The document provides procedures for overhauling a motor, including arranging a spare motor with matching specifications, obtaining a shutdown from the concerned department, isolating power and placing a danger board to avoid accidents, disconnecting and removing the old motor, checking the new motor's insulation resistance and winding resistance as well as its star/delta link, checking the coupling alignment, reconnecting and covering properly, and doing a trial run of the new motor. Safety is emphasized as the highest priority by requiring isolation of power sources during the work.
The document provides procedures for overhauling a motor, including arranging a spare motor with matching specifications, obtaining a shutdown from the concerned department, isolating power and placing a danger board to avoid accidents, disconnecting and removing the old motor, checking the new motor's insulation resistance and winding resistance as well as its star/delta link, checking the coupling alignment, reconnecting and covering properly, and doing a trial run of the new motor. Safety is emphasized as the highest priority by requiring isolation of power sources during the work.
The document provides procedures for overhauling a motor, including arranging a spare motor with matching specifications, obtaining a shutdown from the concerned department, isolating power and placing a danger board to avoid accidents, disconnecting and removing the old motor, checking the new motor's insulation resistance and winding resistance as well as its star/delta link, checking the coupling alignment, reconnecting and covering properly, and doing a trial run of the new motor. Safety is emphasized as the highest priority by requiring isolation of power sources during the work.
Following preparation to be done before start doing job for motor change / overhauling BEFORE MOTOR REPLACEMENT SPARE MOTOR TO BE ARRANGE Insure arranged motor Frame, mounting and RPM should be same as installed motor.
Do not start work before
confirm motor data is shoutable for replacement motor SHUTDOWN TO BE TAKEN FROM CONCERN DEPARTMENT
SHUTDOWN IS BASIC PROTOCOL
FOR WORKING ANY ELECTRICAL SYSTEM.
While it's understandable
that an interruption is not ideal for facility operations, safety is of utmost importance ISOLATE THE POWER AND PLACE DANGER BOARD ON FEEDER FOR AVOID ACCIDENT NOTE PHASE SEQUENCE & DISCONNECT ALL CONNECTION DISCONNECT ALL CABLE AND EARTH MOTOR REPLACEMENT CHECK IR AND WR OF MOTOR CHECK STAR / DELTA LINK OF MOTOR CHECK ALIGNMENT OF COUPLING CONNECTION AND COVER TO BE PROVIDE PROPERLY DURING TRIAL OF MOTOR