TECHNICAL DATA SHEET
0 TEMPERATURE TRANSMITTER
8312-120-0
This sensor measures the temperature inthe alr conditioning ducts of the cabin and the cockpit.
‘The temperature measuring component is a precision thermistor.
SPECIFICATIONS
Current in sensitive element : Ss 2mA
Range o-71°C
Extreme temperature range =85°Cto + 120°C
Tolerance from 0 to 80°C
from -55 100°C
from 80 to 120°C =
Weight 909
TESTING
Required equipment
— = _ Environmental chamber
Metal mass (P/N 653030-143)
Standard platinum RTD
Digital thermometer operating with RTD ; resolution + 0,1 °C
Digital ohmmeter, 4 1/2-digit (20,000 counts) ; measuring current 100A and 10 “A
21-63-15
Brion Leroux — F0213
2 et 4 rue Isaac Newton
93152 Le Blanc Mesnil March 1991OHMMETER UNDER TEST METAL MASS(M)
PLATINUM
RTD (S)
(7) ft
THERMOMETER
ENVIRONMENTAL CHAMBER (E)
Connect the test circutt.
Connect the chmmeter between pins A and G of the transmitter connector.
Bring the temperature of the environmental chamber (E) to the various levels shown in the table
below ; allow temperature to stabilize for 30 minutes before each measurement.
Check that the chmmeter reading is between the minimum and maximum values shown in the table.
‘TEST TEMPERATURE 100
470 124
READING
ING
237 18 107
wi | aa | ae
COHMMETER RANGE Gun | doun | Woon
STORAGE
This transmitter must be stored in its original packaging away from corrosive fumes and moisture.
REMOVAL FROM STORAGE
The transmitters should be taken out of storage only at the time of installation.
‘Check accuracy before installing.
MORS
BRION LEROUX
Fo213
2-4 rue Isaac Newton
93152 LE BLANC MESNIL