The X3301 is a multispectrum infrared (MIR) flame X3301 TECHNOLOGY FEATURES
5
detector. It provides unsurpassed detection of fires ▲ Complies with FM 3260
from light to heavy hydrocarbon fuels combined ▲ EN54 certified
with the highest degree of false alarm rejection. ▲ Certified SIL 2 capable
The detector has Division and Zone explosion- ▲ ATEX Directive compliant
WARRANTY proof ratings and is suitable for use in indoor and ▲ Certified performance to multiple fuel types and fire sizes
outdoor applications. ▲ EQP models available
▲ Long detection range to carbonaceous fires
The X3301 contains three IR sensors with their associated signal ▲ HART models available
processing circuitry. The standard output configuration includes ▲ FDT/DTM capable
fire alarm, fault and auxiliary relays, with an isolated 0–20 mA output ▲ Multiple sensitivity levels
model with optional HART communication. ▲ Maximum false alarm rejection
▲ Calibrated automatic optical integrity
▲ Reliable flame detection with modulated IR background
The detector provides superior performance in applications that
▲ Microprocessor controlled heated optics
are at the extremes, and where background infrared radiation is a
▲ Third-party approved options for detector verification include
normal condition:
Magnetic Optical Integrity and Manual Optical Integrity tests
— Hangars ▲ Tri-color LED indicates detector status and field-of-view (FOV)
— Offshore production platforms ▲ RFI and EMC Directive compliant
— Offshore production ships ▲ Event logging with time and date stamp
— Refineries ▲ Integral wiring compartment for ease of installation
— Production facilities ▲ Operates under adverse weather conditions and in dirty
— Loading racks environments
— Compressor stations
— Turbine enclosures BENEFITS
— Airport water curtains ▲ Single detector for multiple hydrocarbon fuels
— Automotive Painting ▲ Low cost of coverage
— LNG/LPG ▲ Ability to detect smaller fires earlier
— Gas Separation Plants ▲ Detection range of up to 125 feet for methane
— Warehousing ▲ Better detection zoning capability
— Marine ▲ Best combination of flame detection and false alarm rejection
▲ Low maintenance costs
▲ Reliable fault diagnostics
▲ Suitable for heavy industrial applications
▲ Explosion/flame proof (Ex d) or increased safety installations
(Ex d e) in hazardous locations
Fire Alarm: — Form C (NO and NC contacts) Class I, Div. 1, Groups B, C & D (T4A) DEMKO 01 ATEX 130204X
— normally de-energized Class II, Div 1, Groups E, F & G (T4A) Increased Safety Model
— latching/non-latching Class I, Div. 2 , Groups A, B, C & D (T3C) II 2 G
Fault: — Form A (NO contacts) Class II, Div 2. Groupd F & G (T3C) 0539 II 2 D
— normally energized Class III
Ex d e IIC T6...T5 Gb
— latching/non-latching Enclosure NEMA/Type 4X per NEMA 250
Ex tb IIIC T130°C
Auxiliary: — Form C (NO and NC contacts) For FM and CSA Zone approval information, T6 (Tamb – 50°C to +60°C)
— normally energized/de-energized refer to the X3301 instruction manual (95-8704) T5 (Tamb – 50°C to +75°C)
— latching/non-latching. IP66
Current Output 0–20 mA (± 0.3 mA), with a maximum loop Flameproof Model
(Optional) resistance of 500 ohms from 18–19.9 II 2 G
Vdc, 600 ohms from 20–30 Vdc 0539 II 2 D
IEC 61508
Temperature Range Operating: –40°F to +167°F (–40°C to +75°C) Certified SIL 2 Capable. Ex d IIC T6...T4 Gb
Storage: –67°F to +185°F (–55°C to +85°C) Applies to specific models – T6 (Tamb – 55°C to +60°C)
Refer to the SIL 2 Certified T5 (Tamb – 55°C to +75°C)
Hazardous location ratings from –55°C to +125°C X3301 Safety manual (95-8720) T4 (Tamb – 55°C to +125°C)
Humidity Range 0 to 95% relative humidity, can withstand 100% IP66/IP67
condensing humidity for short periods of time. RUSSIA & KAZAKHSTAN