1 2 3 4 5 6 7 8

TO 110KV TO 110KV TO 110KV


**4: TO FR LAC HOA S/S **3: TO FR VINH CHAU S/S MY XUYEN S/S **2: TO FR

E05 E04 E02


XFBCU LVT3 XFBCU LVT2 LVT1 XFBCU
XFBCU XFBCU
A BCU (6MD85) 110 0.11 0.11 0.11 0.11 BCU (6MD85) 110 0.11 0.11 0.11 0.11 110 0.11 0.11 0.11 0.11 BCU (6MD85) A
kV kV QL09 kV XFBCU
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
25 FR 25 FR 25 FR

M
TO: TARIFF METER
QE76
PMT (A1700) CL: 0.2 M
QE76 PMT (A1700) M
QE76 M
PMT (A1700)
CL: 0.2 CL: 0.2
XTV.PMT XTC.PMT XTV.PMT XTC.PMT
QL07 QL07 XTV.PMT
M QL07 M M
QE75 Wh VARh V A
Wh VARh V A Wh VARh V A XTC.PMT
QE75 QE75

CL: 3P

CL: 0.5
CL: 0.5

CL: 0.5

CL: 0.5
W VAR f ‎cosφ

CL: 0.5
W VAR f ‎cosφ W VAR f ‎cosφ

CL: 0.5
CL: 3P
M M M

CL: 3P
CL: 5P20 CL: 5P20 #2: TO F87B
TO: TARIFF METER TO: TARIFF METER CL: 5P20
*4: TO FR *3: TO FR
F67 (7SJ82) #4: TO F87B CL: 0.5 F67 (7SJ82) #3: TO F87B CL: 0.5 CL: 0.5 *2: TO FR F67 (7SJ82)
TO: TARIFF METER
XF67 XF67
XF67 TO: TARIFF METER CL: 0.2 XF67 CL: 0.2 CL: 0.2 XF67 XF67
67/67N SOTF 67/67N SOTF 67/67N SOTF

50/51 50/51N 27/59 FR TO: TARIFF METER CL: 0.5 50/51 50/51N 27/59 FR TO: TARIFF METER CL: 0.5 CL: 0.5 TO: TARIFF METER 50/51 50/51N 27/59 FR

XF87L CL: 5P20 XF87L CL: 5P20 CL: 5P20

CL: 5P20 CL: 5P20 CL: 5P20 XF87L F87L (7SL86)


F87L (7SL86) F87L (7SL86)
XF87L CT-123kV XF87L CT-123kV CT-123kV XF87L
B 68 25/79 FR/FL 87L 68 25/79 FR/FL 87L 68 25/79 FR/FL 87L B
200-400-800 400-800-1200
21/21N 67/67N 85 QF01 /1/1/1/1/1/1A 21/21N 67/67N 85 QF01 /1/1/1/1/1/1A QF01 400-800-1200 21/21N 67/67N 85
/1/1/1/1/1/1A
50/51 50/51N M 50/51 50/51N M M 50/51 50/51N
QE15 QE15 QE15
QL01 QL01 QL01
BJ-8RP VDF-10 M
BJ-8RP VDF-10 M M

F86-1, F86-2 F74-1, F74-2 QE14 F86-1, F86-2 F74-1, F74-2 QE14 BJ-8RP VDF-10
=E05+WR =E04+WR
M M F86-1, F86-2 F74-1, F74-2
=E02+WR
TO: TARIFF METER
CL: 0.2 110 0.11 0.11 0.11 0.11
QL01 M kV
3 3 3 3 3
QE15
CL: 3P CL: 3P CL: 3P
CL: 0.5 CL: 0.5 CL: 0.5
CL: 0.5
TO: TARIFF METER
CL: 5P20
CL: 0.5 TO: TARIFF METER
C CT-123kV CL: 0.2 TO: TARIFF METER C
200-300-400 CL: 0.5
=E03+CRP3 /1/1/1/1/1/1A
CL: 5P20
PMT1.E01 (A1700) CL: 5P20
BJ-8RP VDF-10 CL: 5P20
VOLTAGE CL0.2
XTV1.E01
Wh VARh V A
XTC1.E01
CT CL 0.2 F86-1, F86-2 F74-1, F74-2
E01 #1: TO F87B XFBCU
FROM E01 FROM E01 BCU (6MD85)
W VAR f ‎cosφ XF87B XF87B XFBCU
#3: FROM E04 BAY #1: FROM E01 BAY
F87B (7SS85) QF01 25 FR
#4: FROM E05 BAY #2: FROM E02 BAY
PMT2.E01 (A1700) 87B 50BF FR
XTV2.E01 XTC2.E01
VOLTAGE CL0.5 Wh VARh V A CT CL 0.5 CL: 1 PMT (A1700) XTV.PMT
FROM E01
W VAR f ‎cosφ
FROM E01
T1 CL: 5P20
XTC.PMT
Wh VARh V A

XF67
F21 (7SA82)
XF67
E03 HV-BCT
200-300-400
CL: 5P20
W VAR f ‎cosφ
/1/1/1A
67/67N 27/59 21/21N 68
PMT.E02 (A1700) 96B 96P CL: 0.5
XTV.E02 XTC.E02 50/51 50/51N SOTF FR 26W 26Q
D VOLTAGE CL0.5
FROM E02
Wh VARh V A CT CL 0.5
FROM E02 63 71Q
CL: 5P20
XF90
F90 (REG-DA)
XF90 D
W VAR f ‎cosφ XFBCU
90
BCU (6MD85) CL: 5P20
XFBCU
CL: 0.5
PMT.E04 (A1700) 25 FR
XTV.E04 XTC.E04 MV-BCT CL: 5P20 TO: J01-F67
F67 (7SJ82)
VOLTAGE CL0.5 CT CL 0.5 800-1200-1600 *1: TO FR
Wh VARh V A XF67
/1/1/1A CL: 5P20
FROM E04 FROM E04
W VAR f ‎cosφ XF67 67/67N 51/27 27/59
XFPQ 50/51 50/51N SOTF FR

**1: TO FR
PQ (PQ100)
PMT.E05 (A1700)
XTV1.E05 XTC1.E05 PQ
VOLTAGE CL0.2 Wh VARh V A CT CL 0.2 CL: 0.5 XF87T
FROM E05 FROM E05
F87T(7UT85)
CL: 3P
W VAR f ‎cosφ XFFR XFFR
*1: FROM E01 BAY **1: FROM E01 BAY -38 87T 50/51 50/51N
FR/PMU (7KE85)
*2: FROM E02 BAY **2: FROM E02 BAY CT-24KV 50REF 49 FR
PMT.E05 (A1700) FR/PMU CL: 0.5
*3: FROM E04 BAY **3: FROM E04 BAY
XTV2.E05 XTC2.E05
E VOLTAGE CL0.5 Wh VARh V A CT CL 0.5
FROM E05 *4: FROM E05 BAY **4: FROM E05 BAY
CL: 5P20 E
FROM E05
W VAR f ‎cosφ CL: 5P20

VDF-10
=E00+FR 431
J01
J0 BJ-8RP
F86-1, F86-2 F74-1, F74-2 =E01+WR

=E00+MP C41

VOLTAGE CIRCUIT

CURRENT CIRCUIT

DRAWN. BY DUC.CX TITLE: BAY No. =BASIC


110kV HOA DONG WIND POWER PLANT CONTROL, PROTECTION & MEASUREMENT PRINCIPLE
F F
B 18/06/2021 ISSUE FOR REVISION CHECKED BY HOANG.NH 110kV HOA DONG SUBSTATION R
THT TRADING, SERVICE DIAGRAM PANEL No. +
AND HIGH TECHNOLOGY
A 25/05/2021 ISSUE FOR APPROVE APPROVED BY DUNG.NT GEN. CONTRACTOR THANH DAT POWER CONSTRUCTION DESIGNING CONSULTING Co., LTD DRAWING NO.: SHEET No. B01
JOIN STOCK COMPANY
THE HIGH TECH COMPANY TD/HD-110kV/BASIC
REV. DATE JOB NUMBER: THT_HD_2021 EMPLOYER WIND POWER HOA DONG COMPANY LIMITED NEXT SHEET =E00+FR/A00

1 2 3 4 5 6 7 8