You are on page 1of 7

Skurka Aerospace Inc.

4600 Calle Bolero


Camarillo, CA 93012

SERVICE BULLETIN
SUBJECT: Upgrade of Starter Generator Model 200SGL147Q-4 to 200SGL147Q-6

AFFECTS: Starter Generator Model 200SGL147Q-4, All Serial Numbers

1. SUMMARY

This Service Bulletin gives instructions on upgrading starter generator model 200SGL147Q-4 to
200SGL147Q-6.

2. PLANNING INFORMATION

A. Effectivity

This Service Bulletin affects the model 200SGL147Q-4 starter generators.

B. Reason

To install fan upgrade kit.

C. Description

This Service Bulletin provides detailed instructions on upgrade of starter generator model
200SGL147Q-4 to 200SGL147Q-6.

D. Compliance

This Service bulletin introduces an improvement, and accomplishment is recommended at the next
overhaul.

E. Materials

Table 1: Parts List for Upgrading Model 200SGL147Q-4

Part Number Description Qty


200SGL1107-10 Assy, Fan 1
150SG1093-2 Wave Spring 1
150SG1391 Spring Holder 1
150SG1071 Double Hex Nut 1
200SGL1092-92S ID Plate for 200SGL147Q-6 1
160SG1014-7-2 Swirl Fan Inlet Cover Assembly 1
MS21318-13 Drive Screw 4

Revision: NC SB 200SGL200
19 September, 2018 Page 1 of 7
Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012

F. Approval

This Service Bulletin has been shown to comply with the applicable Federal Aviation
Regulations and FAA approval is not required.

G. Man-Hours Required

No additional time is required for units at overhaul.

H. Weight and Balance.

Weight and balance of starter generator is not affected.

I. Electrical Load Data

Not affected.

J. References

None.

K. Other Publications Affected

None.

3. REMOVAL OF EXISTING STANDARD FAN

Remove existing fan assembly as described in the following steps.

A. Remove fan cover held in place with four radial screws. See Figure 1.

B. Remove double hex nut and spring washers. See Figure 2.

C. Remove existing fan by pulling on the fan hub. See Figure 3.

Revision: NC SB 200SGL200
19 September, 2018 Page 2 of 7
Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012

Radial Screw

,
31
Figure 1: Removal of Radial Screws on Existing Fan Cover

Spring
Washers

Double
Hex Nut

Figure 2: Removal of Radial Fan Screws

Revision: NC SB 200SGL200
19 September, 2018 Page 3 of 7
Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012

Standard Fan

Fan Hub

Figure 3: Removal of Existing Fan

4. INSTALLATION OF NEW SWIRL FAN ASSEMBLY

A. Install 7 Blade Swirl Fan Assembly onto the drive shaft until it meets a hard stop against
the generator. Make sure that the teeth on the spline match the mating spline of the Fan
Insert when installing the assembly. See Figure 4.

B. Place the Wave Spring within the hole provided by the Fan Insert.

C. Install the Spring Holder onto the shaft so that it encloses the Wave Spring.

D. Fasten the Spring Holder to the fan using the Double Hex Nut. Torque the nut to 50 in-lbs
using a calibrated torque wrench with a 3/4” socket. See Figure 5 for an exploded
illustration of steps B-D.

E. Install new Fan Inlet Cover onto the generator and fasten using screws. See Figure 6.

F. Apply a “torque stripe” to the end of the drive shaft to identify that the nut has been
properly torqued. See Figure 7 for an example of how a “torque stripe” should be
represented.

Revision: NC SB 200SGL200
19 September, 2018 Page 4 of 7
Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012

7 Blade Swirl Fan Assembly

Figure 4: Installing 7 Blade Swirl Fan

Spring Washer
R

Spring Holder
O
R F

Double
Hex Nut
O D
LI
VA

Figure 5: Installing the Wave Spring, Spring Holder and Double Hex Nut to the Swirl Fan

Revision: NC SB 200SGL200
19 September, 2018 Page 5 of 7
Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012

Swirl Fan Inlet Cover

Figure 6: Installing Swirl Fan Inlet Cover

Torque Stripe

Figure 7: “Torque Stripe” Applied on the Drive Shaft of a Standard Fan Unit

Revision: NC SB 200SGL200
19 September, 2018 Page 6 of 7
Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012

5. ID PLATE REPLACEMENT INSTRUCTIONS

1. Take note of the orientation and serial number of the existing ID Plate. The new ID Plate shall be
installed in the same position and orientation.

2. Remove the old ID Plate by gently prying on each Drive Screw.

3. Remove all of the original Drive Screws (discard) and remove the old ID Plate.

4. Mark ID plate with original serial number and suffix letter “M2” (e.g S0001M2 for original serial
number S0001).

5. Place the new ID Plate in the same position and orientation and form the ID Plate to the outside
diameter of the starter generator. Press each Drive Screw in as far as possible by hand.

6. Gently tap each Drive Screw until the screw head touches the ID Plate, and the ID Plate is flush
with the surface of the Starter Generator. See Figure 8.

7. Place the old ID Plate in an envelope and return to:


Skurka Aerospace Inc.
4600 Calle Bolero
Camarillo, CA 93012
Attn: Bill Foltz, Quality Manager

Figure 8: Installing the ID Plate

REVISIONS
Version Release Date Comments
NC 10/24/18 Original Issue

Revision: NC SB 200SGL200
19 September, 2018 Page 7 of 7

You might also like