEF ENGINEER P.W.D. BILASPUR ZONE BILASPUR
C.G.
Memo No. 733/Tech/2020-21 Bilaspur. Date 30/06/2021
To
Sub Divisional officer
PWD Sub Divisional No. 01 Bilaspur (C.G.)
PWD Sub Divisional No. 01 Bilaspur (C.G.)
Sub: Test Result of C.C. Core of Construction of C.C. Road from Pld Kerla School to Bscchaumal House at wart No. 65
Ag. No. 14 DL 2020-21
Agency Maa Bhagwati Construction "A" Class Contractor.
Ref: Your memo no. 733 Dated 30/06/2021
Performance Standard :- IS 516, MORTH 5th Revision
TEST RESULT OF CONCRETE CORE
S.No. Location from which the Height of Diameter H/D H/D Area in Crushing Cylindrical Crushing Average Average
sample is collected core in cms in cms Ratio correction cm2 load Crushing Strenght of core Crushing Characteristic
factor obtained in Strenght of after H/D Strength in Compressive
kg core in kg/ cm correction in kg/cm2 Strength of Cubes
kg./cm2 in kg/cm2
1 2 3 4 5 6 7 8 9 10 11 12
1 C.C. Road 15 10 1.50 0.945 78.50 19367 247.00 233
Note : 1. Test Report is given on the basis of material supplied by the Contractor / Client .
2. This Report is being issued on the specific understanding that Regional Research Lab PWD Bilaspur not in any way be involved in any action following the
interprectation of the
3. This Report shall notabove Result . except in full without written approval from lab.
be reproduced
4. Calculation of Crushing Strength of Core and Average Characterisris Strength of cube is calculated according to Clause 903.2.2 of MORTH&H 5th Revision 2013
Test Conducted By Me
Sub: Mix Dising of GSB GR -V- For the Proposed Construction work form jaijaipur to Galgaldih Road
Length 1.30 km
Ref: Letter No. 239 shilp champa Dated 02/01/2021
Name of Contractor- M/s Sanjay kumar kedia A-5 class Contractor ,Post -Baradwar, Distt Janjgir -Champa
Agreement No:- 57 /DL of 2021-22
Dear sir,
vide subject and reference cited above the Test Results Report is as follows-
PARTICULAR OF SAMPLES (S)
Nature:- Aggreement 40mm 20mm 10mm 6mm & stone Dust
Sample No (s) Details :- one sample of Each
Quantity Approx :- Sulfficient
Packing/Container:- poly Bags
Date of Collection / Manufacture :- Not Specified Dt. Of Receipt in the Lab:-
LAB TEST JOB NO. :- MGTL/ TRR / B-22022111/001 TEST RESULTS
Sr.No. Name of Test Test Method Results Unit
A) G.S.B. Mix Design GR -V
1 Blending of Matarial As per is specification As per Table 1 Below %
2 O.M.C. & M.D.D. As per is specification As per Table 2 Below %&gm/cm
3 C.B.R. Value As per is specification As per Table 2 Below %
4 LL. PL. & PI As per is specification As per Table 2 Below %
Table -1
Sieve Nos. Percentage Percentage Percentage Percentage Percentage Percentage % Passing As per
in mm passing of passing of passing of passing of passing of passing of MORTH 5th REV
Aggregate Aggregate Aggregate Aggregate Aggregate Aggregate
40mm 40mm 40mm 40mm 40mm 40mm
% BLEND 30 14 12 16 28 100
Sub: Mix Dising of GSB GR -V- For the Proposed Construction work form jaijaipur to Galgaldih Road
Length 1.30 km
Ref: Letter No. 239 shilp champa Dated 02/01/2021
Name of Contractor- M/s Sanjay kumar kedia A-5 class Contractor ,Post -Baradwar, Distt Janjgir -Champa
Agreement No:- 57 /DL of 2021-22
Dear sir,
vide subject and reference cited above the Test Results Report is as follows-
PARTICULAR OF SAMPLES (S)
Nature:- Aggreement 40mm 20mm 10mm 6mm & stone Dust
Sample No (s) Details :- one sample of Each
Quantity Approx :- Sulfficient
Packing/Container:- poly Bags
Date of Collection / Manufacture :- Not Specified Dt. Of Receipt in the Lab:-
LAB TEST JOB NO. :- MGTL/ TRR / B-22022111/001 TEST RESULTS
Sr.No. Name of Test Test Method Results Unit
A) G.S.B. Mix Design GR -V
1 Blending of Matarial As per is specification As per Table 1 Below %
2 O.M.C. & M.D.D. As per is specification As per Table 2 Below %&g
3 C.B.R. Value As per is specification As per Table 2 Below %
4 LL. PL. & PI As per is specification As per Table 2 Below %
Table -1
Sieve Nos. Percentag Percentag Percentag Percentag Percentag Percentag % Passing As per MORTH 5th
in mm e passing e passing e passing e passing e passing e passing REV
of of of of of of
Aggregate Aggregate Aggregate Aggregate Aggregate Aggregate
40mm 40mm 40mm 40mm 40mm 40mm
% BLEND 30 14 12 16 28 100
75MM 100 100 100 100 100 100 100
53MM 100 100 100 100 100 100 80-100
26.5 MM 10.48 100 100 100 100 73.14 55-90
9.5 MM 5.24 12.42 21.72 100 100 49.92 35-65
4.75 MM 0.87 3.26 6.04 67.36 90.34 37.52 25-50
2.38 MM 0.0 0.0 0.78 15.42 51.52 16.99 10--20
0.85 MM 0.0 0.0 0.0 0.39 27.07 7.64 2--10
0.425 0.0 0.0 0.0 0 8.64 2.42 0-5
MM
gir -Champa
n the Lab:-
Marshal Geo Test Laboratory
for Testing of civil Engineering Materials
Sheet 1 of 2
T.R. No./MGTL/ TRR/B-22022111/001 Date :-
To
Sub Divisional officer
PWD Sub Divisional No. 2 Katghora
PWD Sub Divisional korba
Sub: Mix Dising of GSB GR -V- For the Proposed Construction work form jaijaipur to Galgaldih Road
Length 1.30 km
Ref: Letter No. 239 shilp champa Dated 02/01/2021
Name of Contractor- M/s Sanjay kumar kedia A-5 class Contractor ,Post -Baradwar, Distt Janjgir -Champa
Agreement No:- 57 /DL of 2021-22
Dear sir,
vide subject and reference cited above the Test Results Report is as follows-
PARTICULAR OF SAMPLES (S)
Nature:- Aggreement 40mm 20mm 10mm 6mm & stone Dust
Sample No (s) Details :- one sample of Each
Quantity Approx :- Sulfficient
Packing/Container:- poly Bags
Date of Collection / Manufacture :- Not Specified Dt. Of Receipt in the Lab:-
LAB TEST JOB NO. :- MGTL/ TRR / B-22022111/001 TEST RESULTS
Sr.No. Name of Test Test Method Results Unit
A) G.S.B. Mix Design GR -V
1 Blending of Matarial As per is specification As per Table 1 Below %
2 O.M.C. & M.D.D. As per is specification As per Table 2 Below %&g
3 C.B.R. Value As per is specification As per Table 2 Below %
4 LL. PL. & PI As per is specification As per Table 2 Below %
Table -1
Sieve Nos. Percentag Percentag Percentag Percentag Percentag Percentag % Passing As per MORTH 5th
in mm e passing e passing e passing e passing e passing e passing REV
of of of of of of
Aggregate Aggregate Aggregate Aggregate Aggregate Aggregate
40mm 40mm 40mm 40mm 40mm 40mm
% BLEND 30 14 12 16 28 100
75MM 100 100 100 100 100 100 100
53MM 100 100 100 100 100 100 80-100
26.5 MM 10.48 100 100 100 100 73.14 55-90
9.5 MM 5.24 12.42 21.72 100 100 49.92 35-65
4.75 MM 0.87 3.26 6.04 67.36 90.34 37.52 25-50
2.38 MM 0.0 0.0 0.78 15.42 51.52 16.99 10--20
0.85 MM 0.0 0.0 0.0 0.39 27.07 7.64 2--10
0.425 0.0 0.0 0.0 0 8.64 2.42 0-5
MM
gir -Champa
n the Lab:-
Water Absorption of Aggregates
S,N. Specimen No. Weight of Saturated Weight of Oven Water Absorption (%) B-A
Surface Dry Sample Dried Sample = --------x 100
B (g) A (g)
1 2 3 4 5
1
3
REGIONAL RESEARCH LABORATORY P.W.D. BILASPUR ZONE BILASPUR (C.G.)
Memo No. …………………………/2021-22 Bilaspur. Date……………………………….
To
Sub Divisional officer
PWD Sub Divisional No. 2 Katghora
PWD Sub Divisional korba
Sub: Test Result of C.C. Core of Construction of C.C. Road from Pld Kerla School to Bscchaumal House at wart No. 65
Ag. No. 31/10/2021
Agency M/s Satyam Kesharwani
Ref: Your memo no. 325 Dated 20/10/2021
Performance Standard :- IS 516, MORTH 5th Revision
TEST RESULT OF CONCRETE CORE
S.No. Location from which the Height of Diameter H/D H/D Area in Crushing Cylindrical Crushing Average Average
sample is collected core in cms in cms Ratio correction cm2 load Crushing Strenght of core Crushing Characteristic
factor obtained in Strenght of after H/D Strength in Compressive
kg core in kg/ cm correction in kg/cm2 Strength of Cubes
kg./cm2 in kg/cm2
1 2 3 4 5 6 7 8 9 10 11 12
1 C.C. Road 15 10 1.50 0.945 78.50 19367 247.00 233
Note : 1. Test Report is given on the basis of material supplied by the Contractor / Client .
2. This Report is being issued on the specific understanding that Regional Research Lab PWD Bilaspur not in any way be involved in any action following the
interprectation of the
3. This Report shall notabove Result . except in full without written approval from lab.
be reproduced
4. Calculation of Crushing Strength of Core and Average Characterisris Strength of cube is calculated according to Clause 903.2.2 of MORTH&H 5th Revision 2013
Test Conducted By Me