You are on page 1of 4

INSTALLATION MANUAL

PRODUCT NAME : RAY - Pole Top Light


RAY - Pole Top Light / Double Head IP65

No. Input voltage Ordering Code


1. 220-240V 50-60Hz 7201/7233-0-3/4-505-XX
2. 7201/7233-0-3/4-507-XX
3. 7201-0-5-507-XX
4. 7201/7233-0-3/4-902-XX +
-
5. 7201/7233-0-3/4-903-XX
6. 7201-0-5-903-XX
7. 7201/7233-0-3/4-905-XX
1-9
8. 7201/7233-0-3/4-906-XX Light Emitting Diodes
9. 7201-0-5-906-XX (LED)

1 2 For aluminium pole. M12x1.75


RAY - Pole Top Light RAY - Pole Top Light / Double Head ÊíÒËÃѺàÊÒÍÅÙÁÔà¹ÕÂÁ

252
∅685 ∅685 ∅685

585 Part/ªÔé¹-A
906

Ø165
Ø 240
Ø 300
Part/ªÔé¹-B

Anchor bolt kit available separately.


ªØ´ÊÁͽ˜§¾×é¹ áÍÅ⺌ŷ ᡨíÒ˹‹ÒÂ
Ordering Code/ÃËÑÊÊÑ觫×éÍ : 9-2020-00

For galvanized steel pole.


Part/ªÔé¹-C ÊíÒËÃѺàÊÒàËÅç¡¡ÑÅÇÒ乫 ∅3/4"-10UNC
300

4000 The poles are


available separately
200
300

as accessories.
àÊÒ á¡¨íÒ˹‹ÒÂ
200
300

1000

Anchor bolt kit available separately.


ªØ´ÊÁͽ˜§¾×é¹ áÍÅ⺌ŷ ᡨíÒ˹‹ÒÂ
Ordering Code/ÃËÑÊÊÑ觫×éÍ : 9-2023-00
Total weight including pole/¹éíÒ˹ѡÃÇÁàÊÒ : 25 Kg./¡¡.

Last Revised On : 21/12/2020 REV.01


1/4 FR-DM-17 REV.03 EFF 15/09/17
3 4 5 Cable length 1.20 m.
ÊÒÂä¿ÂÒÇ 1.20 àÁµÃ
3.3
3.1
4.2
3.2
52

4.1

3.4 3.5

Part/ªÔé¹-C

6 7 8
Fuse L N

L
N
Surge

12

6 25

6 30
Cable size : 3x1.00 mm .2 ∅ 6-10mm.
Torque/áçºÔ´ : 36.5 Nm. ¢¹Ò´ÊÒÂä¿

9 10 11

9.1

9.2

Torque/áçºÔ´ : 2.5 Nm.

Last Revised On : 21/12/2020 REV.01


2/4 FR-DM-17 REV.03 EFF 15/09/17
12 13 Torque/áçºÔ´: 1.0 Nm
13.3
12.1

13.2
Part/ªÔé¹-A

12.2
13.1

Control Gear Weight


¹éíÒ˹ѡ ªØ´ÍØ»¡Ã³¤Çº¤ØÁ
0.8 Kg./¡¡.

Part/ªÔé¹-B

14 14.3 15

Torque/áçºÔ´ : 9 Nm. - Footstall dimension can be


A calculated according to your
Country norms and ground
14.2 14.1 B
properties.¢¹Ò´ฐÒ¹¤Í¹¡ÃÕµ ¢Öé¹ÍÂً¡Ñº
E ¤Ø³ÊÁºÑµÔ ¢Í§¾×é¹´Ô¹ ¢Í§áµ‹áÅлÃÐà·È
A B C D E
C D 35 Cm. 35 Cm. 70 Cm. 70 Cm. 90 Cm.
Cable Conduit/ ·‹ÍÌÍÂÊÒÂä¿

Installation complete
µÔ´µÑé§àÊÃç¨ÊÁºÙó

Remark : Warning :
ËÁÒÂà赯 ¢ŒÍ¤ÇÃÃÐÇѧ
1. Installation should be carried out by a qualified 1. The manufacturer will not be liable or held responsible
electrician in accordance with appropriate national for any incorrect installation, misuse or improper use
wiring regulation. and unauthorised modification to the fittings. Failure
¡ÒõԴµÑé§â¤Áä¿¿‡ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´Âª‹Ò§ä¿¿‡Ò ·ÕèÁÕ to comply with mentioned warning may cause serious
¤ÇÒÁÃٌáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿‡Ò â´Â੾ÒеÒÁ damage or serious injury to persons, animals or
ÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿‡Ò objects. If any modification is required please consult
2. Disconnect the power before changing the lamp. your dealer for the details.
»´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ ·Ò§¼ÙŒ¼ÅÔµäÁ‹ÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒÃ
3. This is Class1 luminaire, the installation must be µÔ´µÑé§äÁ‹¶Ù¡ÇÔ¸Õ, 㪌§Ò¹¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ
completed with earthing. «Öè§ ÊÔ觼Դ»¡µÔàËŋҹÕé ÍÒ¨·íÒãˌà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊѵǏ ÊÔ觢ͧ
â¤Áä¿Ã؋¹¹Õé¶Ù¡¨Ñ´änj㹻ÃÐàÀ·¢Í§¡Òû‡Í§¡Ñ¹ä¿¿‡ÒÃÑèÇ ÃдѺ 1 ·Õè¨Ð ËÒ¡ÁÕ¢ŒÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµŒÍ§¡ÒûÃѺᵋ§µÑÇâ¤Á ãˌàËÁÒÐÊÁ¡Ñº
µŒÍ§µ‹ÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ ¡ÒÃ㪌§Ò¹ ¡ÃسҵԴµ‹ÍµÑÇá·¹¨íÒ˹‹ÒÂËÃ×ͼٌ¼ÅÔµ
4. Do not exceed the maximum wattage. 2. Where damage has occured to the fittings, please
ˌÒÁ㪌ËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡Ç‹Ò·ÕèÃÐºØ ËÃ×Í㪌ËÅÍ´¼Ô´»ÃÐàÀ· make the replacement with standard parts before use.
5. Don't touch LED while maintaining or cleaning. 㹡óշÕèÁÕªÔé¹Ê‹Ç¹»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕ蹪Ôé¹
ˌÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ ʋǹãËÁ‹¡‹Í¹¡ÒÃ㪌§Ò¹·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑÂ

Last Revised On : 21/12/2020 REV.01


3/4 FR-DM-17 REV.03 EFF 15/09/17
Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm.2 Ø6-10 mm.

Do not touch the LED because it may shorten the life time or the LED can be
NO breaking down.
ˌÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãˌËÅÍ´àÊ×è ÍÁÊÀÒ¾

Any damaged safety glass cover must be replaced only with the original
spare part.
àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËŋ᷌¨Ò¡¼ÙŒ¼ÅԵ෋ҹÑé¹

NO Not using chemical compounds and aggressive agents such as , weed repellents
fertilizers , acid solvent and contaminated irrigation water near the Luminaires.
ˌÒÁ㪌ÊÒÃà¤ÁÕઋ¹ »Ø‰Â , ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໚¹¡Ã´ áÅйéíÒ»¹à»„œÍ¹ÊÒÃà¤ÁÕ
ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿

Environmental protection: Waste electrical products should not be disposed of


with household waste. please recycle where facilities exist.check with your local
authority or retailer for recycling advice.
ˌÒÁ·Ô駼ÅÔµÀѳ±¹ÕéËÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æ àÁ×èÍÊÔé ¹ÊØ´ÍÒÂØ¡ÒÃ㪌§Ò¹ â»Ã´á¡¼ÅÔµÀѳ±
ÍÍ¡¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æ áÅÐÃÕä«à¤ÔÅÍ‹ҧàËÁÒÐÊÁ à¾×èÍʋ§àÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪌«éíÒ «Öè§
¨Ðª‹Ç»‡Í§¡Ñ¹ÍѹµÃÒµ‹ÍÊÔè§áǴŌÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹Øɏ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁ‹ÁÕ¡ÒäǺ¤ØÁ

For 1-10V dimming and DALI system.


ÊíÒËÃѺÃкº´ÔÁ1-10VáÅÐÃкºDALI Green/Yellow :
A = 38-40 mm. Brown : L
B = 8-10 mm. Blue : N
C = 30-32 mm. C B White : +
A Black : - For DALI System
2
Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm. Ø6-10 mm. ÊíÒËÃѺÃкº DALI
2:- DA2

16A Fuse 1:+ DA1

N
1 ...1 0 V
-

-
1...10 V
+

To Luminaire./ࢌÒâ¤Áä¿ 10kV Surge Protector From input./ÊíÒËÃѺÊÒÂࢌÒ


L

Last Revised On : 21/12/2020 REV.01


4/4 FR-DM-17 REV.03 EFF 15/09/17