You are on page 1of 4

PAGE 45

Sample of manual computation for initial sizes of slab

Slab Name: S6

S = 6000 mm

L = 6000 mm

Type: Two-Way Slab

Minimum Thickness:

t = 2(S+L)/180

= 2(6000 + 6000)/180

Minimum Thickness = 133.33

Say: 150 mm
PAGE 48

Beam Name: B9 H min = L/16 = 750 mm


Support Condition: Simply supported Bmin = 0.3Hmin = 225 mm
L = 12000 mm Hmin = USE 750 mm; Bmin = USE 250 mm
PAGE 60

Sample Calculation:
C5 – Ground Floor
F’c = 27.6
Fy = 414
Tributary Area =64 m2
DL= 5.027
LL = 4.8
DL due to self-weight of beam = 136.88
Modifier = 3
Pu Upper = 6928.736 kN
Pu = (1.2DL +1.6LL) *(A) +1.2(DLbeam) + Pu upper = 7970.56 kN
Ag = Pfactored/ *0.80*[0.85*f'c*(Ag-Ast)+fy*Ast Ag = 479318.8224 mm2
h = √Ag*modifier; h = 1199.148226 mm
USE 1200 mm
Page 69

Steel Design

Sample Calculations:
C1 – Roofline
Properties:
Steel Shape: W30X235 LFRD = 7970.56
Area = 69.3 ASD = 5925.333333
K=1 Rx = 13
L = 4000mm = 157.48 in Ry = 3.51
Bf/2tf = 5.02

Slenderness ratio = kl/r


= 12.11387038< 200; safe for buckling
Limiting width ratio = 0.56√ (29000/36)
= 5.02<15.89; non slender
Slenderness ratio Fcr = 32.38019673
44.8661866 Pn = 9981.57, Pu = 0.8Pn = 8983.42> 7970.56 ;
ADEQUATE
Fe = π^2(29000)/ 44.87 Fe = 142.186848 Pa = Pn/1.67 = 5976.99> 5925.33; ADEQUATE