Professional Documents
Culture Documents
www.eota.eu
Centre Scientifique et
Technique du Bâtiment
84 avenue Jean Jaurès
CHAMPS-SUR-MARNE
F-77447 Marne-la-Vallée Cedex 2
Tél. : (33) 01 64 68 82 82
Fax : (33) 01 60 05 70 37
1
Official Journal of the European Communities L 254 of 08.10.1996
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 4 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
Helical end
Marking on the capsule resin : product name, bolt diameter (metric and inch), diameter and
length of the drilled hole.
Intended use :
Use category 1: Installation in dry or wet concrete and in flooded holes (depending on diameter).
Use in internal condition or external atmospheric exposure.
Temperature range: -40°C to +80°C (Max. long term temperature= +50°C).
SPIT MAXIMA
Annex A1
System Description
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 5 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
Table A1 : Materials
Type Size Material and EN/ISO reference
Capsule with methyl polymethacrilat resin, hardener and quartz sand
Cold formed steel: DIN 1654 part 2 or 4 or NF A35-053;
M8
Zinc coating 5μm min. NF E25-009
Galvanized steel
Threaded rod
s steel
SPIT MAXIMA
Annex A2
Materials and setting process
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 6 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
SPIT MAXIMA
Annex A3
Dimensions – Installation data
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 7 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
Threaded rods
hammer drilling or
compressed air drilling mode.
Static and quasi static loading, M8 to M30
in non-cracked concrete Tables C1, C2.
Use category: dry or wet concrete
(flooded holes are excluded)
Installation temperature (minimum) mortar 0°C, concrete 0°C
In-service (max long term temperature +50°C
Temperature range I: -40°C to +80°C
temperature and max short term temperature +80°C)
Base materials:
Reinforced or unreinforced normal weight concrete according to EN 206.
Strength classes C20/25 to C50/60 according to EN 206.
Design:
Anchorages are designed under the responsibility of an engineer experienced in anchorages and
concrete work.
Verifiable calculation notes and drawings are prepared taking account of the forces to be transmitted.
The position of the anchor is indicated on the design drawings (e. g. position of the anchor relative to
reinforcement or to supports, etc.).
Anchorages under static or quasi-static actions are designed in accordance with (please choose the
relevant design method): EOTA Technical Report TR 029, Edition September 2010; EN 1992-4
SPIT MAXIMA
Annex B1
Intended use – specification
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 8 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
Splitting failure
Effective anchorage depth hef [mm] 80 90 110 125 170 210 280
Partial safety factor
inst - 1,2
(Use category 1)
Partial safety factor
inst - - - 1,4 1,4 1,4 1,4 1,4
(Use category 2)
Spacing scr,N [mm] 160 180 220 250 340 420 560
scr,sp [mm] 160 230 330 450 340 420 560
Edge distance ccr,N [mm] 80 90 110 125 170 210 280
ccr,sp [mm] 80 115 165 225 170 210 280
1) resistance in concrete strength class from C20/25 to C50/60 using interpolation
SPIT MAXIMA
Annex C1
Design according to EN 1992-4
Characteristic values of resistance to tension loads
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 9 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
SPIT MAXIMA
Annex C2
Displacements
European Technical Assessment E T A - 0 3 / 0 0 0 8 Page 10 of 10 | 0 1 / 0 8 / 2 0 1 8
English translation prepared by CSTB
N0 short term [mm] 0,1 0,1 0,1 0,1 0,1 0,1 0,2
N long term [mm] 0,1 0,1 0,1 0,1 0,1 0,1 0,2
SPIT MAXIMA
Annex C3
Displacements