You are on page 1of 6

IN MALAYSIA | 2

TEM .16
SYS MW
P
M
|1
U
TP

08
HEA

000
L
LARGEST

RT
GU

SO
INE

RE
RD

W
SS

OR OL

EXTRACTOR ECO
LD W
REC ST
ORD HOTEL : FIR

RENEWABLE HEATING / HEAT PUMP

OPTIMIZE ENERGY FROM SURROUNDING HEAT


HEAT RECOVERY WATER SOURCE
KEY FEATURES

Renewable Heat Recovery Solution


Recover heat from Return Chilled Water or Cooling Tower Water to Heat Pump
for hot water solution.
Non-ozone depleting refrigerant is used for greater performance while conserving
the environment.

Prolong Compressor Lifespan


Provides a linear power slope for smooth acceleration which reduces in-rush current
and excessive wear on mechanical driven components.

CHILLED WATER HEAT PUMP


TECHNICAL SPECIFICATION
ECO 30kW ECO 45kW ECO 60kW ECO 90kW ECO 120kW
DESCRIPTION cWATER cWATER cWATER cWATER cWATER
Type Water to Water
Refrigerant R134A
Water Piping Type Copper
Souce Water In (ºC) 9 ~ 13
Source Water Out (ºC) 6 ~ 10
Primary / Secondary Circulation Pump Optional
Evaporator Type Brazed Plate Heat Exchanger
Max. Water Pressure Drop (Evaporator) 1 Bar
Condenser Type Brazed Plate Heat Exchanger
Max. Water Pressure Drop (Condensor) 1 Bar
Power Supply AC 415V / 50Hz / 3 Phase
Max. Hot Water Temperature (ºC) 63
Average Heating COP 3.3 3.3 3.3 3.3 3.3
Average Cooling COP 2.5 2.4 2.5 2.4 2.5
Average Total COP 5.8 5.7 5.8 5.7 5.8
Average Heating Capacity (kW) 30.0 45.0 60.0 90.0 120.0
Average Cooling Capacity (kW) 23.0 33.0 46.0 66.0 92.0
Average Power Consumption (kW) 9.1 13.7 18.2 27.3 36.4
Max. Operating Current Consumption (A) 35.0 50.0 70.0 100.0 140.0
No. of Circuits 1 1 2 2 4
Hot Water Piping Connection 1 ½” 1 ½” 2” 2” 2 ½”
Source Water Piping Connection 1 ½” 2” 2” 2 ½” 2 ½”
Hot Water Flow Rate (m3/hr) 5.5 7.6 11.0 15.2 22.0
Source Water Flow Rate (m3/hr) 6.5 9.5 13.1 19.0 26.1
Dimension (mm) L 1550 1600 1700 2100 2100
W 700 800 800 900 900
H 1200 1200 1200 1300 1500
Weight (kg) 360 470 650 800 1100
Remarks : Rated at 10ºC source water. Average heating capacityn and COP rated at water heated from 30ºC - 60ºC.
Space Saving Through Stackable Design.
Versatile solution where it can be stacked vertically to accommodate
limited available space.

Suitable for hotel, hospital or any heating application with heating temperature
up to 63ºC.

Optional Intrix SMART Control System


Switch on and off multiple heat pump control, peak tariff and off-peak tariff optimisation,
energy monitoring system, data logging and ready for Building Management System
interfacing.

COOLING TOWER WATER HEAT PUMP


TECHNICAL SPECIFICATION
ECO 30kW ECO 45kW ECO 60kW ECO 90kW ECO 120kW
DESCRIPTION ctWATER ctWATER ctWATER ctWATER ctWATER
Type Water to Water
Refrigerant R134A
Water Piping Type Copper
Max. Souce Water In (ºC) 30
Source Water Out (ºC) 20
Primary / Secondary Circulation Pump Optional
Evaporator Type Shell and Tube Heat Exchanger
Max. Water Pressure Drop (Evaporator) 1 Bar
Condenser Type Brazed Plate Heat Exchanger
Max. Water Pressure Drop (Condensor) 1 Bar
Power Supply AC 415V / 50Hz / 3 Phase
Max. Hot Water Temperature (ºC) 63
Average Heating COP 4.9 4.9 4.9 4.9 4.9
Average Cooling COP 4.1 4.0 4.1 4.0 4.1
Average Total COP 9.0 8.9 9.0 8.9 9.0
Average Heating Capacity (kW) 30.0 45.0 60.0 90.0 120.0
Average Cooling Capacity (kW) 25.0 37.0 50.0 74.0 100.0
Average Power Consumption (kW) 6.12 9.18 12.2 18.3 24.5
Max. Operating Current Consumption (A) 30.0 35.0 60.0 70.0 120.0
No. of Circuits 1 1 2 2 4
Hot Water Piping Connection 2” 2” 2” 2” 2 ½”
Source Water Piping Connection 2” 2” 2” 2” 2 ½”
Hot Water Flow Rate (m3/hr) 5.5 8.08 11.1 16.2 23.0
Source Water Flow Rate (m3/hr) 4.54 6.71 9.10 13.5 20.0
Dimension (mm) L 1600 1600 1650 1900 1750
W 800 800 900 1000 1400
H 1200 1200 1300 1300 1300
Weight (kg) 300 400 500 650 1000
Remarks : Rated at 26ºC source water. Average heating capacity and COP rated water heated from 30ºC - 60ºC.
HEAT RECOVERY AIR SOURCE
KEY FEATURES
Meticulous, Space Saving and Weatherproof Design to Optimise Heat Transfer Process
Designed meticulously for a minimum space with L or V Shaped Evaporating Coil.
A pre-coated, anti-rust heat exchanger optimizing heat transfer process while prolong
product lifespan.
Prolong Compressor Lifespan
Provides a linear power slope for smooth acceleration which reduces in rush current and
excessive wear on mechanically driven components.
Unique Drain Pan Design for a Safe Operation Area
Designed to direct and discharge condensation water.
Building Management System (BMS) ready to comply with overall building’s monitoring system.
Advance Dual Independant System for a efficienct and consistent performance.
Utilises Environment Friendly Refrigerant - R410A.
Designed and Optimised to best suit Tropical Country weather application.

AIR SOURCE HEAT PUMP


TECHNICAL SPECIFICATION

EXTRACTOR EXTRACTOR EXTRACTOR


DESCRIPTION ECO 32 AIR ECO 46 AIR ECO 70 AIR
Type Air to Water
Refrigerant R410A
Evaporator Type Aluminium Fin Copper Tube with Seaside Coating
Condenser Type Brazed Plate Heat Exchanger
Primary Circulation Pump Optional
Max. Discharge Water Temperature (ºC) 60
Mild Steel with Powdered Coating
Casing Material & Finishing [Optional Upgrade to Stainless Steel]
Power Supply AC 380V - 420V / 50Hz / 3 Phase
Average Heating COP 3.5 3.5 3.5
Average Cooling COP 2.3 2.25 2.4
Average Total COP 5.85 5.75 5.88
Average Heating Capacity (kW) 29.0 42.0 67.0
Average Cooling Capacity (kW) 19.0 27.0 46.0
Average Power Consumption (kW) 8.2 12.0 19.2
Max. Operating Current Consumption (A) 19.0 27.0 46.0
No. of Circuits 2 2 2
Hot Water Piping Connection 1 ¼” 1 ¼” 2” (PN16 Flanges)
Condense Piping Connection ½” ½” ½”
Hot Water Flow Rate (m3/hr) 5.0 7.0 12.0
Max. Water Pressure Drop (Bar) 1.0 1.0 1.0
Dimension (mm) L 1550 1550 2100
W 760 760 1200
H 1200 1350 2100
Weight (kg) 200 310 500
Remarks : Rated at 32ºC ambient air. Average heating capacity and COP rated at water heated from 25ºC - 50ºC.
Customise Heat Pump is available upon request.
Visual shown here may differ from actual model(s). Technical Specifications and Features may change without prior notice.
TOUGHTANK
THERMAL ENERGY STORAGE/CALORIFIER

BEYOND TOUGH

3
PRODUCT FEATURES
1 Superior Heat Retention 2 Enhanced Joining Point 3 Quality Material
Utilize light and solid Polyurethane foam Pickling and passivation treatment to Imported superior grade stainless steel from Japan,
insulation with stainless steel cladding to restore corrossion resistance capability Korea and Spain with greater durability and
maximize heat retention. after welding process. high corossion resistance.
4 Excellent Thermal Stratification. 5 Standard Accessories
Engineered with state-of-art diffuser, evenly disseminates incoming cold water to maintain • Air vent valve, ( n+1 ) Anti-Vacuum Valve,
an effective hot water volume up to 90%. Pressure Relief Valve, Pressure Gauge and
Temperature Gauge.
Hot Water 6 Optional Accessories
• Temperature and Pressure Relief Valve.
• Double Action Thermostat.
Mixed Water • Heating Element.
Specification : ≤ 4000L, 1 unit of 15kW
≥ 5000L, 2 units of 15kW
GOOD STRATIFICATION POOR STRATIFICATION 7 Certification
What is Thermal Stratification? Department of
A physical process that hot fluids will naturally position itself higher than the cold fluids. A greater Occupational Safety
and Health.
thermal stratification calorifier will minimise the energy needed for second recirculation.

TECHNICAL SPECIFICATION
Vertical Series (VRT)
MODEL VRT1500 VRT2000 VRT2500 VRT3000 VRT4000 VRT5000 VRT6000 VRT7000 VRT8000
Nominal Capacity (L) 1500 2000 2500 3000 4000 5000 6000 7000 8000
Dimension Diameter (mm) 1159 1296 1416 1528 1628 1698 1940 2040 2262
Height (mm) 2616 2650 2691 2747 2925 3430 3498 3464 3427
Empty Tank Weight (kg) 500 600 760 800 830 850 1200 1400 1700
Full Water Tank Weight (kg) 2000 2600 3260 3800 4830 5850 7726 8400 9700
Water Outlet 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½"
Water Inlet 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½"
Secondary Return 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½"
Operating Pressure 6 Bar
Tank Material SS304L / SS316L

Horizontal Series (HRT)


MODEL HRT4000 HRT5000 HRT6000 HRT7000 HRT8000 HRT9000
Nominal Capacity (L) 4000 5000 6000 7000 8000 9000
Dimension Diameter (mm) 1550 1698 1990 2312 2366 2392
Height (mm) 1945 2093 2381 2690 2806 2858
Length (mm) 3265 3266 3242 3279 3587 3587
Empty Tank Weight (kg) 960 1155 1487 1813 1978 2150
Full Water Tank Weight (kg) 4960 6155 6490 8820 9000 11150
Water Outlet 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½"
Water Inlet 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½"
Secondary Return 2 ½" 2 ½" 2 ½" 2 ½" 2 ½" 2 ½"
Operating Pressure 6 Bar
Tank Material SS304L / SS316L
Customise Heat Pump is available upon request.
Visual shown here may differ from actual model(s). Technical specifications and features may change without prior notice.

OTHER
PRODUCTS
FROM INTRIX
Thermostatic Multipoint Residential / Light 100% Heat Recovery High Temperature Industrial Humiidty Control
Instantaneous Water Heater Commercial Heat Pump Chiller Heat Pump (90ºC) Heat Pump Dryer

INTRIX is a passionate and Innovative engineering AUTHORISED DISTRIBUTOR


company expertise in Thermal Physics to provide heating
and cooling solutions, RH Control, and Drying
Technology to fulfil residential and commercial market
demands while providing the best customer experience.

INTRIX RENEWABLE SDN. BHD.


Unit 2, Teknologi Kubik,
No. 6, Jalan Teknologi 3/4,
Taman Sains Selangor 1,
47810 Petaling Jaya, Selangor Darul Ehsan. Version date 1/11/16
Tel +603-7496 6213 Fax +603-6151 5298