Image shown may not reflect actual configuration ee xo) ay renee Bore — mm (in) 745 (6.7) ‘Stroke = mm (in) 762 (6.4) Displacement — L (in?) 32.1 (1959) Compression Ratio 15.0:1 Aspiration TA Ful System EUI Governor Type ADEM™ Aa Continuous ernie Cs 1100280) | 1100.80) | 1000800) | arocvany | Cmdr Low Fuel Consumption 7260 (7000) | 1280 7000) | 100 (80) [eatin for Low Ful Consumption Standard Features Cat? Diesel Engine + Designed and optimized for low emissions or low fuel consumption + Reliable and consistent performance proven in thousands of applications worldwide Generator Set Package + Accepts 100% block load in one step and meets the NFPA 110 loading requirements + Conforms to ISO 8528-5 G3 load acceptance requirements. + Reliability is verified through prototype testing, which includes torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing Alternators + Superior motor starting capability minimizes the need for oversizing the generator + Designed to match the performance and output characteristics of Cat diesel engines Cooling System + Cooling systems available to operate in ambient temperatures up to 50°C (12°F) + Tested to ensure proper generator set cooling LeHEI211-04 | EMCP 4 Control Panels + User-friendly interface and navigation + Scalable system to meet a wide range of installation requirements + Expansion modules and site specific programming for specific customer requirements. Warranty + 24 months/1000-hour warranty for standby and mission critical ratings + 12 months/unlimited hour warranty for prime and continuous ratings + Extended service protection is available to provide extended coverage options Worldwide Product Support + Cat dealers have over 1,800 dealer branch stores operating in 200 countries + Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements Financing + Caterpillar offers an array of financial products to help you succeed through financial service excellence + Options include loans, finance lease, operating lease, working capital, and revolving line of credit + Contact your local Cat dealer for availability in your region Page 1 of 6 CAT Optional Equipment Engine Air Cleaner Single element 2 Dual element Heavy duty Muffler 1 Industrial grade (15 dB) Starting 1 Standard batteries 1 Oversized batteries 1 Standard electric starter 1D Dual electric starter 1D Jacket water heater Alternator Output voltage Q400v a 3300v oatsv Temperature Rise (over 40°C ambient) 150°C 2. 125°C/130°C O.405°¢ aoc Winding type Random wound Form wound Excitation Self excited internal excitation (IE) Permanent magnet (PM) Attachments 1 Anti-condensation heater O Stator and bearing temperature monitoring and protection Power Termination Type Bus bar O Circuit breaker 24008 800A, 212008 2 160A 220008 225004 230008 232008 QuL QlEC A3-pole Q4-pole ‘OQ Manually operated Electrically operated Trip Unit atsi — GLsiG ALsIG-P Factory Enclosure A Weather protective Sound attenuated Attachments Cold weather bundle 2G lighting package LAC lighting package A Motorized louvers Fuel Tank A Sub-base 1000 gal (3875 L) 1.2000 gal (7570 L) 1.3600 gal (13627 L) Control System Controller QeMop 4.28 QeMop 4.3 QEMcp 4.4 Attachments Local annunciator module Remote annunciator module Expansion 1/0 module Remote monitoring software Charging U1 Battery charger — 108, Vibration Isolators Rubber Spring Seismic rated Cat Connect Connectivity DEthemet 2 Cellular a Satelite Extended Service Options Terms 22 year (prime) 23 year 25 year 2110 year Coverage a Silver Gold Platinum Platinum Plus Ancillary Equipment Automatic transfer switch (ATs) Q Uninterruptible power supply (UPS) Paralleling switchgear O Paralleling controls Certifications UIBC seismic certification LEU Declaration of Conformity Eurasian Conformity (EAC) Note: Some options may not be available on al models. Certifications may not be available with al! mode! configurations Consul factory for availabilty. LeHe1211-04 Page 2 of 8 C32 Diesel Generator Sets x - Electric Power Package Performance 41250 KVA Low Fuel Consumption | Pa ee Nae “maiNn levels ae corrected to §% O> Contact your local Cat dealer for futher information LeHe1211-04 Page 3 ol 8 C32 Diesel Generator Sets x - Electric Power Package Performance 1100 kVA Low Fuel Consumption ‘Gon set power rating with fan 280 kW 80 ekW 200 ek 725 ekW ‘Gen set power rating with fan @ 0.8 power factor | __1100KVA 1100 kVA 1000 KA, S10 KA Fusing strategy Low Fuel Low Fuel Low Fuel Low Fuel Performance number ‘Moest-02 | _emosa7-07 | _pMass2.05 | _DM99s3-071 oko) 100% load with fan — Ur (gal) 2254 (598) | 2264 (598) | 2067 (548) | 1895 (50.1) 75% toad with fan — Lie (ale) 703 (450) [703 so) | 1555 (41a) [1428 G77) 150% load with fan — Uhr (gan) vi74 (310) | 1974 (4.0) | 1088 (287) | 1004 (265) 25% load with fan — Line (gale) ea (183) | 694 (103) | 52 (17.2) | 608 (16.1) Cito Radiator air fow resticton (system) —KPa (n. water] 0.12 (048) | 0.12 (0.48) | 0.12 (048) | 0.12 (048) ne | Exhaust system backpressure (maximum allowable) oe 67 ero) | 67 ero | 67 ero) | 67 ero) Heat rejection to jacket water = KW (Btu) sia ister] ste (r8%67)] 300 (17054) | 261__(15996), Heat rejection to exhaust (otal) — KW (Btu) 18 (aeste)| 818 ae5t8)| 757 __(4s047) | 698 9684) Heat rejection to aercooler— KW (umn) set (ozeay[ ei (so2es)[ 140 (eet) | 125 (7788) Heat ejection to atmosphere from engine — ee 120 797) | 120 (6797) | 108 6150) | 102 (6819) Heat rejection For alemator — KW (Btufmin 7 4 ares) | 1976) | 43 (aaa) | 38 (2163) NOx mg/Nm? (g/hp-h)_ 2966.9 (5.84) | 2966.9 (5.84) | 2967.7 (5.84) | 2914.2 (5.76) “img/Ni lvls are corocted to 5% 0. Contact your local Cat dealer for farther information LeHEI211-04 Page 4 of 6 C32 Diesel Generator Sets x - Electric Power Package Performance 41100 kVA Low Emissions ‘Gon set power rating with fan 280 kW 80 ekW 200 ek 725 ekW ‘Gen set power rating with fan @ 0.8 power factor 100 KA, 1100 kVA 1000 KYA, S10 KA Fusing strategy Low Emissions | Low Emissions | Low Emissions | Low Emissions Performance number ‘Mo04s-0¢ | ewoeae-oo | _pMoa46-o4 | _Dwgoa7-03 oko) 100% load with fan — Ur (gal) 243.2 (642) | 2432 (642) | 2242 (692) | 2030 (535) 75% toad with fan — Lie (ale) sea (48.6) | 1084 406) | s681 (444) [1549 (409) 150% load with fan — Uhr (gan) 7260 (933) | 1260 Ga.) | 1182 _@o4) | 1061 (28.0) 25% load with fan — Line (gale) vos (87) | 709 (187) | 59 (ira) | 615 (162) Cito Radiator air fow resticton (system) —KPa (n. water] 0.12 (048) | 0.12 (0.48) | 0.12 (048) | 0.12 (048) ne ee Exhaust system backpressure (maximum allowable) oe 67 ero) | 67 ero | 67 ero) | 67 ero) Heat rejection to jacket water = KW (Btu) si2_ 7723) 312 _(r7723)] 288 (16392)| 266 (18109) Heat rejection to exhaust (otal) — KW (Btu) 951__(S4087)| 95% 4087)[_ 81 (S0080) | 80% (45572) Heat rejection to aercooler— KW (umn) 253__(14386)| 259 (14086)| 225 _(T2680)| 179 (70754) Heat ejection to atmosphere from engine — 7 , 7 toca 107 6077) | 107 (eo77) | 107 (6081) | 104 (5013) Heat rejection For alemator — KW (Btufmin 7 4 ares) | 1976) | 43 (aaa) | 38 (2163) “img/N levels are corected to 5% 0. Contact your focal Cat dealer for further information LeHEI211-04 Page 5 of 6 Weights and Dimensions Mission Critical | Prime | Continuous ee een pv) EVN a NM) mrp || co eS 1100 (880) | 1100 (880) | 1000 (800)| 910 (728) | 4165 (164.0)| 1684 (66.3) | 2162 (85.1) | 6668 (14,700) 1260 (1000){ 1250 (1000) [1100 (@80)| [4350 (171.3)| 1684 (66.3) [2162 (86.1) [6985 (15,400) Note: For reference only. De not use for instalation design. Contact your loca Cat dealer fr precise weights and dimensions Ratings Definitions Standby Applicable Codes and Standards ‘Output available with varying load for the duration of the interruption ofthe normal source power. Average power output is 70% of the standay power rating. Typical ‘operation is 200 hours per year, with maximum expected sage of 500 hours per year. Mission Critical ‘Output available with varying load for the duration of the interruption ofthe normal source power. Average power output is 85% of the mission ertical power rating Typical peak demand up to 100% of rated power for Lp to 5% of the operating time. Typical operation is 200 hours per year, with maximum expected usage of '500 hours per year. Prime (Output available with varying load for an unlimited time. ‘Average power output is 70% of the prime power rating Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a ‘maximum of 1 hour in 12, Overload operation cannot exceed 25 hours per year. Continuous (Output available with non-varying load for an unlimited time, Average power output is 70-100% of the Continuous power rating. Typical peak demand is 100% of continuous rated kW for 100% of the operating hours. 32 PGDG, 632 PGB! LEHE1211-0¢ (1719) ‘AS1359, CSA C22.2 No100-04, UL142, UL489, UL8S9, UL2200, NFPA37, NFPA70, NEPASS, NFPA110, IBC, 1EC60034-1, 1803045, 1S08528, NEMA MG'.22, NEMA MG1'33, 2014/35/EU, 2008/42/EC, 2014/30/EU, Note: Codes may not be available in all model configurations. Please consult your local Cat dealer for availabilty. Data Center Applications Tier lllTier IV compliant per Uptime Institute requirements, ANSV/TIA-942 compliant for Rated-4 through Rated-4 data centers. Fuel Rates Fuel rates are based on fuel oll of 35° API [16°C (60°F)]

You might also like