The sizing process begins with Another way of stating this is that
inputting (4) design criteria related drawings refer to “size” as the
to internal velocities: maximum nozzle size which can
be accommodated based upon the
1. Average molecular weight diameter and length of the vessel
of the gas whereas the calculation of the
2. Design (maximum) minimum nozzle size required is
temperature based upon creation of a proper
3. Design (minimum) vortex within the separator body.
pressure
4. Volumetric flow (the “Chosen Size”: Beyond the
calculator will convert Initial Calculations
mass flow to volumetric The chosen size is a feature
flow) enabling you to quickly compare
key performance characteristics
“Sizing” for two types of applicable to standard separator
separators are automatically designs. In the following example
calculated, referred to as the a 2.29” size is “required”, thus in
“standard separator size” and the actuality it corresponds to at least
“receiver separator size”. Receiver a 2.50 inch size, but we can use
separators have a complex design this tool to select larger sizes also;
and are used to remove a higher in our example the performance
volume of droplets for a given size information for the 3.00 inch size
vessel body. Refer to “standard is shown.
separator size” for all other
designs. It is important to note
1
Factory Direct Pipeline Products, Inc. Copyright © 2020
Size Matters
Understanding Sizing Factors for Centrifugal Separators
By: Chris Pasquali, CEO Factory Direct Pipeline Products, Inc.
Got “Slugs”?
Separators designed for
condensate removal
equivalent to ≥ 20% of the
separators maximum capacity
will handle most “liquid slugs”
associated with upset
conditions or low sections of
piping.
Likewise use the liquid removal capacity chart to Our sizing tool is available to assist you with a better
determine if the desired separator design satisfies your understanding of your options. Such options include the
requirements; if not, increase the chosen size until it different styles of centrifugal separators offered but you
does. can also use the calculations to compare centrifugal
separators to vane and mesh pad style separators.
Understanding “Maximum Capacity” Typically vane and mesh style separators need to be
The calculated maximum capacity of the separator is physically larger (more expensive) and have a higher
based upon the standardized volumetric flow (Qc) pressure drop, not to mention loss of efficiency at low
which is also converted to weight flow because flow rate conditions (such as start-up and shut down of
entrained droplet removal capacity is expressed as a a system).
percentage of its maximum weight flow capacity. The
percentage of maximum capacity provides another way Visit us at http://www.fdpp.com and let us know how
to evaluate tolerance for surges in flow. The maximum we can assist you with your gas/liquid separation
capacity calculation is accurate to within 2% for 6” to application!
32” sizes and 4% for other sizes. Chris Pasquali has provided sales and engineering support for the Wright-
Austin product line since 2001, trained by both Hayward and Eaton.