You are on page 1of 2

Drawing to be rejected due to the following reason:

1. Direction of grating does not match with Designed direction at some location.
2. Support grating length is less than 32mm , refer to comment 3.
3. Grating split does not locate on supporting beam see comment 2.
4.Supplimentary grating support location does not match with standard drawing see comment 4.
5. grating to be split into two panels at center of opening with diameter more than 200mm.
6.Opening size around post is not correct , see comment 6.
7. split grating location is recommended at center of beam to make all grating panel uniform.
COOEC is to check all comments and study grating layout in accordance with standard drawing then
reflect it into grating drawing.

Opening for gusset plate


Please split grating into two panel for
Please revise split grating panel as red opening more than 200mm general
Missing opening for PPL
line. comment)

Direction of grating G40 do not comply


with design drawing. COOEC is to
check and update.

Comment 3: Min overlap between


grating and its support is 32mm as per
standard drawing L001-00000-
CS-2408-1005. Current overlap is less
than 32mm. COOEC is to check and
update as general comment.
Opening location to be moved
to red line location.

20

Comment 5:
This opening is more than 200, so Comment 6:
Please correct opening location as red
please slit grating into two panel along Missing grating support at this location Opening size is 240*240 to keep the
mark.
the center of OPN as per standard clearance between column and grating
Comment1 drawing(typical comment) is 20mm. COOEC is to check and
Please integrate details of Comment 4: update.
expansion joint as per Comment 2:
supplementary grating support to be
provide in the direction of bearing bars
L001-12000- Grating to be split on supporting beam as shown in pink color. COOEC is to
CS-2408-4945_R0 and keep overlap length is 32mm as check and update as general comment.
minimun. COOEC is to check and revise
grating panel as highlighted in green Grating overlap with base plate of
color. post,COOEC is to check and revise to
keep 20mm clearance between base
plate of post and grating.