Cios Select BV - 03-06-2020 - 152081960
Cios Select
Select smart surgical imaging
siemens-healthineers.com/cios-select
Cios Select · Technical Data
Highlights
Designed to support you in your work, What’s more, with our tightly knit s ervice network, we’re
Cios Select is your true partner on site – wherever you are around the globe.
Safeguard the financial sustainability of your clinical Select smart surgical imaging
institution with smart surgical imaging and service from
– high system availability – reliability in a smart,
a single reliable partner ‒ with Cios Select. This robust
lean design
mobile C-arm is a smart choice in every respect, featuring
a lean design, long lifecycle, and low maintenance – Smart system operation –
efforts. with an intuitive user interface
2
Technical Data · Cios Select
Highlights
3
Cios Select · Technical Data
Table of contents
Accessories
Clinical workflow
Options 13
Patient data administration 9
Exam preparation 9
Room planning
Image acquisition 9
Operating data 14
Environmental conditions (operation) 14
CARE program
Dimensions and weight 14
(Combined Applications to Reduce Exposure) 10
Dimensions in cm (inches) 15
4
Technical Data · Cios Select
System specifications
C-arm
C-arm with mechanical brakes
Orbital movement 130 ° (– 40 ° to + 90 °)
Angulation ± 190 °
Horizontal movement 20 cm (7.9”)
Immersion depth 73 cm (28.7”)
Swivel range ± 12 °
Vertical travel 42 cm (16.5”), motorized
Source to image-receptor distance 100 cm (39.4”)
Free space 78 cm (30.7”), with attached grid
Collimator system
Iris diaphragm (lead) For concentric, radiation-free collimation
Semitransparent slot diaphragm (lead) For symmetric, radiation-free collimation,
with unlimited rotation
PC Hardware
Image acquisition system Intel-compatible dual-core microprocessor with PCI bus architecture,
Windows 7, 64 bit, 8 GB RAM, S-ATA drive, USB 2.0,
high-performance and interface cards for the detector/X-ray system
Acquisition memory on hard disk Storage and postprocessing of all acquired images in a
common patient folder
150,000 images on hard disk irrespective of matrix size
Hard-disk capacity 2 TB
Power supply Integrated, uninterruptible power supply helps ensure that image
and patient data are secure in the event of a power outage
5
Cios Select · Technical Data
System specifications
6
Technical Data · Cios Select
System specifications
SIRECON 23-S3P
I.I. formats Full format Zoom 1
23 cm (9“) 16 cm (6“)
Visual resolution
Minimum value (lp/mm) 2.0 2.8 (without Cu filtration)
1.8 2.2 (with > 2 mm Cu filtration)
Conversion factor ≥ 20.5 (Cd/m ) · (s/µGy) (IEC 61262)
2
Cassette holder*
Format 24 cm x 30 cm (9.5“ x 12“)
*
Option
7
Cios Select · Technical Data
System specifications
Monitor cart
Displays
Interface description
Video splitter* 2 single-link DVI-D; female connectors;
up to 1920 x 1200 @ 60 Hz or 1080 p
USB Data interface USB 2.0
Charging interface USB 2.0
LAN Gigabit
Power cable ≥7m
Monitor cart connection cable 8.5 m
*
Option
8
Technical Data · Cios Select
Clinical workflow
Exam preparation
Applications Manager Dedicated, application-related user programs
Administration and selection of applications and application groups
Image acquisition
Operating modes Selection of application-specific fluoroscopy and radiography curves
for the individual operating modes
Fluoroscopy Image acquisition 0.5 f/s to 10 f/s; 30 f/s with continuous
fluoro mode
Image storage: all images, every nth image
Digital filtration
Moving weighted averaging for low-noise image display
with minimum dose
Optimized gray-scale visualization based on image analysis
Single Image Digital filtration
Optimized gray-scale visualization based on image analysis
Subtraction*/Roadmap* Image acquisition 0.5 f/s to 10 f/s; 30 f/s with continuous
fluoro mode
Image storage: all images, every nth image
Subtraction angiography
Peak Opacification for iodine contrast (MaxOp) and CO2 contrast
(MinOp)
Filtering of mask and fill images for contrast enhancement
Simultaneous dual-channel output for image acquisition and
postprocessing, simultaneous storage of fill image
Roadmap technique, to position a catheter precisely in a
blood vessel under fluoroscopy
IDEAL (Intelligent Dose Efficiency Algorithm) The Intelligent Dose Efficiency Algorithm (IDEAL) is a smart dose
management system specially designed for the Cios C-arm family
The result is an always optimized balance of image quality and dose
as well as automatic contrast and brightness regulation
Footswitch Standard footswitch for radiation release (10 m cable)
*
Option
9
Cios Select · Technical Data
Clinical workflow
*
Option
10
Technical Data · Cios Select
Clinical workflow
Image display/processing
Image display Aspect ratio 5:4, corresponding to 1280 x 1024 matrix,
1k x 1k image content
Split screen (1, 16 on 1)
Digital zoom, fixed zoom, roaming
Magnification (optical zoom)
Digital image rotation
Movie function for playback of scenes and auto replay function
Digital shutter
Horizontal and vertical image reversal
LSH (Last Scene Hold)
Image processing Application-specific lookup tables (LUTs) for optimum contrast and
brightness
Spatial frequency filtration for edge-enhanced image display
Edge enhancement
Noise reduction
Motion detection with active noise reduction
Metal correction
Digital Density Optimization (DDO) Digital Density Optimization reduces the dynamic range of an image,
allowing the contrast of structures to be emphasized without loss of
information in bright and dark image areas
Text/graphic functions Text: annotation, image comments, R/L marking
Graphics*: quantification with distance and angle measurements
*
Option
11
Cios Select · Technical Data
Clinical workflow
Documentation
CD/DVD DVD drive for digital image storage on CD-R, DVD+R or DVD-R
for offline data exchange in DICOM 3, TIFF and AVI formats
Printer interface* Digital printers for printing on paper or paper/film
USB export For digital image storage to a USB device in DICOM,
TIFF and AVI formats
External DVI interface* Live monitor (A):
Video splitter output for connecting an external live monitor
Reference monitor (B):
Video splitter output for connecting an external reference monitor
DVI interface (splitter), without galvanic isolation
*
Option
12
Technical Data · Cios Select
Accessories
Options
Image acquisition Subtraction/Roadmap
C-arm System-integrated laser aimer on the image intensifier 2)
Detachable grid
Cassette holder
Image display/processing Measuring of angles and distances
Data transfer and documentation DICOM Send/Storage Commitment
DICOM Print
DICOM Query/Retrieve
DICOM Worklist/MPPS
External DVI monitor connections
Printer
HIPAA
X-ray passcode
Monitor cart 19“ TFT high-brightness color display
Service Remote Desktop (Netviewer Assistance)
Accessories Sterile covers for C-arm, X-ray tube and image intensifier
2)
Class 1 (IEC 60825-1-2014), red, 635 nm, ≤ 2,97 mW
13
Cios Select · Technical Data
Room planning
Operating data
Power requirements 100 V (-6% to +10%), 50/60 Hz (± 1 Hz);
110 V, 120 V, 127 V, 200 V, 220 V, 230 V, 240 V (± 10 %),
50/60 Hz (± 1 Hz)
Unit fuse protection (internal) 100 V to 127 V 20 A slow-blow fuse
200 V to 240 V 15 A slow-blow fuse
Maximum power consumption 4.6 kW
Standby power consumption (for 230 V) 713 W
Voltage / Current values Continuous 11 A (110 V) / 5 A (230 V)
Short-time 25 A (110 V) / 20 A (230 V)
Internal line impedance Ri max. 0.3 ohms for 100 V to 127 V
Ri max. 0.8 ohm for 200 V to 240 V
1)
Option
14
Technical Data · Cios Select
Room planning
Dimensions in cm (inches)
15
On account of certain regional limitations of sales rights In the interest of complying with legal requirements
and service availability, we cannot guarantee that all concerning the environmental compatibility of our
products/services/features included in this brochure are products (protection of natural resources and waste
available through the Siemens sales organization conservation), we may recycle certain c omponents
worldwide. Availability and packaging may vary by where legally permissible.
country and are subject to change without prior notice. For recycled components we use the same extensive
quality assurance measures as for factory-new
The information in this document contains general
components.
descriptions of the technical options available and may
not always apply in individual cases. Any technical data contained in this document may vary
within defined tolerances. Original images always lose a
Siemens reserves the right to modify the design and
certain amount of detail when reproduced.
specifications contained herein without prior notice.
Please contact your local Siemens sales representative for Cios Select 144 55 031
the most current information.
Published by Siemens Healthcare GmbH · A91AT-40022-1T6-7600 · Printed in Germany · SHS AT SU 0620.pdf · © Siemens Healthcare GmbH, 06.2020