You are on page 1of 1

R32 Heat Pump Air to Water

TGTP-8HMDA1

Outdoor Unit TGTP-8HMDA1 Hydronic Modul TGHM-8HMDA1


Power supply V/Ph/Hz 220~240/1/50 Power supply V/Ph/Hz 220~240/1/50
Performance data Space heating ºC 25~60
Leaving water
Capacity kW 5
8 Space cooling ºC 5~25
temperature
Rated Heating *1 Power input kW 1,13 Domestic hot water ºC 40~60
COP kW/kW 4,4 Max. power input kW 3,6
Capacity kW 4,5 Max. current input A 17
Rated Cooling *2 Power input kW 1,66 Sound power level dB(A) 45
EER kW/kW 2,7 Dimension (W×H×D) mm 490*910*340
Capacity kW 5 Packing (W×H×D) mm 620*1105*425
Heating *3 Power input kW 1,56 Net/gross weight kg 47/55
COP kW/kW 3,2 Piping Outlet mm DN32
Capacity kW 4,2 connection Dia. Inlet mm DN32
Cooling *4 Power input kW 1,1 Safty valve kPa 600
EER kW/kW 3,8 Drainage pipe Dia. mm DN20
Seasonal space heating water outlet @ 35ºC A++ Volume L 2
energy eff. Class Expansion tank Max. water pressure kPa 800
(average climate general) water outlet @ 55ºC A++ Water circuit
Pre pressure kPa 150
Max. power input kW 2,86
Water side heat Type Plate type
Max. current input A 13
exchanger Volume L 0,658
Sound power level dB(A) 64
Brand wilo
Physical data
Water pump Model Para 25/9
Dimension (W×H×D) mm 935×702×382
Pump head m 9
Packing (W×H×D) mm 975×770×435
Liquid side Dia. mm Ø9.52
Net/gross weight kg 47/51 Refrigerant circuit
Gas side Dia. mm Ø15.88
Brand Mitsubishi
Power supply V/Ph/Hz 230V/1Ph/50Hz
Type Rotary DC Inverter
Capacity kW 3kW
Model SVB140FVCMC Back-up E-heater
Compressor Max. power input kW 3kW
Poles 6
Max. current input A 13.6A
Speed rps 10~130
Piping connections
Oil FW68S/350mL
Type Flaring
Number of fans 1 Liquid pipe
Outdoor fan Dia.(OD) mm Ø 9.52
Air flow m3/h 3200
Type Flaring
Gas pipe
Dia.(OD) mm Ø 15.88
Max. piping length m 20
Outdoor unit upside m 10
Max. height difference
Oudoor unit downside m 10
Type R32
Quantity kg 1,1
Refrigerant Throttle type EXV
(Total pipe length -
Additional charge g
5) m *30g/m
Cooling ºC -5~46ºC
1. T
 he rated heating conditions: water flow 0.172m^3/(h·kW), ambient temperature 7°C DB, water Ambient temperature
inlet/outlet temperature 30/35°C. Heating ºC -28~43ºC
range
2. The rated cooling conditions: water flow 0.172m^3/(h·kW), ambient temperature 35°C DB, water Sanitary hot water ºC -28~43ºC
inlet/outlet temperature 12/7°C.
3. Heating condition: water flow 0.172m^3/(h·kW), ambient tempeature 7ºC, water inlet/outlet Cooling ºC 5~25ºC
temperature 40/45ºC. Water temperature range Heating ºC 25~60ºC
4. Cooling condition: water flow 0.172m^3/(h·kW), ambient tempeature 35ºC, water inlet/outlet
Sanitary hot water ºC 40~60ºC
temperature 23/18ºC.