You are on page 1of 6

SIRC V-series Compressed Air Solution

Innovation · Efficiency · Reliability

Distributed by: A Completely New Generation


Rotary Screw Air Compressor

We are committed to using environmentally conscious print practices that reduce waste. SN: MH-0500116-EN
Modular Design, High Efficiency, Easy to Service

Integrated High Efficiency Compression Module User Friendly Control System


The compression module and coolant separation system are integrated into a single The controller has complete functions for self-diagnostics and protections
package to minimize connection points and leakage thus increasing efficiency to minimize downtime
Spin-on oil filter and separator element are easy to replace Built-in RS-485 communication port supports MODBUS RTU protocol,
Air filter, oil filter and separator element are easily accessible for services allows customer to connect the machines for monitoring control remotely

Premium Poly-V Belt-drive System


Premium Poly-V belt provides uniform bearing load and belt wear pattern to extend
life of belt
Patented automatic belt tensioning mechanism maximums simplicity and reliability
Separate belt pulley area, safe and easy to maintain Advanced Cooling System
5.5-11kW: Oversized combination cooler with roof mount discharge for
greater efficiency and ease of ducting.
Integrated centrifugal fan with two-axis main motor saved power
consumption of a separate fan motor.
15-37kW: Patented blower arc-housing profile design and eccentrical-
ly-positioned fan motor design greatly improve the stability, cooling
efficiency and reduce sound level.

Belt-driven Model: 5.5-37kW


Hot box / Cold box Design
Unique Hot box/ Cold box design keep the heat out of the package and noise in.
All of the components that generate heat are put together on the “hot box” in order
to concentrate maximum air flow and sound attenuation where they are needed most
The motor, electrical components and cooler are isolated from the heat of the air-end
in order to extend motor and electrical components life and provide enhanced cooling

03 04
Reliability, Integration, Excellence Performance

Highly Integrated Air Intake and Oil Separation System High Efficient Oil Separation System
Modular design integrates piping and sensors reduce 15% connecting points compared with similar products which eliminate leakage High-quality air delivered through high-efficiency oil separation system
The inlet module integrates inlet filter, inlet valve and solenoid valve. This improves air intake efficiency and stability. allows less than 3ppm carryover

Oil separation module integrate oil filter and thermal control valve. It maintains a constant oil temperature to keep water from condensing in low Patented two stage conical baffle separator minimizes coolant carryover to
flow and low ambient conditions. your plant and reduces the amount of make-up replaced.
Safe, easy maintenance via removable hinged doors, swing out separator lid
and orifice fitting with sight glass

High Efficient Cooling System All major fittings are using Viton O-ring face seal to eliminate leakage

Air-cooled: Bolted oil cooler and after cooler improve reliability and efficiency
·Eliminate thermal stresses to avoid cooler failure and leakage
·Avoid heat exchange between the two coolers to improve cooling efficiency
·Ducting hole and space reserved to facilitate cleaning on coolers
Water-cooled: Horizontal shell-and-tube heat exchanger
·The tubes is easily removable for cleaning
·Integrated water valve to adjust water volume according to environment temperature

Maintenance-free Drive System


Superior Airend with patented coolant dam insures clean oil under any and
all conditions especially during start-up. Line contact of duplex tapered roller
bearings for thrust loads dramatically improve airend life
Integral gearbox reduces windage losses and protects against damaging dirt
Intelligent Controller and moisture
Large high definition LED screen clearly display compressor status. User friendly interface is IP55 protection grade high-efficient motor with Class F insulation and a
easy to use for checking and adjusting parameters. Class B rise ensures long motor life
Built-in RS-485 communication port supports MODBUS RTU protocol, allows customer to For VSD models, both main motor and fan motor are variable speed
control machines remotely and sequencing multiple units. controlled that maximizes energy efficiency. Advanced cooling method
Gear-driven Model: 45-160kW designed for VSD motor ensures reliability when motor is working at low
PORO function ensures the machine to restore operation
automatically after a sudden power off condition. speed condition.

Powerful self-diagnostics and protection functions reduce


downtime. Maintenance alert function helps to monitor
service time of consumables and remind you to do proper
maintenance on time.

05 06
Fixed-speed 50hz Performance Variable-speed 50hz Performance
Pressure Motor Power Flow Capacity Noise Level Dimension (mm) Weight Pressure Motor Power Flow Capacity Noise Level Dimension (mm) Weight
Model Model
barg kW m3/min dB(A) Length Width Height Kg barg kW m3/min dB(A) Length Width Height Kg
V5-7 7 0.83 V15-7VSD 7.5 0.98-2.50
V5-8 8 5.5 0.78 72 826 759 782 245 0.89-2.42
V15-8VSD 8.5
V5-10 10 0.70 15 66 1295 870 1125 580
V15-10VSD 10 0.76-2.12
V7-7 7 1.10
V7-8 8 7.5 1.03 72 826 759 782 245 V15-12VSD 12 0.60-1.65
V7-10 10 0.91 V18-7VSD 7.5 1.19-3.10
V11-7 7 1.63 V18-8VSD 8.5 1.12-3.00
18.5 66 1295 870 1125 580
V11-8 8 11 1.52 72 826 759 782 245 V18-10VSD 10 1.01-2.60
V11-10 10 1.35
V18-12VSD a 0.79-2.20
V15-7 7 2.50
V15-8 8 2.40 V22-7VSD 7.5 1.28-3.70
15 66 1295 870 1125 540
V15-10 10 2.10 V22-8VSD 8.5 1.13-3.50
22 66 1295 870 1125 580
V15-12 12 1.70 V22-10VSD 10 0.98-3.10
V18-7 7 3.10 V22-12VSD 12 0.89-2.50
V18-8 8 3.00
18.5 66 1295 870 1125 625 V30-7VSD 7.5 2.12-5.50
V18-10 10 2.60
V30-8VSD 8.5 2.00-5.20
V18-12 12 2.20 30 69 1654 1277 1232 1080
V22-7 7 3.70 V30-10VSD 10 1.85-4.80
V22-8 8 3.50 V30-12VSD 12 1.60-4.20
22 66 1295 870 1125 620
V22-10 10 3.10 V37-7VSD 7.5 2.37-6.20
V22-12 12 2.50
V37-8VSD 8.5 2.31-6.00
V30-7 7 5.50 37 69 1654 1277 1232 1080
V37-10VSD 10 2.20-5.70
V30-8 8 5.20
30 69 1654 1277 1232 1040 V37-12VSD 12 1.93-5.00
V30-10 10 4.80
V30-12 12 4.20 V45-7 VSD 7 2.90-7.60
V37-7 7 6.20 V45-8 VSD 8 45 2.70-7.30 75 2367 1234 1548 1540
V37-8 8 6.00
37 69 1654 1277 1232 1060 V45-10 VSD 10 2.50-6.50
V37-10 10 5.70
V55-7 VSD 7 4.10-10.50
V37-12 12 5.00
V45-7 7 7.60 V55-8 VSD 8 3.60-9.40
55 75 2367 1234 1548 1580
V45-8 8 45 7.30 75 2367 1234 1548 1519 V55-10 VSD 10 3.20-8.30
V45-10 10 6.50 V55-11 VSD 11.4 2.90-7.60
V55-7 7 10.50 V75-7 VSD 7 5.10-13.40
V55-8 8 9.40
55 75 2367 1234 1548 1552 V75-8 VSD 8 4.80-12.50
V55-10 10 8.30 75 75 2367 1234 1548 1660
V55-11 11.4 7.60 V75-10 VSD 10 4.30-11.00
V75-7 7 13.40 V75-11 VSD 11.4 4.00-10.20
V75-8 8 12.50 V90-7 VSD 7 6.50-17.10
75 75 2367 1234 1548 1642
V75-10 10 11.00 V90-8 VSD 8 5.90-15.60
V75-11 11.4 10.20 90 76/73 3171 1574 1903 2695/2810
V90-10 VSD 10 5.30-14.00
V90-7 7 17.10
V90-12 VSD 12 4.60-12.30
V90-8 8 15.60
90 76/73 3171 1574 1903 2660/2775 V110-7 VSD 7 7.80-20.50
V90-10 10 14.00
V90-12 12 12.30 V110-8 VSD 8 7.40-19.60
110 76/73 3171 1574 1903 2710/2830
V110-7 7 20.50 V110-10 VSD 10 6.60-17.50
V110-8 8 19.60
110 76/73 3171 1574 1903 2695/2810 V110-12 VSD 12 5.80-15.40
V110-10 10 17.50
V132-7 VSD 7 9.20-24.10
V110-12 12 15.40
V132-7 7 24.10 V132-8 VSD 8 8.60-22.80
132 76/73 3171 1574 1903 2730/2850
V132-8 8 22.80 V132-10 VSD 10 8.10-21.00
132 76/73 3171 1574 1903 3085/3200
V132-10 10 21.00 V132-12 VSD 12 7.00-18.50
V132-12 12 18.50
V160-7 VSD 7 11.00-29.20
V160-7 7 29.20
V160-8 VSD 8 10.50-27.30
V160-8 8 27.60 160 76/73 3171 1574 1903 3270/3325
160 76/73 3171 1574 1903 3250/3295 V160-10 VSD 10 9.50-25.00
V160-10 10 25.00
V160-12 12 22.00 V160-12 VSD 12 8.30-22.00

·Air capacity is tested as per standard ISO1217 annex C ·Air capacity is tested as per standard ISO1217 annex C
·Noise level is tested as per standard ISO 2151: 2004 annex C, deviation 3dB (A) ·Noise level is tested as per standard ISO 2151: 2004 annex C, deviation 3dB (A)
·Inlet air temperature data is acquired outside package enclosure; discharge capacity is acquired at discharge point outside package enclosure; discharge pressure is acquired at discharge point outside package enclosure ·Inlet air temperature data is acquired outside package enclosure; discharge capacity is acquired at discharge point outside package enclosure; discharge pressure is acquired at discharge point outside package enclosure
·After symbol *“/”is water-cooled package parameter ·After symbol *“/”is water-cooled package parameter
·Maximum working pressure can reach up to 0.5barg above the rated pressure. ·Maximum working pressure can reach up to 0.5barg above the rated pressure.

07 08
The Importance of Air Quality Air Filter
Providing clean, dry, compressed air is especially important in applications where moisture or contamination can cause system Working Principle
corrosion, damage to air-powered tools or degradation of products or processes touched by the compressed air. Compressed air goes through filter and has interception, inertial collision and adsorption effects with respect to certain filter
elements. Oil, solid particulate and odor are removed which ultimately will produce high quality compressed air.

Product Details
Aluminium alloy cast housing, compact in structure
Pressure Controller Filter element with stainless steel inner/outer supporting mesh, and strong filtering capability
Particulate
Low pressure-drop design, easy to install and maintain
Receiver Vapor Filter Vapor
Particulate Filter
Dryer Oil Filter G, H, D, A four filter types available
Oil
Air Compressor G – Main purpose filter, able to remove particulate above 1µm and moisture/oil mist, with a moisture-removing
Caustic gases
Oil/Water Separator efficiency above 95%.
Drain Traps
H – High efficiency filter, able to remove particulate above 0.01µm and moisture/oil mist, with oil carryover
0.01ppm@7Barg
D – Dust filter, to remove dust particulate larger than 0.01µm.
SIRC offers industry-leading products and solutions that enable businesses around the world to reduce energy consumption A – Activated carbon filter, to remove dust particulate larger than 0.01µm and moisture/oil mist, with oil carryover less
than 0.001mg/m3
and costs and decrease harmful environmental emissions.
With an understanding of your industry classification requirements, SIRC can provide the optimal air treatment equipment for Working Standard
your system and you’ll continue to enjoy reduced costs and increased productivity.
Working medium: compressed air or non-corrosive gases Rated working pressure: 7 Bar
Air inlet temperature: ≤80℃ Maximum working pressure: 10 Bar

ISO specifies purity classes of compressed air with respect to particles, water and oil. Compressed Air Filter Performance
ISO 8573-1:2010 Air Quality Classes Capacity Dimension (mm) Weight
Model Connection
Solid Particulate Water Oil m /min
3
H D (kg)
ISO 8573-1: Mass Vapour F42V(*) 0.7 0.5" BSPT 225 89 0.9
Maximum number of particles per m3 Total Oil (aerosol liquid and vapour)
2010 CLASS Concentration Pressure F72V(*) 1.2 0.5" BSPT 225 89 0.9
mg/m3
0.1-0.5 micron 0.5-1 micron 1-5 micron mg/m3 Dewpoint
F108V(*) 1.8 0.5" BSPT 258 89 1
1 ≤20,000 ≤400 ≤10 - ≤-70℃ 0.01 F216V(*) 3.6 0.75" BSPT 333 120 2.4
F294V(*) 4.9 1" BSPT 432 120 2.9
2 ≤400,000 ≤6,000 ≤100 - ≤-40℃ 0.1
F342V(*) 5.7 1" BSPT 432 120 2.9
3 - ≤90,000 ≤1,000 - ≤-20℃ 1 F390V(*) 6.5 1.5" BSPT 432 120 3
4 - - ≤10,000 - ≤+3℃ 5 F444V(*) 7.4 1.5" BSPT 432 120 3
F540V(*) 9 1.5" BSPT 432 120 3
5 - - ≤100,000 - ≤+7℃ -
F690V(*) 11.5 2" BSPT 521 162 5.1
6 - - - ≤5 ≤+10℃ - F810V(*) 13.5 2" BSPT 521 162 5.1
F990V(*) 16.5 2" BSPT 845 160 6.5
F1050V(*) 17.5 2" BSPT 845 160 6.6
To determine which classification you require for your applications, below are some typical quality classes recommended. F1170V(*) 19.5 2" BSPT 845 160 6.6
F1380V(*) 23 2.5" BSPT 601 200 8.7
F1590V(*) 26.5 2.5" BSPT 601 200 8.7
Typical Quality Classes Typical Quality Classes F1740V(*) 29 2.5" BSPT 601 200 8.7
Applications Applications F2100V(*) 35 3" BSPT 862 200 11
Solid Particulate Water Oil Solid Particulate Water Oil
F2340V(*) 39 3" BSPT 862 200 11
Air agitation 5 3 3 Pneumatic cylinders 3 5 3 F2700V(*) 45 4"FLG 900 470 66
F3090V(*) 51.5 5"FLG 900 470 98
Air bearings 2 3 2 Pneumatic tools 4 4 4
F3480V(*) 58 5"FLG 900 470 103
Air gauging 3 3 2 Process control instruments 2 3 2 F4080V(*) 68 5"FLG 930 520 118
Air motors 4-1 5 4 Paint spraying 3 3 3 F4200V(*) 70 5"FLG 930 520 120
F4560V(*) 76 5"FLG 930 520 120
Cleaning of machine parts 4 4 4 Sand blasting 3 3 /
F4800V(*) 80 6"FLG 930 520 123
Conveying, granular products 4 3 3 Welding machines 4 5 4 F5520V(*) 92 6"FLG 1020 580 125
F5940V(*) 99 6"FLG 1020 580 125
Conveying, powder products 3 2 2 General workshop air 4 5 4
F7680V(*) 128 6"FLG 1080 640 148
Fluidics, sensors 2-1 2 2 Mining 5 5 4 F8700V(*) 145 6"FLG 1080 640 180
Foundry machines 4 5 4 Micro-electronics manufacture 1 1 1 *G, H, D, A four filter types available, performance is in accordance with ISO 8573-1

Food & beverages 3 1 2 Packaging and textile machines 3 3 4

Hand operated tools 5-4 5-4 4 Photographic film processing 1 1 1


Common Options
Model Working Pressure > 10 Bar Differential Pressure Gauge Flowmeter Electronic Drain Valves Stainless Steel Housing
Filter √ √ √ √ √

09 10
Refrigerated Compressed Air Dryer Refrigerated Compressed Air Dryer

Air Outlet

Gas water

Compressor
separator
Separator
Working Principle Product Details

Moisture
Air Inlet
Hot gas bypass valve
A refrigerated dry is used for removing water vapor from Unique triple-chamber-type heat exchanger design for high efficiency and energy saving.
compressed air. The refrigerant cools down the compressed Cold air chambers are completely separated from the hot air chambers, ensuring the evapo-
air and condense the water vapor into droplets afterwards rating peak temperature loss is minimized.

Electronic Drain
separate it from the compressed air. Brand new aluminum alloy material with completely corrosion proof through an anodizing
process for the heat exchanger avoids failures and leakages.
Expansion valve Air-cooled Condenser
Pre-cooler, evaporator, and interior piping all fitted with copper piping to avoid corrosion,
Refrigerated Dryer Schematic
ice block and interior leakage issues.
Working Standard Top venting condenser for air-cooled models is in compliance with aerodynamics. Convec-
Air flow: 0.7-145 m3/min Air inlet temperature: ≤45℃ tion of air is crucial to operation all the time to ensure constant performance in even the
harshest environments.
Rated working pressure: 7 Bar Ambient temperature: 40℃, water inlet temperature 30℃,
Vortex gas/water separator is standard on all refrigerated air dryers, which effectively
Maximum working pressure: 10 Bar Pressure dew point: 7℃
eliminates over 99% of liquid in the air stream.
Standard equipped environmentally friendly refrigerant and remote control
Technical Specification - 50 Hz
Refrigerated Dryer Specification Technical Specification - 50 Hz
Capacity Voltage Dimension (mm) Weight Condensate Refrigerated Dryer Specification
Model Connection Drain
m3/min V/Ph/hz L W H kg Connection Capacity Voltage Dimension (mm) Weight Condensate
Model Connection Drain
Air-cooled m /min
3
V/Ph/hz L W H kg Connection
D42VNRi-A-E 0.7 220/1/50 0.75" BSPT 520 400 580 46 DN8 Water-cooled
D72VNRi-A-E 1.2 220/1/50 1" BSPT 560 400 600 61 DN8 D690VNRi-W-E 11.5 380/3/50 2" BSPT 1080 720 1020 255 DN8
D108VNRi-A-E 1.8 220/1/50 1.5" BSPT 630 430 650 72 DN8 D810VNRi-W-E 13.5 380/3/50 2" BSPT 1180 750 1020 288 DN8
D216VNRi-A-E 3.6 220/1/50 1.5" BSPT 725 520 810 102 DN8 D990VNRi-W-E 16.5 380/3/50 2.5" BSPT 1180 750 1020 297 DN8
D294VNRi-A-E 4.9 220/1/50 1.5" BSPT 725 520 810 102 DN8 D1050VNRi-W-E 17.5 380/3/50 2.5" BSPT 1420 800 1200 376 DN8
D342VNRi-A-E 5.7 220/1/50 1.5" BSPT 725 520 810 133 DN8 D1170VNRi-W-E 19.5 380/3/50 3" FLG 1550 800 1250 442 DN8
D390VNRi-A-E 6.5 220/1/50 1.5" BSPT 725 520 810 135 DN8 D1380VNRi-W-E 23 380/3/50 4" FLG 1650 800 1300 502 DN8
D444VNRi-A-E 7.4 220/1/50 1.5" BSPT 854 614 960 177 DN8 D1590VNRi-W-E 26.5 380/3/50 4" FLG 1650 800 1300 505 DN8
D540VNRi-A-E 9 380/3/50 1.5" BSPT 950 750 1340 207 DN8 D1740VNRi-W-E 29 380/3/50 4" FLG 1750 860 1300 572 DN8
D690VNRi-A-E 11.5 380/3/50 2" BSPT 1050 750 1340 246 DN8 D2100VNRi-W-E 35 380/3/50 4" FLG 1700 1140 1320 648 DN8
D810VNRi-A-E 13.5 380/3/50 2" BSPT 1175 800 1345 273 DN8 D2340VNRi-W-E 39 380/3/50 4" FLG 1700 1160 1450 696 DN8
D990VNRi-A-E 16.5 380/3/50 2.5" BSPT 1255 880 1345 298 DN8 D2700VNRi-W-E 45 380/3/50 5" FLG 1820 1160 1500 762 DN8
D1050VNRi-A-E 17.5 380/3/50 2.5" BSPT 1420 900 1520 365 DN8 D3090VNRi-W-E 51.5 380/3/50 5" FLG 1800 1240 1550 875 DN8
D1170VNRi-A-E 19.5 380/3/50 3" FLG 1550 900 1520 425 DN8 D3480VNRi-W-E 58 380/3/50 5" FLG 1900 1240 1550 977 DN8
D1380VNRi-A-E 23 380/3/50 4" FLG 1700 900 1520 492 DN8 D4080VNRi-W-E 68 380/3/50 6" FLG 1900 1240 1820 1188 DN8
D1590VNRi-A-E 26.5 380/3/50 4" FLG 1700 900 1520 498 DN8 D4200VNRi-W-E 70 380/3/50 6" FLG 1900 1240 1820 1276 DN8
D1740VNRi-A-E 29 380/3/50 4" FLG 1800 980 1600 540 DN8 D4560VNRi-W-E 76 380/3/50 6" FLG 2560 1630 1830 1645 1"
D2100VNRi-A-E 35 380/3/50 4" FLG 1700 1140 1520 613 DN8 D4800VNRi-W-E 80 380/3/50 6" FLG 2560 1630 1830 1678 1"
D2340VNRi-A-E 39 380/3/50 4" FLG 1750 1160 1570 659 DN8 D5520VNRi-W-E 92 380/3/50 6" FLG 2560 1630 1830 1822 1"
D2700VNRi-A-E 45 380/3/50 5" FLG 1820 1160 1570 726 DN8 D5940VNRi-W-E 99 380/3/50 6" FLG 2560 1630 1830 1855 1"
D3090VNRi-A-E 51.5 380/3/50 5" FLG 1900 1240 1750 829 DN8 D7680VNRi-W-E 128 380/3/50 8" FLG 3100 1700 2050 2180 1"
D3480VNRi-A-E 58 380/3/50 5" FLG 2100 1240 1750 915 DN8 D8700VNRi-W-E 145 380/3/50 8" FLG 3100 1700 2050 2368 1"
D4080VNRi-A-E 68 380/3/50 6" FLG 2100 1240 1650 1100 DN8
·Pressure Dewpoint is in accordance with ISO 8573-1 Class 5
D4200VNRi-A-E 70 380/3/50 6" FLG 2100 1240 1650 1233 DN8 ·Data refers to the following conditions: ambient temperature 40℃, water inlet temperature 30℃, air inlet temperature 45℃, air inlet pressure: 7 barg

D4560VNRi-A-E 76 380/3/50 6" FLG 2570 1800 1850 1396 1"


D4800VNRi-A-E 80 380/3/50 6" FLG 2570 1800 1850 1430 1"
Common Options
D5520VNRi-A-E 92 380/3/50 6" FLG 2570 1800 1850 1800 1"
D5940VNRi-A-E 99 380/3/50 6" FLG 2570 1800 1850 1800 1"
Model Working pressure > 10 bar High Temperature: 80℃ PLC Display Stainless Steel Heat Exchanger Dew Point Control

D7680VNRi-A-E 128 380/3/50 8" FLG 3100 2070 2050 2100 1" Refrigerated Dryer √ √ √ √ √
D8700VNRi-A-E 145 380/3/50 8" FLG 3100 2070 2050 2100 1"

·Pressure Dewpoint is in accordance with ISO 8573-1 Class 5


·Data refers to the following conditions: ambient temperature 40℃, water inlet temperature 30℃, air inlet temperature 45℃, air inlet pressure: 7 barg