Your excellent helper in

laser distance test!


NEW!

Laser Distance Meter


INSTRUCTION MANUAL

Your excellent helper in laser distance test

NF -272L

NF -271

VER: V1
Table of Contents

Please read the complete instructions including safety Overview........................................................01


precautions before attempting any testing. 1.Display instruction.......................................02
2.Product features..........................................03
Please read all of the operational guide and safety
3.Operation instructions.................................04
regulations in this manual before operation. Improper
operations without complying with this manual guided 3.1.Turn on & off..........................................04
could cause damage to the device, influence on 3.2.Single measurement..............................04
measurement result or bodily injury to the user. 3.3.Continuous measurement......................04

The instrument is not allowed to disassemble or 3.4.Area measurement ............................... 05


repair on any ways. It is forbidden to do any illegal 3.5.Volume measurement............................05
modification or performance change for laser emitter. 3.6.Pythagorean measurement....................05
Please keep it out of reach of children and avoid using 3.7.Secondary Pythagorean measurement...06
by any irrelevant personnel.
3.8.Level measurement...............................07
It is strictly prohibited to shoot eyes or other parts 3.9.Vertical measurement............................07
of body with the laser; it is not allowed to take the laser 3.10.Addition & subtraction measurement....08
to shoot any objects' surface with strong reflecting.
3.11.Unit switching......................................08
Due to electromagnetic radiation interference to 3.12.Benchmark switching.......................... 08
other equipment and devices, please don't use the 3.13.Record query...................................... 09
meter in the plane or around medical equipment, don't
3.14.Setting............................................... 09
use it in inflammable, explosive environment.
4.Technical parameters.................................. 10
Discarded batteries or meter device shall not 5.Packing list................................................. 11
process just like household garbage, please handle 6.Error reasons and solutions......................... 11
them in line with related law and regulations.
7.Overview--Laser distance meters.................12
Any quality issues or any questions on the meter,
please contact local distributors or manufacturer in
time, we are ready to offer solutions for you.

Your excellent helper in laser distance test! Your excellent helper in laser distance test!
Overview 1.Display instruction
NF-271 designed to measure Distance,Area,
Volume,Pythagorea measurement,which is
1 9
mainly applied in indoor decoration and design,
2 10
building construction.In these basic functions,
NF-272L has upgraded many more functions, 3 11
such as Level measurement, Vertical 4 11
measurement, Voice broadcast, Degree
measurement and so on.

12
6

8
13

4
5

1 6
1 Battery condition 7 Setting
2 7
2 Beep 8 Display
3 Buzzer (271) 9 Data storage
3 Voice broadcast Data storage
(272L) 10 number (271)

1 Add 2 Subtract 4 Laser function opener Degree (272L)


3 Power & Clear 4 Measure 5 Benchmark point 11 Signal
5 Menu Benchmark & Unit Area/volume/ 12 Auxiliary indicator
6 switch 6 Pythagorean
7 Record query & setting 13 Unit

01 Your excellent helper in laser distance test! Your excellent helper in laser distance test! 02
2.Product features 3. Operation instructions

Length Area Volume


measurement measurement measurement
3.1. Turn on & off
Long press " " 2s to turn on,
Long press " " 2s to turn off.
Secondary Secondary Pythagorea
Pythagorean Pythagorean measurement
measurement ② measurement ①

NF-271

3.2. Single measurement


Press " "turn on the laser and Press "
Length Area Volume
measurement measurement measurement "again, the result will display on the
screen.
measurement
measurement

Pythagorea
Level

3.3. Continuous measurement


Secondary Secondary
Long press " " 2s to go in, the MAX & MIN
Vertical Pythagorean Pythagorean
measurement measurement ② measurement ① will shows. Press " " or " " to quit.
Besides, it will stop if no operation after 3mins.
NF-272L

03 Your excellent helper in laser distance test! Your excellent helper in laser distance test! 04
3.4. Area measurement 3.7. Secondary Pythagorean measurement "①"
Press " " to go in when the testing mode Press " " to go in when the testeing mode
in Single measurement, and Press " " to in Pythagorean measurement, then press "
get the length & width, then it will work out the " to get the ① & ② & ③ values, it will work
area on the screen. out the height "L" on the screen.



L
3.5. Volume measurement
Press " " to go in when the testing mode

in Area measurement, and Press " " to
get the length & width & height values, then it
will work out the volume on the screen.

3.6. Pythagorean measurement 3.7. Secondary Pythagorean measurement "②"


Press " " to go in when the testing mode Press " " to go in when the testeing
in Volume measurement, then press " " mode in Pythagorean measurement ①, then
to get the ① & ② values, it will work out the press " " to get the ① & ② & ③ values,
height "L" on the screen. it will work out the height "L" on the screen.



L L


05 Your excellent helper in laser distance test! Your excellent helper in laser distance test! 06
3.8. Level measurement ( ) 3.10. Addition & subtraction measurement
Pres " " to go in when the testeing mode Under the Single, Area, Volume measurement
in Pythagorean measurement ②, then press " mode, press " " to get a result "A", then
" to get the ①, it will automatically press " + " or " - ", press " " again
calculate the angle degree between the to get a another result "B", then it will auto
hypotenuse and the horizontal edge, vertical matically calculate the value ("A+B "or "A-B").
Length "H" and horizontal length "L".


H 3.11. Unit switching
0 Long press " " 2s to switch the unit,
optional from (0.000m→0.00m→0.00ft→
L 0'00''%→0.0in→0%in)

3.9. Vertical measurement( )

Pres " " to go in when the testeing mode


3.12. Benchmark switching
in Level measurement, then press " " to
go in, then press " " to get the ① & ② length, Press " " to go in, you can set the
benchmark to measure from the front side
it will work out the degree "0" and length "L".
①, or from the end side ②.

0 L

② ① ②

07 Your excellent helper in laser distance test! Your excellent helper in laser distance test! 08
3.13. Unit switching 4.Specification
Press " " to go in, you can query the
Model NF-271 NF-272L
datas measured before. Then press " "
Range 50m 70m 60m 80m 100m
" to quit.
CLEAR
or "
Acuuracy +/-1.5 mm
LCD screen FSNT with backlight
Wavelength & Output 620~680nm, <1mw
Working temperature 0~40℃
Storage termperature -20~60℃
3.14. Setting
Laser Off 30s
Press" " 2s to go in, the flashing arrow
Auto-off 2minutes
on the screen indicates that the Buzzer/Voice
Protecion level IP54
broadcast switch setting has been entered.
850mAh Lithlium
By press " + " or " - " to adjust the Power AAA
battery
Off/On. Then press " " to go volice Voice broadcast × √
calibration setting, by press " + " or " - " Degree measurement × √
adjust the parameters. Press " CLEAR
" to quit. Level measurement × √
Unit switching m/ft/in/ft+in
Benchmark switching √
Buzzer/Voice broadcast
Single measurement √
Continuous
Switch

measurement

Area measurement √
Volume measurement √
Pythagorean
Calibration √
measurement
Value Vertical measurment × √
Addition & subtraction
× √
measurement
Data storage 50 sets 99 sets
Size 119*50*26mm
Weight 100g

09 Your excellent helper in laser distance test! Your excellent helper in laser distance test! 10
5.Packing List Overview--Laser distance meters
1 Packing List 1pcs
2 Carry bag 1pcs
3 USB cable 1pcs
4 Reflector board 1pcs
5 AAA batery 3pcs
6 Manual 1pcs

7 Qualification certification 1pcs

6.Error reasons and solutions


Code Reason Solution
High or low Measure at the required
203 temperature temperature range

220 Low battery Replace new battery


Measure again in
254 Wrong calculate
correct operation

Test strong reflection


255 Weak signal
ablility of target

Don't measure under


256 Strong signal
strong light

Out of measure Measure within the


257 range range
harware error Restart, or contact dealer
300 if it happens again

11 Your excellent helper in laser distance test! Your excellent helper in laser distance test! 12