You are on page 1of 5

Kattampally Thadikkadavu Road Work

Client :PWD
Contractor :ULCCS
CALIFORNIA BEARING RATIO TEST
(As per IS 2720, Part-16)
Type of material Cutting earth Soil Date of testing 26/7/20

Location 2/500 Region Tested by ULCCS QC Lab

Sampled from From site Material MDD/OMC 1.688 / 16.34 %


MOISTURE CONTENT AND UNIT WEIGHT OF TEST SAMPLES
S.No DESCRIPTION MOULD NO. A MOULD NO. B MOULD NO. C
A. No.of layers 5 5 5
B. No.of blows per layer 10 25 55
C. Condition of sample while SOAKING BEFORE AFTER BEFORE AFTER BEFORE AFTER
D. Wt.of mould(gm) 6960 6960 7038 7038 6828 6828
E. Wt.of wet sample+mould(gm) 10768 10780 11106 11142 11283 11309
F. Wt.of wet sample(E-D)(gm) 3808 3820 4068 4104 4455 4481
G. Volume of mould/sample (cc) 2250 2250 2250 2250 2250 2250
H. Wet density (F/G)(gm/cc) 1.692 1.698 1.808 1.824 1.980 1.992
J. Moisture determination
K. Container no. 1 2 3 4 5 6
L. Wt.of container(gm) 16.14 16.00 15.61 15.60 16.20 16.10
M. Wt.of wet sample+cont.(gm) 47.3 52 47.52 52.13 50.23 57.45
N. Wt.of dry sample+cont.(gm) 44.12 48.21 44.21 48 46.1 52.2
P. Wt.of water(M-N)(gm) 3.18 3.79 3.31 4.13 4.13 5.25
Q. Wt.of dry sample(N-L)(gm) 27.98 32.21 28.6 32.4 29.9 36.1
R. Water content[(P/Q)x100](%) 11.37 11.77 11.57 12.75 13.81 14.54
S. Dry density{H/[1+(R/100)]}(gm/cc) 1.520 1.519 1.620 1.618 1.740 1.739
LOAD PENETRATION TEST DATA
Penetrat Proving Proving Proving
Corrected Corrected Corrected
GENERAL INFORMATION ion ring ring ring
load(kg) load(kg) load(kg)
(mm) reading reading reading
0 0 0 0 0 0 0
Type of compaction used: Static/ Dynamic
0.5 6.1 23.89 7.2 28.20 14 54.83
1.0 10.6 41.51 14.5 56.79 20.3 79.50
Period of soaking: 4 days
1.5 14.3 56.00 19.5 76.37 26 101.83
2.0 16.9 66.19 23 90.08 29.6 115.93
Wt.of surcharge used (kg): 2.50x2
2.5 19.3 75.59 25.9 101.43 32.6 127.67
3 20.8 81.46 28.5 111.62 34 133.16
Proving ring capacity (kN): 30
4.0 22.3 87.34 30.6 119.84 36 140.99
5.0 23.5 92.04 32.2 126.11 37 144.91
Proving ring Identification: sr no. 154
7.5 25 97.91 35 137.07 38 148.82
10.0 26 101.83 36 140.99 39 152.74
Proving ring factor: 3.9164 kg
12.5 27.2 106.53 37 144.91 40 156.66
Corrected unit load from graph(kg) for 2.5mm 75.59 101.43 127.67
Corrected unit load from graph(kg) for 5.0mm 92.04 126.11 144.91
CBR at 2.5mm (%) 5.52 7.40 9.32
CBR at 5.0mm(%) 4.48 6.14 7.05
CBR reported (%) 7.4
For ULCCS For Department

Name :_____________________ Name :__________________

Sign.:______________________ Sign.:___________________
Kattampally Thadikkadavu Road Work
Client :PWD
Contractor :ULCCS
CALIFORNIA BEARING RATIO TEST
(Graph of Load v/s Penetration)
Type of material Soil Date of testing 26/7/20
Location 2/500 Region Tested by ULCCS QC Lab
Sampled from From site Material
MDD/OMC
1.688 /16.34 %
No of blows 10 BLOWS

LOAD Vs PENETRATION GRAPH

120

100

80
load in kg

60

40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

penetration ,mm

Results
Mould no. A
Corrected CBR value at 2.5mm 5.52
Corrected CBR value at 5.0mm 4.48
CBR reported (%) = 5.52

For ULCCS For Department

Name :_____________________ Name :__________________

Sign.:______________________ Sign.:___________________
Kattampally Thadikkadavu Road Work
Client :PWD
Contractor :ULCCS
CALIFORNIA BEARING RATIO TEST
(Graph of Load v/s Penetration)
Type of material Soil Date of testing 26/7/2020
Location 2/500 region Tested by ULCCS QC Lab
Sampled from From site Material
MDD/OMC
1.688 / 16.34%
No of blows 25 BLOWS

LOAD Vs PENETRATION GRAPH

160

140

120

100
load in kg

80

60

40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

penetration ,mm
Results
Mould no. B
Corrected CBR value at 2.5mm 7.4
Corrected CBR value at 5.0mm 6.14
CBR reported (%) = 7.4

For ULCCS For Department

Name :_____________________ Name :__________________

Sign.:______________________ Sign.:___________________
Kattampally Thadikkadavu Road Work
Client :PWD
Contractor :ULCCS
CALIFORNIA BEARING RATIO TEST
(Graph of Load v/s Penetration)
Type of material Soil Date of testing 26/7/20
Location 2/500 Region Tested by ULCCS QC Lab
Sampled from Site Material
MDD/OMC
1.688 /16.34%
No of blows 55 BLOWS

LOAD Vs PENETRATION GRAPH

180

160

140

120
load in kg

100

80

60

40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

penetration ,mm

Results
Mould no. C
Corrected CBR value at 2.5mm 9.32
Corrected CBR value at 5.0mm 7.05
CBR reported (%) = 9.32

For ULCCS For Department

Name :_____________________ Name :__________________

Sign.:______________________ Sign.:___________________
Kattampally Thadikkadavu Road Work
client :PWD
contractor : ULCCS
GRAPHICAL ANALYSIS OF CBR FOR SOIL

Location 2/500 region Date of Casting 23/7/20


Type of Material Soil Date of Testing 26/7/20
MDD : 1.688 Surcharge Weight 5 kg
OMC 16.34% Ring Factor 3.9164 Kg
Total weight of sample taken: 18 Kg Period of Soaking 96 hrs
Type of compaction 10 blows 25 blows 55 Blows
Dry Density 1.520 1.620 1.740
CBR at penetration 2.5 mm 5.52 7.40 9.32
CBR AT 97% COMPACTION 7.4

20.00
19.00
18.00
17.00
16.00
15.00
14.00
penetration (mm)

13.00
12.00
11.00
10.00
9.00
8.00
7.00
6.00
5.00
4.00
1.350 1.380 1.410 1.440 1.470 1.500 1.530 1.560 1.590 1.620 1.650 1.680 1.710 1.740 1.770 1.800 1.830 1.860 1.890 1.920 1.950
mdd value (gm/cc)

97% of Max Dry Density = 1.637 gm/cc

C.B.R. corresponding to 97% of dry density Say 7.4%


Remarks :

For ULCCS For Department

Name :_____________________ Name :__________________

Sign.:______________________ Sign.:___________________