Stream No.

1 2 3 4 5 6

Scrubbing Spray

Condensate Pots
Two Phase from

Scrubbing Line
Scrubbing Line
Description

Interface to HP

Water Supply

HP Scrubber
HP Steam to

Condensate
HP Steam
HP Steam

HP Steam
Separator
Pipe True Length (m) 49.0 7.0 150.0 160.0 N/A N/A
Nominal Pipe Diameter (mm) 1050.0 1200.0 80.0 1200.0 750.0 100.0
Flow (t/h) Steam 472.5 474.8 - 472.8 - -
Liq. Water 1387.7 0.7 9.7 12.4 7.2 5.2
Impurities 3.8 0.0 - 0.0 0.0 0.0
NCG 11.1 11.1 - 11.1 - -
Total 1875.0 486.6 9.7 496.3 7.2 5.2
Upstream Pressure (bara) 12.0 11.6 TBA 11.6 N/A 11.5
Downstream Pressure (bara) 11.8 11.6 TBA 11.6 N/A 11.4
Temperature (°C) 187.2 186.1 37.6 185.9 185.9 185.5
Superheat (ºC) N/A 0.0 N/A 0.0 N/A 0.0
Upstream Enthalpy (kJ/kg) 1300.0 2779.7 157.5 2731.2 789.5 2758.8
Downstream Enthalpy (kJ/kg) 1299.9 2779.7 157.5 2730.4 N/A 2758.6
Average Steam Quality 0.25 1.00 0.00 0.97 0.00 0.99
Superficial Steam Velocity (m/s) 25.9 20.8 - 20.8 N/A -
Average Fluid Velocity (m/s) 26.4 20.8 0.9 20.8 N/A 0.3
7 8 9 10 11 12 13 14 15 16

Separator Control

Scrubbing Spray

Condensate Pots
Turbine Strainer

Turbine Strainer

LP Steam to LP
HP Brine to LP

Scrubbing Line

Scrubbing Line
Ejector Steam

Water Supply

LP Demister
HP Steam to

HP Steam to

HP Steam to
Power Plant

Condensate
Bifurcation

LP Steam

LP Steam

LP Steam
Valve
1

2
90.0 10.0 4.0 24.0 55.0 12.0 150.0 93.0 N/A N/A
1200.0 250.0 750.0 750.0 750.0 1200.0 80.0 1200.0 750.0 100.0
472.8 22.2 225.3 225.3 - 176.8 - 176.3 - -
0.0 0.0 0.0 0.0 1384.7 0.5 3.5 4.6 2.9 1.7
0.0 0.0 0.0 0.0 0.0 0.0 0.0 - 0.0 0.0
11.1 0.5 5.3 5.3 - - - - - -
483.9 22.7 230.6 230.6 1384.7 177.3 3.5 180.9 2.9 1.7
11.4 11.3 11.3 11.3 11.6 2.1 TBA 2.0 N/A 2.0
11.3 11.3 11.3 11.3 11.7 2.0 TBA 2.0 N/A 1.9
185.0 184.8 184.8 184.8 186.5 120.9 37.6 120.6 120.6 119.6
0.0 0.0 0.0 0.0 0.0 0.0 0.0 N/A 0.0 0.0
2780.3 2779.8 2779.8 2779.8 791.8 2700.9 157.5 2651.1 506.5 2685.3
2780.3 2779.8 2779.4 2779.8 2779.6 2700.9 2700.8 157.5 2650.4 2685.3
1.00 1.00 1.00 1.00 0.00 1.00 0.00 0.97 0.00 0.99
21.2 22.9 26.2 26.2 - 38.7 - 38.9 N/A -
21.2 22.9 26.2 26.2 1.0 38.7 0.3 38.9 N/A -
17 18 19 20 21

Pumps Discharge
Turbine Strainer
Turbine Strainer
LP Steam to

LP Steam to

LP Steam to
Power Plant

LP Brine to
Reinjection

Reinjection
Bifurcation

LP Brine
Pumps
1

2
76.0 4.0 20.0 73.5 TBA
1200.0 900.0 900.0 600.0 600.0
176.3 88.1 88.1 - -
0.0 0.0 0.0 1207.3 1207.3
0.0 0.0 0.0 0.0 0.0
- - - - -
176.3 88.1 88.1 1207.3 1207.3
1.9 1.8 1.8 2.1 TBA
1.8 1.8 1.8 2.5 11.0
119.0 118.5 118.5 120.9 120.9
N/A 0.6 1.2 1.4 1.4
2705.3 2704.7 2704.7 511.3 511.3
N/A 2705.3 2704.7 2704.6 2704.4
1.00 1.00 1.00 0.00 0.00
42.3 38.4 38.4 - TBA
42.3 38.4 38.4 1.4 TBA