You are on page 1of 4

PageWriter TC10

A portable
workflow solution
with DXL clincal decision support.

The Philips PageWriter TC10 cardiograph is portable, affordable and Key advantages
• Portable size,
easy to operate. It supports advanced PageWriter cardiograph features, lightweight design,
scalable network connectivity, and the world-class Philips DXL and a convenient
handle for easy use in
ECG algorithm. nearly any care setting
• Easy 1-2-3 touch
Quickly download worklists and patient demographics with wireless operation with
LAN via standard XML, HL7 and DICOM communications. Easily the Philips DXL
ECG algorithm
retrieve ECG orders from your current DICOM MWL provider
• Automated workflow
and store resulting DICOM-format ECGs to your existing PACS. with one-button
push via XML, HL7,
The intuitive 1-2-3 touchscreen lets physicians, technicians, nurses, and DICOM

and assistants efficiently acquire, analyze, store, print, and access ECGs.
With its compact size and lightweight design, the PageWriter TC10 is
DXL
a portable workflow solution that supports patient needs in a wide
range of care settings.
Technical specifications
PageWriter TC10 Cardiograph (860392)

ECG functions Advanced bi-directional network communications*


Simultaneous lead 12 leads Central time Time can be manually or automatically
acquisition management (D01) synchronized to a Network Time Server
ECG report • 3 x 4, 3 x 4 3R, 3 x 4 1R, 3 X 4 IR plus ST via IntelliSpace ECG or IntelliBridge
via TC10 printer Maps, 6 x 2 Enterprise**
• Standard and Cabrera format, plus Pan Orders worklist (D01) • Download of orders worklist from
12 Cabrera networked server via IBE
Standard • Ten interval, duration, • User-configurable drop down lists (e.g. by
measurements and axis measurements location, user, or shift)
• Configurable QT correction method • Ad-hoc query for specific orders based upon
multiple user-entered or scanned search
Rhythm strips Up to 6 configurable leads
criteria (e.g. Patient ID, Last/First Name)
Disclosure (D05) • Five-minute history of all 12 leads
• Supported by Open Worklist with
• Complete ECG report of any selected
IntelliSpace ECG and select
10 seconds
departmental systems
Event marking (D05) • Six independent events can be marked • Supported by standard HL7 and DICOM
for later review and analysis interface via IntelliBridge Enterprise for
• Event markers appear on ECG reports departmental and hospital systems
Timed ECG Support for pharma stress protocols ADT (D02) • Query and retrieval of patient
Report storage and Full fidelity at 500Hz of 10 seconds for demographic information
transfer all 12 leads • Based upon user-entered or scanned search
Data format PDF and XML criteria (e.g. Patient ID, Last/First Name)
• Supported by standard HL7 interface via
IntelliBridge Enterprise for
hospital systems
DXL ECG Algorithm (D03)
Last ECG (D06) • Automatic retrieval of previous ECG or
Interpretive statements • >600 interpretive statements list of available ECGs for current patient
• Integrated pediatric analysis • Supported by IntelliSpace ECG
Borderline statement Three configurable settings Interactive query • Retrieval of selected ECGs based upon
suppression (D06) user-entered search criteria
Extended • 46 measurements of morphology • Supported by IntelliSpace ECG
measurements analysis in each of the 12 leads Manual orders (D07) Create patient worklists with
• 21 parameters of rhythm analysis complete demographic information
Reasons Selectable explanations of all for later retrieval
interpretive statements
Nomenclature Aligned with 2007 AHA/ACCF/HRS
Recommendations, Part II 1 Signal quality indicators
Leads-off advisory Anatomical lead map displays the
location and label of loose or
STEMI diagnostic aids disconnected leads/electrodes
Graphical ST • Two ECG reports with polar ST Maps Lead color Four colors to indicate quality of
presentation • Frontal and transverse planes individual leads
Age and gender Based upon 2009 AHA/ACCF/HRS LeadCheck Lead-placement software detects 20
criteria (D03) Recommendations, Part VI: Acute different lead reversals
Ischemia/Infarction 2 Heart rate Continuous display of patient heart rate
STEMI-CA • Criteria that suggest any of four probable Print preview Full-screen preview of ECG waveforms
(Culprit Artery) (D03) sites of the occluded coronary artery prior to printing
• Based upon 2009 AHA/ACCF/HRS
Recommendations, Part VI 2
Critical values (D03) Highlights four conditions requiring User training and self help
immediate clinical attention Application help Integrated graphical help for
primary functions
Self-paced training PC-based, interactive, dynamic
animation covering all major
clinical functions
Training mode Integrated waveform simulation
1
AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of
the Electrocardiogram, Part II: Electrocardiography Diagnostic Statement List. J
Am Coll Cardiology, 2007; 49:1128-135. * When networked with select hospital and departmental solutions; refer to
2
AHA/ACCF/HRS Recommendations for the Standardization and Interpretation supplier specifications
of the Electrocardiogram, Part VI: Acute Ischemia/Infarction. Circulation, 2009; **IntelliSpace ECG and/or IntelliBridge Enterprise are not included with the product
119:e262-e270. and must be purchased separately.
Technical specifications
PageWriter TC10 Cardiograph (860392)

User interface
Presentation filters – 10 sec reports
Touch screen • 1-2-3 operation High pass 0.05, 0.15, and 0.5Hz
• Context-sensitive application
Low pass 40, 100, and 150Hz
• Five-wire, resistive touchscreen

Presentation filters – rhythm


Display
High pass 0.05 and 0.15Hz
Size 7 inch touch screen
Low pass 40, 100, and 150Hz
Resolution 800 x 480 pixels
Colors 64K colors
Electrical
Battery Lithium ion
Patient connections
Battery capacity • 11.1V@4800mAH
Patient cable Acquire data at 8,000 samples/second • 300 typical patient reports (3x4 3R
on each patient connection format without measurement and
Long patient cable Extended-length lead wires allow interpretation), or
(H23) considerable distances between the • 120 minutes 6-lead rhythm printing
patient cable and the patient connections (10 Hz, 1 mV signals), or
• 10 hours continuous operation
without printing
End connectors (adaptors) Battery recharge <4 hours (standby/off mode or run mode
Alligator clips (E01) Alligator clips for tab electrodes without printing)
Main power 100-240VAC, 50/60Hz
Wide tab Flat adaptor for tab electrodes reduces
(E02) twisting (AAMI only) Power consumption 60W max
Welsh bulbs (E04) Six Welsh bulbs and four limb clamps
Snap/Tab adaptor Fits both snap and tab electrodes with
(E06) metal on both sides Mechanical
Dimensions 65mm x 338mm x 240mm
(2.6in x 13.3in x 9.4in)
Printer Weight 2.5kg (5.5lb) includes battery
Resolution High-resolution, digital-array printer using
thermal-sensitive paper; 200dpi (voltage
axis) by 500dpi (time axis) at 25mm/sec Environmental
Operating conditions • 10°C to 40°C (50°F to 104°F)
• 10% to 90% relative humidity
Connectivity (non-condensing)
Wireless LAN (D23) 802.11(a/b/g) • Up to 3,048m (10,000ft) altitude
Internal storage (D06) 200 ECGs Storage conditions • -20°C to 50°C (-4°F to 122°F)
• 10% to 90% relative humidity
External storage (D06) 200 ECGs with optional USB device
(non-condensing)
• Up to 4,572m (15,000ft) altitude

Automated data input


Barcode reader • 1D barcode symbology: Code39 Safety and performance
(H12) • Flexible field data entry
International standards • General Requirement for Safety
Barcode reader • 2D barcode symbology: QR Code
and regulations IEC 60601-1: 1988 +A1:1991 +A2:1995
(989803189871)
• Particular Requirement for Safety of
Electrocardiographs
IEC 60601-2-25: 1993 + A1:1999
Pre-processing filters • Particular Requirements for Safety
AC noise 50 or 60Hz IEC 60601-2-51: 2003
Signal processing Artifact Rejection and Baseline Wander • US General Requirements for Safety
UL 60601-1: 2003
• Diagnostic Electrocardiographic Devices
AAMI EC11 : 1991(R) 2001 /(R)
• CAN/CSA-C22.2 No. 601.1-M90 2007
• Electromagnetic compatibility
IEC60601-1-2: 2001, +A1:2004
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice. 4522 991 06321 • SEP 2014
Trademarks are the property of Koninklijke Philips N.V.
(Royal Philips) or their respective owners. www.philips.com/pagewriter/tc10

You might also like