Professional Documents
Culture Documents
08ATEX0011X: LTM RPP
08ATEX0011X: LTM RPP
可能有触电、爆炸或电弧灼伤危险
不遵循上述规定将可能导致人员伤亡。
A www
.sch
neid
er-e
DA NG
lectric.c
ER
om
DA NG
ER
PE LIG
RO
DA NG
ER
PE RIC
OL O LTM
WA Rpp
RN UN
G
PE RIG
O
AAV
AAV7709
7709901-
07
02 - 901-07
2018
2014 04
1/4
Schn
35, rueeider Elec
9250 Joseph tric Indu
Fran 6 Rueil Malm Mon
ier
stries
SAS
ce
aison
www.schneider-electric.com/site/home
08ATEX0011X
1672602
B mm
in 45
1.77
(1)
2T05334
2T05334
24VDC
LV1 LV2 LV3 A1 A2 I.1 C I.2 I.3 C I.4 I.5 C I.6 97NO98 95NC96
+/~
LTMEV40FM LTMR08MBD
HMI
HMI
MR
(1)
HMI Comm
Power
Alarm
Fallback
PLC Comm
(1)
(1)
(1)
120
4.72
91
3.58
136
5.35
AAV7709901-07
AAV7709901-04 Schneider Electric Industries SAS
07
02 - 2018
2014 35, rue Joseph Monier
92506 Rueil Malmaison
1/4 France
C
1 2
2 Click!
3 4x
Rail 35 mm EN 50022, NFC 63015
75.5
2.97 75.5
2.97
1 2x
M4 x 20
4 x M4 x 20 4 4x
(# 8 x 32 )
(# 8 x 32 )
52.5
2.07
1 N.m
52.5 6 2x
8.8 Ib-in
2.07 2 2x
90°
90° 90°
180°
2T05334
24VDC
2T05334
HMI Comm
Power
Alarm
Fallback
PLC Comm
24VDC
HMI Comm
Power
Alarm
Fallback
PLC Comm
Test / Reset NO NO NO
Test / Reset
13 14 23 24 33 34 Z1 Z2 T1 T2 D1 D0 S V- NC
NO NO NO
13 14 23 24 33 34 Z1 Z2 T1 T2 D1 D0 S V- NC
LTM9TCT
97NO98 95NC96
I.6 I.6
C
I.4
I.5
C
C
I.4
I.5
C
Z1 Z2 T1 T2
I.3 I.3
I.2 I.2
C C
I.1 I.1
96
A2 A2
95 NC
A1 98 A1
97NO
S S
D0 D0
D1 D1
NO34 NO34
33 33
24 24
13 13
T2
T1
Z2
Z1
AAV7709901-07
AAV7709901-04 2/4
E2
3
E1 MLPL9999 Lug-Lug Kit
1
3 1
L N
6,8 N.m
60 lb-in
2
Click! 5
3
Click!
4
6,8 N.m
60 lb-in
E3 3 E4 3
F 1
AAV7709901-07
AAV7709901-04 3/4
G
3
A1 A2 Start Stop
KM1
7 mm 0.28 in.
LV1 LV2 LV3 A1 A2 I.1 C I.2 I.3 C I.4 I.5 C I.6 97 98 95 96
2
0.2…2.5 mm AWG 24…14
O.4
0.2…1 mm 2 AWG 24…18
LTM E LTM R
O.1 O.2 O.3
0.2…2.5 mm 2 AWG 24…14
2
0.25…2.5 mm AWG 22…14 KM1
Ø 3 mm Ø 0.125 in.
LTM R utilizzando i 3 morsetti comuni R com os 3 terminais Comum (C) с помощью 3 общих (С) клемм,
(C) collegati alla tensione di comando ligados à tensão de controlo A1 através подсоединенных к управляющему
A1 tramite filtro interno. de um filtro interno. напряжению A1 через внутренний
● Non collegare il morsetto comune (C) ● Não ligue o terminal Comum (C) às
фильтр.
● Не подсоединяйте общую (C) клемм
agli ingressi di tensione di comando entradas de tensão de controlo A1 ou
A1 o A2. A2. ко входам управляющего напряжения
A1 или A2.
Si no se respetan estas instrucciones, O não cumprimento destas instruções
Несоблюдение этих инструкций
pueden producirse daños en el pode provocar danos materiais.
может привести к повреждению
equipo.
оборудования.
97NO98 95NC96
1 A
D1
5 DGND
D0 9
4
VW3 A8 306 R●● 8
V- 7
3 B
8
2
6
1 S
D0 S V- NC VP
1
GND
CAN_H H5 LTM RpppEpp Ethernet TCP/IP
6
7
2 CAN_L
8
3 GND
4
9
5 S TD+
1
V+ TD-
RD+
RD-
97NO98 95NC96
8
AAV7709901-04
AAV7709901-07 4/4