You are on page 1of 2

AUTOMOTIVE ELECTRICAL APS-SUPPLY.

COM

Klixon S Series (SLA, SDLA, SDLM)


SDLM 35 to 150 Amp Commercial Thermal Circuit Breaker
Description
The Klixon® S series thermal breakers are designed to protect wiring and
meet the harshest environmental requirements. The sealed circuit breakers
are weatherproof for protection against moisture, dust, grease, fuel vapors
and other harsh environments. The S series breakers are lightweight and
designed to interrupt short circuits or overloads and combine trip-free
protection with fast response time. Typical applications are protection of wire
and cable of accessory circuits, equipment and battery protection on heavy
trucks, buses, construction equipment, off-road vehicles, marine, recreational
vehicles (RVs) and electric (hybrid) vehicles, and battery chargers. The S
series is available in both open and sealed body configurations with manual
and automatic reset options.

Features and Benefits


• 30VDC, 35 to 150 Amps
• Open and sealed assemblies, manual and automatic reset options

Series (SLA, SDLA, SDLM) • Ignition protected


• UL Recognized E69772

mercial Thermal Circuit Breaker Tech Specs


Calibration: 200% rated current, 77°F (25°C) 35 to 150 Amps: 8 to 100 seconds
Ultimate Trip at 77°F (25°C) Must hold 100%, Must trip 135%
Endurance Per SAE J1625
Interrrupt Current Capacity Per SAE J1625 and ABYC E-11
Mechanical Vibration Per SAE J1455, 4G’s, 10-2K Hz
Voltage Breakdown Per SAE J1625 500VAC
Salt Spray Per SAE J1625, 96 hours
Voltage Drop Per SAE J1625
ORDERING INFORMATION Weight (with mounting nuts)
SDLM (A): 75 grams (71 grams) max
SLA: 62 grams max
Ordering Information
Part No. Description
X−X−X KLI-SDLM105i
KLI-SDLM120i
Klixon SDLM Series 105 Amp Commercial Thermal Circuit Breaker
Klixon SDLM Series 120 Amp Commercial Thermal Circuit Breaker
KLI-SDLM150i Klixon SDLM Series 150 Amp Commercial Thermal Circuit Breaker
KLI-SDLM35i Klixon SDLM Series 35 Amp Commercial Thermal Circuit Breaker
Configuration
KLI-SDLM40i Klixon SDLM Series 40 Amp Commercial Thermal Circuit Breaker
SLA = Auto, open unit KLI-SDLM50i Klixon SDLM Series 50 Amp Commercial Thermal Circuit Breaker
SDLA = Auto, sealed unit KLI-SDLM60i Klixon SDLM Series 60 Amp Commercial Thermal Circuit Breaker
SDLM = Manual, sealed unit KLI-SDLM70i Klixon SDLM Series 70 Amp Commercial Thermal Circuit Breaker
KLI-SDLM80i Klixon SDLM Series 80 Amp Commercial Thermal Circuit Breaker
KLI-SDLM90i Klixon SDLM Series 90 Amp Commercial Thermal Circuit Breaker

Amp Rating
(35, 40, 45, 50, 60, 70, 80, 90, 100,
s
105, 120, 135, 150)

Mounting Nuts
= None
th I = Optional mounting nuts

Authorised Importer and Master Distributor

APS USA APS Australia APS: Singapore


610 Gateway Center Way, Suites J & K U48 / 9 Vision Street, Colombia
San Diego, CA 92102 USA Wangara, WA 6065 Australia Chile
P: 1 619 263 4164 Phone: 61 (8) 9302 2369 Perú
www.aps-supply.com F: 1 619 263 6814 Fax: 61 (8) 6305 0047 Brasil
AUTOMOTIVE ELECTRICAL APS-SUPPLY.COM

Klixon S Series (SLA, SDLA, SDLM)


TRIP CURVE
TRIP - Approximate
CURVE Time,
- Approximate Current
Time, Characteristics
Current At 77°F
Characteristics (25°C)
At 77°F (25°C)
Current in % Rated Load
Current in % Rated Load

10001000
Trip Curve
TRIP CURVE - Approximate Time,Time,
- Approximate Current Characteristics
Current At 77°F (25°C)
Characteristics At 77°F (25°C)
500 500
Current in % Rated Load

1000

500

100 100
.10 .10 1 1 10 10 100 100 10001000 10,000
10,000
TripTrip
Time in Seconds
Time in Seconds
100
.10 1 10 100 1000 10,000

Trip Time in Seconds


DIMENSIONS
DIMENSIONS
Dimensions - -SDLM
SDLM
- SDLM DERATING
DERATING CURVE
CURVE
Derating Curve

INCHES [MM] [MM]


INCHES
160˚F160˚F 71˚C 71˚C
DIMENSIONS - SDLM Ambient Temperature in °F, °C DERATING3CURVE4
Ambient Temperature in °F, °C
140˚F140˚F 60˚C 60˚C
3 4
100˚F100˚F
160˚F 38˚C 38˚C
71˚C
INCHES [MM] Ambient Temperature in °F, °C
140˚F 60˚C
70˚F 70˚F 3 4 77°F77°F
, 25°C
, 25°C
21˚C 21˚C
1 1 2 2
100˚F 38˚C
2.930 [74.42]
32˚F 32˚F 0˚C 0˚C
2.930 [74.42]
MAX MAX
70˚F
77°F, 25°C 21˚C
.750 [19.05]
.750 [19.05]
PUSH BUTTON 0˚F 0˚F 1 2 -18˚C-18˚C
.580 [14.73]
.580 [14.73] .540 [13.72] (RED) PUSH BUTTON
.540 [13.72]
(RED)
2.930 [74.42]
32˚F 0˚C
MAX -40˚F-40˚F -40˚C-40˚C
.750 [19.05]
-60˚F-60˚F -51˚C-51˚C
.540 [13.72]
2X (Ø .261
PUSH BUTTON
[Ø.261
6.63])
0˚F -18˚C
.580 [14.73] 2X (RED)
(Ø [Ø 6.63]) 40 4060 6080 100 100
80 120 120
140 140
160 160
180 180
MOUNTING HOLE HOLE
MOUNTING
10-32-UNF-2B
10-32-UNF-2B
1.650 [41.91]
MOUNTING NUTS NUTS
MOUNTING -40˚FUltimate TripTrip
Ultimate in %inRated Load
% Rated Load -40˚C
1.650 [41.91] FURNISHED WHENWHEN
FURNISHED
MAX MAX SPECIFIED
SPECIFIED -60˚F -51˚C
2X (Ø .261 [Ø 6.63]) 40 60 80 100 120 140 160 180
MOUNTING HOLE
10-32-UNF-2B Performance
Performancecharacteristics
characteristics are based
are based on room
on room
2XMOUNTING
2X PRE-ASM NUT NUT
PRE-ASM NUTS
temperature Ultimate
(77°F,(77°F,
25°C). ConsultTrip in % Rated
Derating curve Load
for for
1.650 [41.91]
.590 [14.99]
MAX
.590 [14.99]
FURNISHED WHEN temperature 25°C). Consult Derating curve
SPECIFIED
2X THREADED STUD STUD
2X THREADED ambient temperatures
ambient temperatures significantly higher
significantly or lower
higher or lowerthanthan
1.009 [25.63] 1/4-28 1/4-28
UNF-2A
1.009 [25.63] UNF-2A
standard room
standard temperature.
room temperature.
Performance characteristics are based on room
.284 [7.21]
.284 [7.21] 2X PRE-ASM NUT
temperature (77°F, 25°C). Consult Derating curve for
.590 [14.99]
2X THREADED STUD
Example: At 77°F
Example:
ambient At (25°C)
77°F
temperatures the device
(25°C) the is calibrated
device
significantly ishigher
calibratedto hold
or to hold
lower than
1.009 [25.63] 1/4-28 UNF-2A at 100% of rated
atstandard
100% current
of rated (1)
current
room temperature. and
(1) trip
and at 135%
trip at of
135% rated
of rated
.284 [7.21] current (2). At
current (2).140°F (60°C),
At 140°F the same
(60°C), the same device will hold
device will hold
1.550 [39.37]
1.550 [39.37]
MAX MAX at approximately
atExample: 78%
approximately of
78% rated
of current
rated current(3), and
(3),
At 77°F (25°C) the device is calibrated trip
and at
trip at
to hold
(SEE NOTE
(SEE 1)
NOTE 1) approximately 115%
approximately of
115% rated
of current
rated (4).
current (4).
at 100% of rated current (1) and trip at 135% of rated
current (2). At 140°F (60°C), the same device will hold
1.550 [39.37]
MAX 2.429 [61.70]
2.429 [61.70]
at approximately 78% of rated current (3), and trip at
(SEE NOTE 1) 2.399 [60.93]
2.399 [60.93] approximately 115% of rated current (4).

Notes:
Notes:
2.429 [61.70]
2.399 [60.93]
1. Dimension doesdoes
1. Dimension not include sealing
not include gasket.
sealing gasket.

Notes:
1. Dimension does not include sealing gasket.

www.sensata.com
www.sensata.com 14 14
Authorised Importer and Master Distributor

www.sensata.com 14
APS USA APS Australia APS: Singapore
610 Gateway Center Way, Suites J & K U48 / 9 Vision Street, Colombia
San Diego, CA 92102 USA Wangara, WA 6065 Australia Chile
P: 1 619 263 4164 Phone: 61 (8) 9302 2369 Perú
www.aps-supply.com F: 1 619 263 6814 Fax: 61 (8) 6305 0047 Brasil

You might also like