You are on page 1of 2
TECHNICAL DATA SHEET 0 TEMPERATURE TRANSMITTER 8312-120-0 This sensor measures the temperature inthe alr conditioning ducts of the cabin and the cockpit. ‘The temperature measuring component is a precision thermistor. SPECIFICATIONS Current in sensitive element : Ss 2mA Range o-71°C Extreme temperature range =85°Cto + 120°C Tolerance from 0 to 80°C from -55 100°C from 80 to 120°C = Weight 909 TESTING Required equipment — = _ Environmental chamber Metal mass (P/N 653030-143) Standard platinum RTD Digital thermometer operating with RTD ; resolution + 0,1 °C Digital ohmmeter, 4 1/2-digit (20,000 counts) ; measuring current 100A and 10 “A 21-63-15 Brion Leroux — F0213 2 et 4 rue Isaac Newton 93152 Le Blanc Mesnil March 1991 OHMMETER UNDER TEST METAL MASS(M) PLATINUM RTD (S) (7) ft THERMOMETER ENVIRONMENTAL CHAMBER (E) Connect the test circutt. Connect the chmmeter between pins A and G of the transmitter connector. Bring the temperature of the environmental chamber (E) to the various levels shown in the table below ; allow temperature to stabilize for 30 minutes before each measurement. Check that the chmmeter reading is between the minimum and maximum values shown in the table. ‘TEST TEMPERATURE 100 470 124 READING ING 237 18 107 wi | aa | ae COHMMETER RANGE Gun | doun | Woon STORAGE This transmitter must be stored in its original packaging away from corrosive fumes and moisture. REMOVAL FROM STORAGE The transmitters should be taken out of storage only at the time of installation. ‘Check accuracy before installing. MORS BRION LEROUX Fo213 2-4 rue Isaac Newton 93152 LE BLANC MESNIL