You are on page 1of 4

GEP200-4

Designed for the Rental Market


EU Stage II Emissions Compliant

Image may not represent actual model and options


Diesel Generator Set
Exclusively from your Cat® dealer

Output Ratings Prime* Standby*


180.0 kVA 200.0 kVA
380-415V, 50 Hz
144.0 kW 160.0 kW

* KEY FEATURES

RELIABLE PERKINS DIESEL ENGINE INTEGRATED CONTROL PANEL AND CIRCUIT


Perkins engine certified to EU 2007 Stage II BREAKER
emissions standards, delivering industry leading Fully equipped control panel with all
fuel efficiency, load acceptance and product life necessary gauges and protective features
Replaceable air, fuel, and oil filters positioned for Fully rated mainline circuit breaker housed
easy access and serviceability in vibration isolated sheet steel enclosure

MATCHED GENERATOR AND REGULATOR RUNNING TIME


Self-exciting, self-regulating brushless Redesigned fuel tank always delivers eight
generators built for extended, dependable life. hours of performance at 100% of rated
Fully sealed regulator accurately maintains load load in prime applications while meeting
voltage at +/-0.5% from no load to full load the strictest environmental regulations
required today
SUPERIOR SOUND-ATTENUATED ENCLOSURE Environmentally sensitive fuel tank design
Highly corrosion-resistant galvanized steel provides 110% spill containment of all
construction provides a long-lasting exterior engine fluids
finish
Scratch and rust resistant zinc phosphate and ENHANCED SERVICEABILITY
polyester powder-coated paint Oversized hinged or lift-off doors allow for
Single piece main roof incorporating flush- faster and easier maintenance
mounted rain caps with compression seals Single-side access to all regularly serviced
provides protection from water ingress parts
Corner posts and air handling units comprised of Tower control panel with full height hinged
high-grade composite materials door and removable gland plate allows full
Noise absorbent materials and smart design access to cable from both vertical or
help make the generators among the quietest in horizontal locations with eight times outside
the world (typically less than 65 dBA @ diameter bend radius
7meters/95 LWA) Fuel pipe installation through dedicated
Internal exhaust silencer system enhances access holes located on the same side as
generator set safety, aesthetics, and silencer life the remote tank fuel transfer connection
Lockable control panel viewing window and fuel Purpose designed base frame drag points
fill and battery access doors improves safety and an internal single point lift allow for
and security easy handling

RENTAL PACK FLEXIBILITY


Select features enhance usability in rental Common platform design maximizes
applications opportunity for usage in rental or sales
Forklift access, battery disconnect switch, applications
RacorTM fuel water separator, three way fuel
valves, breaker terminal extensions
LEHF0169-00
Factory Installed Standard and Optional Equipment

SYSTEM STANDARD EQUIPMENT

Genset Perkins diesel engine certified to meet EU 2007 Stage II emissions standards
Electronic governor
Replaceable element, dry cartridge type air filters
Heavy duty industrial exhaust silencer
8 hour fuel tank
Replaceable element fuel filter
Spin-on full flow lube oil filters
Power Wizard 1.1 Control panel
Self exciting, self regulating, brushless alternator with automatic voltage regulator and IP23 protection
Robust steel constructed base frame with vibration isolators between base and engine-alternator
12V starting motor and battery charging alternator
High capacity, low maintenance battery, battery rack (base mounted) and heavy duty cables
Radiator and cooling fan with coolant fill (50% antifreeze protection to -36 C)
CE guards for fan, fan drive, and charging alternator
3-Pole molded case circuit breaker
Coolant and lube oil drains piped to edge of baseframe

OPTIONAL FEATURES Sound attenuated enclosure (includes single point lift and exhaust silencer system with anti-rattle bushes)
Recommended for Bunded base tank
Rental Rental Pack (Forklift base feet, Racor fuel/water separator, 3-way fuel valves, Battery isolator switch
Breaker terminal extensions)
Isochronous electronic governor
4-Pole Circuit Breaker
Permanent magnet excitation system and upgraded AVR options
PowerWizard 1.1+ Control Panel (includes auto start capability)
Control Panel Upgrades
Speed adjust potentiometer
Voltage adjust potentiometer
Panel mount audible alarm
Overload shutdown via breaker
Protective devices
Low fuel level alarm and shutdown
Low coolant level shutdown
Fuel level sender and display
Earth fault / leakage

Other OPTIONAL Battery charger


FEATURES Coolant heater
Anti-condensation heater
Control panel upgrades
Lube oil temperature gauge
Volt free contacts
Control panel heater
Remote monitor & control
Programmable annunciator
Manual fuel pump
Lube oil drain pump
Language options
Protective devices
High fuel level alarm
Low coolant temperature alarm
High lube oil temperature shutdown
Toolkit
Test reports and Inspections
CE certification

LEHF0169-00 2
Technical Data
Alternator Diesel Engine
Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Olympian Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Perkins
Model . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL5014F Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1106C-E66TAG4
Winding Pitch - Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2/3 - 6 No of cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 / in-line
No. of wires - poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 - 4 Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 stroke
Excitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shunt Bore – mm (in). . . . . . . . . . . . . . . . . . . . . . . . . . . . 105.0 mm (4.1 in)
Number of bearings. . . . . . . . . . . . . . . . . . . . . . . . Single bearing Stroke – mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . 127.0 mm (5.0 in)
3
Insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class H Displacement – L (cu in) . . . . . . . . . . . . . . . . . . . . . . 6.6 L (402.8 in )
Ingress Protection Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP23 Engine RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
Alignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot shaft Induction . . . . . . . . . . . . . . . . Turbocharged Air to Air Charge Cooled
Overspeed capability . . . . . . . . . . . . . . . . . . . . . . . . . . . 2250 RPM Governor type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic
AVR Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R448 Governing class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISO8528 G2
Voltage regulation (steady state%) . . . . . . . . . . . . . . . . . . . ± 1⁄2% Engine electrical system ……………………… 12V / Negative ground
Wave form NEMA = TIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Battery charger amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Waveform IEC = THF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2% Recommended fuel . . . . . . . . . . . . . . . . . . . . . . . . . . Class A2 Diesel
Total Harmonic Content LL/LN . . . . . . . . . . . . . . . . . . . . . . . 4% Oil Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . API CH4/CI4 15W-40
Radio interference suppression is in line with European Standard
EN61000-6

50Hz 50 Hz 60 Hz 60Hz
Units
PERFORMANCE DATA Prime Standby Prime Standby

Engine Speed RPM 1500 1500 - -


Gross Engine Power kW (hp) 163.7 (220.0) 180.5 (242.0) - -
BMEP kPa (psi) 1985.0 (287.9) 2188.0 (317.4) - -
Regenerative Power kW 8.8 8.8 - -
Fuel System
Fuel consumption *
100% Load L/hr (gal/hr) 39.7 (10.5) 43.5 (11.5) - -
75% Load L/hr (gal/hr) 30.5 (8.1) 33.7 (8.9) - -
50% Load L/hr (gal/hr) 20.7 (5.5) 23.0 (6.1) - -
(*based on diesel fuel with a specific gravity of 0.85 and
conforming to BS2869, Class A2)
Air System
Combustion air flow m /min (cfm)
3
11.3 (399) 11.7 (413) - -
Maximum combustion air intake kPa (in H2O) 8.0 (32.1) 8.0 (32.1) - -
restriction
Cooling System
Ambient Capability °C (°F) 50 50 - -
Radiator cooling air flow m /min (cfm)
3
309.0 (10912) 309.0 (10912) - -
Cooling system capacity L (gal) 27.0 (7.1) 27.0 (7.1) - -
Lubrication System
Total oil capacity L (gal) 16.5 (4.4) 16.5 (4.4) - -
Oil pan L (gal) 15.5 (4.1) 15.5 (4.1) - -
Exhaust System
Exhaust gas flow m3/min (cfm) 19.4 (685) 19.4 (685) - -
Exhaust gas temperature °C (°F) 440 (824) 453 (847) - -
Noise Rating @ 100% Load
(with optional enclosure)*
@ 1meter dB(A) 78.1 78.3 - -
@ 7 meters dB(A) 66.2 66.5 - -
@ 15 meters dB(A) 60.2 60.5 - -
Alternator Data
Frequency Hz 50 50 50 50 60 60 60 60 60
Voltages V 415/240 400/230 380/220 220/127 480/277 380/220 240/120 230/115 440/254
230/115 220/110 240/139 220/110 208/120 220/127
200/115

Motor Starting Capability kVA 414 389 356 457 - - - - -


Short Circuit Capacity ** % 300 300 300 300 - - - - -
Reactances
Xd P.U. 2.515 2.707 2.999 2.237 - - - - -
X’d P.U. 0.123 0.133 0.147 0.110 - - - - -
X’’d P.U. 0.074 0.080 0.088 0.066 - - - - -

LEHF0169-00 3
Weights and Dimensions
Weight with Lube oil
Fuel
Length Width Height and Coolant
Model capacity
mm (in) mm (in) mm (in) kg (lb)
L (US gal)
GEP200-4 with optional sound attenuated
3520 (138.6) 1320 (52.0) 1815 (71.5) 418 (110) 2020 (4453)
enclosure
GEP200-4 with optional sound attenuated
3520 (138.6) 1320 (52.0) 1915 (75.5) 418 (110) 2020 (4453)
enclosure and forklift pockets

Note: General configuration not to be used for installation. Unit shown with optional sound attenuated enclosure
and forklift pockets.

DEFINITIONS AND CONDITIONS


Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power
failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in
ISO 8528-3).

Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased
power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour
in 12 hours.

Standard Reference Conditions


Note: Standard reference conditions 25 C (77 F) air inlet temperature, 100m (328 ft) A.S>L. 30% relative humidity. Fuel
consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869:1998, Class A2.

Quality Standards
BS4999, BS5000, BSEN60034, BSEN61000, IEC60034

Warranty
All equipment carries full manufacturer’s warranty.

Information contained in this publication may be considered confidential. Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.
CAT, CATERPILLAR, their respective logos, OLYMPIAN, “Caterpillar Yellow,” the “Power Edge” trade dress as
well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

www.OlympianPower.com

© 2011 Caterpillar
LEHF0169-00 All rights reserved.
LEHF0169-00 (03-11) 4 Printed in U.S.A.