The document outlines a preventive maintenance program for engineering equipment at a hotel. It lists 96 pieces of equipment such as pumps, fans, air conditioners and lifts along with their locations. For each month it indicates scheduled maintenance tasks to be performed on the equipment, such as changing oil, filters, batteries and testing air conditioner sensors. The program aims to prevent equipment issues and keep all engineering systems in good working order through regular inspections and servicing.
The document outlines a preventive maintenance program for engineering equipment at a hotel. It lists 96 pieces of equipment such as pumps, fans, air conditioners and lifts along with their locations. For each month it indicates scheduled maintenance tasks to be performed on the equipment, such as changing oil, filters, batteries and testing air conditioner sensors. The program aims to prevent equipment issues and keep all engineering systems in good working order through regular inspections and servicing.
The document outlines a preventive maintenance program for engineering equipment at a hotel. It lists 96 pieces of equipment such as pumps, fans, air conditioners and lifts along with their locations. For each month it indicates scheduled maintenance tasks to be performed on the equipment, such as changing oil, filters, batteries and testing air conditioner sensors. The program aims to prevent equipment issues and keep all engineering systems in good working order through regular inspections and servicing.
Periode Year : 2015 Januari Februari Maret April Mei Juni Juli Agustus September Oktober Nopember Desember No EQUIPMENT Location 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 1 BOOSTER PUMP 1 Roof Top 2 BOOSTER PUMP 2 Roof Top 3 BOOSTER PUMP 3 Roof Top 4 BOOSTER PUMP 4 Roof Top 5 BOILER PUMP 1 Basement 6 BOILER PUMP 2 Basement 7 TRANSFER PUMP 1 Basement 8 TRANSFER PUMP 2 Basement 9 DEEPWEEL PUMP Ground Floor 10 JOCKEY PUMP Basement 11 ELECT. FIRE PUMP Basement 12 DIESEL PUMP Basement 13 HYDRANT BOX All Floor/Area 14 APAR All Floor/Area 15 WTP PUMP 1 Basement 16 WTP PUMP 2 Basement 17 SUMPIT PUMP 1 Basement 18 SUMPIT PUMP 2 Basement 19 SUMPIT PUMP 3 Basement 20 SUMPIT PUMP 4 Basement 21 SUMPIT PUMP 5 Basement 22 SUMPIT PUMP 6 Basement 23 WATER FAL PUMP Ground Floor 24 BBM PUMP 1 Basement 25 BBM PUMP 2 Basement 26 PREASURE FAN 1 Roof Top 27 PREASURE FAN 2 Roof Top 28 Boiler Fan Basemant 29 Fresh Air Bs Basemant 30 Exhaust Bs Basemant 31 Fresh Air 1 Kitchen 32 Exhaust 1.1 Toilet lobby 33 Exhaust 1. 2 Kitchen 34 Exhaust 2. 1 Toilet 2nd floor 35 Exhaust 2. 2 Pre Fungtion 36 Exhaust 2. 3 Lounge bar 37 Exhaust 3. 1 Male Loker 38 Exhaust 3. 2 Female Loker 39 Exhaust Rest Room 1 Roof Top 40 Exhaust Rest Room 2 Roof Top 41 PANEL MDP Basement 42 PP. BS Basement 43 PP. AC BS Basement 44 PP. LAUNDRY Basement 45 PP. TRANSFER PUMP Basement 46 PP. SUMPIT Basement 47 PP. DEP WELL Basement Januari Februari Maret April Mei Juni Juli Agustus September Oktober Nopember Desember No EQUIPMENT Location 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 48 PP. WTP Basement 49 PP. BBM PUMP Basement 50 PP. HYDRANT Basement 51 PP. KITCHEN 1st floor 52 PP. 1 1st floor 53 PP. AC1 1st floor 54 PP. 2 2nd floor 55 PP. AC-2 2nd floor 56 PP- 2 2nd floor 57 PP. AC 2 3 th floor 58 PP 3 3 th floor 59 PP. AC 3 3 th floor 60 PP. 5 5 th floor 61 PP. 6 6 th floor 62 PP. 7 7 th floor 63 PP. 8 8 th floor 64 PP.9 9 th floor 65 PP.AC 9 9 th floor 66 PP. ROOF TOP Roof Top 67 Room Control Panel 9 th floor 68 TAMBLER 1 Basement 69 TAMBLER 2 Basement 70 TAMBLER 3 Basement 71 MANGLER 1 Basement 72 MANGLER 2 Basement 73 WASHING 1 Basement 74 WASHING 2 Basement 75 WASHING 3 Basement 76 WASHING 4 Basement 77 Walk in Chiller 1 st Floor 78 Walk in Frezeer 1 st Floor 79 Upridge Chiller 1 1 st Floor 80 Upridge Chiller 2 1 st Floor 81 Upridge Chiller 3 1 st Floor 82 Kuali Ring 1 st Floor 83 Food Warmer 1 st Floor 84 Washing Steamer 1 st Floor 85 Fryer 1 st Floor 86 Bio Master Ground Floor 87 Grease trap Basemant 88 Raw Tank 1 st Floor 89 Clean water Tank 1 1 st Floor 90 Clean water Tank 2 1 st Floor 91 Clean water Tank 3 1 st Floor 92 Roof Tank Roof Top 93 Audio Video 1 st Floor 94 Paging System 1 st Floor 95 MCFA Basement 96 CCTV Basement 97 MATV 1 st Floor Januari Februari Maret April Mei Juni Juli Agustus September Oktober Nopember Desember No EQUIPMENT Location 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 98 PABX System 1 st Floor 99 Genset Basemant 100 Boiler 1 Basemant 101 Boiler 2 Basemant 102 GUEST LIFT 1 103 GUEST LIFT 2 104 SERVICE LIFT 105 PRIVATE LIFT
Prepared by, Approved by,
Chief Engineer General Manager
ENGINEERING DEPARTMENT PREVENTIVE MAINTENANCE PROG Periode Year : Januari Februari Maret April Mei Juni Juli Agustus September Oktober Nopember Desember No EQUIPMENT Location 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 AC SPLIT Bs 1 EDR 2 AC SPLIT Bs 2 EDR 3 AC SPLIT Bs 3 HK 4 AC SPLIT Bs 4 HRD 5 AC SPLIT Bs 5 PURCHASING 6 AC SPLIT Bs 6 ENG 7 AC SPLIT Bs 7 PANEL 8 AC SPLIT Bs 8 SECURITY 9 AC SPLIT Bs 9 EAM 10 AC SPLIT 1.1 OPERATOR 11 AC SPLIT 1.2 FOM 12 AC SPLIT 1.3 RUBISH 13 AC SPLIT 1.3 MARKETING
Prepared by, Approved by,
Chief Engineering General Manager
Desember 51 52 53 ENGINEERING DEPARTMENT PROJECT MAINTENANCE PROGRAM Periode Year : MONTH NO JOBS LOATION REMARK Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
1 Perbaikan puvling block lantai parkir area Sekeliling Hotel Done
2 Ganti Oli, filter oli, filter racor, filter air Basement Done 3 Ganti Battery Genset Basement 4 Pembelian alat test air accu 5 Perbaikan sensor pintu guest lift No. 1 Done 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26