DAIWHA Infusion Pump


medifusion@mpMQPPP
SPECIFICATION
Infusion Pump
p’„•ƒ”@n…
m„…Œ
Volumetric Infusion Pump
MEDIFUSION MP-1000
MEDIFUSION MP-1000
p•‰Ž‡@s™“”… PERISTALTIC SEMI-TRANSIT FINGER High Performance & Easy Operation
fŒ—@r”…@rŽ‡… 0.1 to 99.9ml/h (in 0.1ml/h increments)
100ml/h to 999ml/h (in 1m/h increments)
aƒƒ•’ƒ™ 5 % with assigned IV set
vŒ•…@d…Œ‰–…’…„ 0.1 to 9,999 ml
p•’‡…@fŒ—@r”… 700 ml/h (or selectable)
vŒ•…@l‰‰”@rŽ‡… 0.1 to 9,999 ml
aŒ’“@F@iŽ„‰ƒ”’“ Air in line
Infusion complete
Occlusion (Up/Down)
Empty container
Low battery
Door open
Other device malfunctions
f•Žƒ”‰Ž Keep-Vein -Open
Drop sensor (Controls drip rate of IV sets and detect
irregularities in drop count)
Tubing Clamp Mechanism
Broad Range of Delivery rate settings
Volume Memorize Function
Selectable One Shot Purge
Easy replacement of Battery & convenent Battery indicator
Free drop protection Finger
User Selectable setup (IV set, sound, occlusion, etc)
p—…’@r…‘•‰’……Ž” AC 100 to 240V, 50/60hz, External 12V DC
p—…’@cŽ“•”‰Ž Less than 30VA
cŒ““‰†‰ƒ”‰Ž Class I, Type BF, IPX 1
b””…’™@s•’ƒ… Rechargeable Nickel-Metal Hybride Battery can run
the pump continuously for about 3 hours at an operating
rate of 25ml/h
cŽ“”’•ƒ”‰Ž Drip Proof
aƒƒ…““’‰…“ AC Power, Drop Sensor, IV Sets, Operation Guide
d‰…Ž“‰ŽHI (D)166 X (W)258 X (H)125
w…‰‡ˆ” Approx 3.2 Kg

Distributor:

Head Quarter ;
DAIWHA Bldg. 733-18, Yeoksam-Dong, Kangnam-Ku, Seoul, Korea
Phone : 82-2-558-1711〜6 / Fax : 82-2-554-0317
Home Page : http://www.daiwha.com / E-mail : daiwha@daiwha.com
Factory ;
177, Youngchun Ri, Dongtan Myun, Hwasung Si, Kyungki Do, Korea
Phone: 82-31-376-9383~6 / Fax: 82-31-376-9387

Printed in Korea 2003


High Performance & infusion@pump www.daiwha.com

Easy Operation medifusion@mpMQPPP


●Drop sensor

Broad Range of Improved Drop Sensor Safety Features


Flow Rate Settings
The drop sensor controls flow rate of IV - A keep vein open (KVO) system that
The flow rate can be set up to a maximum
fluid, and detects irregularities in drop prevents the blood access from closing
● Infused volume indicator of 999ml/h, and can be adjusted in 0.1ml/h
count. once the programmed infusion volume has
increments up to 99.9ml/h.
been delivered.

● Total volume indicator ● Alarm indicator


(Air, Occlusion, Door open,
Low battery, Infusion complete)

● Volume display

● Up occlusion sensor

● Interworking part lever

● Flow rate display


Compatible with Most IV Sets Convenient Battery Indicator - A tube-clamping mechanism that
● Purge indicator
automatically stops infusion when the door
● Stop indicator is inadvertently opened, and accidental
● Interworking part The MP-1000 has a pre-programmed data
A 3-Level indicator displays the charging power cutoff prevention that allows the
for all kinds of standard IV sets. The
● Infusion indicator status and remaining capacity of the pump to continue running even if the
operator can make it possible to use the
in progress internal battery, so that the operator ON/OFF key is mistakenly pressed during
● Mode key pump with any standard IV sets without
knows when to get spare batteries or infusion.
special trying and efforts.
switch over to AC power. - The MP-1000 has a drip-proof
● Purge key construction that protects it from infiltration
● Start key by water or IV solution, and it complies
● Selection key Memory Function with electromagnetic compatibility (EMC)
● Stop key
Battery Replacement is Easy standards.
When the power is turned off, the unit
The batteries can be easily replaced
stores and retains the most recent
● Flow rate setting keys ● Down occlusion sensor simply by opening the battery cover at the
flow rate, total volume.
bottom of the unit. Application
● ON/OFF key
- Continuous low flow rate infusion of fluid
● Air sensor Variable Alarm Functions drug and transfusion in ICU or CCU
Clears EMC Standards - Continuous infusion of anesthetic, anti-
● Power source indicator - Air in line cancer agent and nutrient to immature
- Occlusion The pump conforms to international infant or newborn
- Door open standards for electromagnetic
- Low battery compatibility (EMC), which require that
- Infusion complete devices not be affected by
- Empty container electromagnetic fields from external
- Other device malfunction sources and not emit electromagnetic
● Battery indicator
waves sufficient to affect the operation of
other electronic devices.