Professional Documents
Culture Documents
Contents
Construction 4
Function
General product characteristics
Approvals
Sensor versions 5
General characteristics 6
Accuracy characteristics
Typical applications 7
Technical data 8 – 10
Type key 11
Electrical connections 12
Signal characteristics
Electrical characteristics 13
IO-Link 14
3
Gear type flow meters
VC
Description
I Construction I Function
4 1 Housing
2 Cover
3 Gear
4 Plug
5 Sensor
6 Bearing
6 3
5
2
IO-Link International
4
Gear type flow meters
VC
Description
I Standard version
The standard versions come with an integrated
pre-amplifier which converts the pulses from the mag-
netic sensors into square-wave signals which are then
computed by an electronics into specific measurement
values.
The optionally available remote-electronics version is
designed to handle extreme temperature ranges.
5
Gear type flow meters
VC
Technical data
I General characteristics
I Accuracy characteristics
• The indicated measurement accuracy refers to the • The measurement accuracy tests performed can be
pulse volume, i.e. the percentage variance applies traced to DAkkS (Deutsche Akkreditierungsstelle,
to the latest measurement value. German Accreditation Body).
• The measurement accuracy is up to +/- 0.3% of the • The measurement accuracy characteristics indicat-
measured value by default. ed by KRACHT is confirmed by DAkkS.
• Repeatability is +/- 0.05% in stable conditions. • A calibration is possible on request. The result of
this calibration will be documented in the form of a
measurement accuracy characteristic.
+ 0.3%
+ 0.05%
- 0.3%
Repeatability
Flow
6
Gear type flow meters
VC
Technical data
I Application examples
Specifications (type
Typical Typical application of the flow/
key ID for bearing and Typical media
media characteristics volume measurement
material)
Oil
Hydraulic systems
Braking fluid lubricating fluids
K1 Test bench construction
Diesel low to medium viscosity
Cylinder stoke measurement
Skydrol
offset ink
polyol
isocyanate lubricating fluids consumption measuring
G1
glue medium to high viscosity (printing machines)
resin
silicone
polyol
isocyanate
poor lubricating fluids Ratio control
G2 glue
medium to high viscosity (2-component systems)
resin
silicone
dosing control
clear varnish lubricating fluids
K2 (paint-spray lines)
cavity sealing wax low to medium viscosity
test bench construction
flow measurement
urea (adBlue)
poor lubricating fluids (paint-spray lines)
H2 solvents
low viscosity test bench construction
petrol
dosing
oil
braking fluid lubricating fluids applications of up to 480 bar for
K3
diesel low viscosity nominal sizes 3 and 5
Skydrol
oil
K4 diesel low viscosity flow measurement
water
7
Gear type flow meters
VC
Technical data
I Overview
Standard • • • • • • • •
High-temperature • • – – • • • –
ATEX • • • • • • • •
IO-Link • • • • • • • •
Encoder • – • – – – – –
High-temperature PLUS • • – – – • • –
ATEX high-temperature PLUS • • – – – • • –
Low-temperature – • – – – – – –
I Operating characteristics
Nominal size Starting point Measuring range
l/min l/min
0.025 0.001 0.008 ... 2 0.008 ... 2 – 0.02 ... 2 – 0.008 ... 2 – –
0.04 0.004 0.02 ... 4 0.02 ... 4 – – – 0.02 ... 4 – –
0.1 0.008 0.04 ... 8 0.04 ... 8 0.04 ... 8 – – 0.04 ... 8 – –
0.2 0.01 0.16 ... 16 0.16 ... 16 0.16 ... 16 0.16 ... 16 0.16 ... 16 0.16 ... 16 – 0.2 ... 12
0.4 0.01 0.2 ... 40 – 0.2 ... 30 0.2 ... 30 – – – –
1 0.02 0.4 ... 80 0.4 ... 80 0.3 ... 60 0.3 ... 60 0.4 ... 80 0.4 ... 80 – –
3 0.03 0.6 ... 160* 0.6 ... 160* 0.6 ... 100* 0.6 ... 100* 0.6 ... 160* – 0.6 ... 160 –
5 0.04 1.0 ... 250* 1.0 ... 250* 1.0 ... 160* 1.0 ... 160* 1.0 ... 250* – 1.0 ... 250 –
12 0.1 2.0 ... 600 – – – – – – –
16 0.2 3.0 ... 700 – – – – – – –
* Maximum pressure 350 bar
VgZ in cm 3
0.025 0.040 0.100 0.245 0.400 1.036 3.000 5.222 12.000 16.000
Resolution in pulse/l* 40,000.00 25,000.00 10,000.00 4,081.63 2,500.00 965.25 333.33 191.50 83.33 62.50
8
Gear type flow meters
VC
Technical data
I Encoder version resolution
Nominal size Sensor resolution* Pulse volume Resolution Measured value Pulse frequency with
resolution Qmax
4-fold**
pulse/rev cm³/pulse pulse/l pulse/l Hz
Electronics Standard Reduced High ATEX IO-Link without Encoder** High ATEX version Low
version supply tempera- version pre- tempera- High tempera-
voltage ture amplifier ture PLUS temperature ture
12 V PLUS
Type key ID S R H X L V E K KX T
EPDM -40 ... 120 -40 ... 150 -30 ... 80 -40 ... 80 -40 ... 120 -20 ... 80 –
FFKM -15 ... 120 -15 ... 150 -15 ... 80 -15 ... 120 -15 ... 80 -15 ... 210 -15 ... 200 –
9
Gear type flow meters
VC
Selection guide
Medium temperature in °C
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220
Bearing
K ball bearing
Material: housing
1/3 spheroidal cast iron
2 stainless steel
4 aluminium
Sealing material
F FKM
E EPDM
P FEP
K FFKM
Q FVMQ
Electronics versions
with internal electronics S standard
H high-temperature
X ATEX/IECEx
L IO-Link
E encoder
T low-temperature
VC 1 K 1 F 1 P 2 S H
-60 -40 -20 0 20 40 60 80 100 120 140 160 180 200 220
K ball bearing
F FKM
S standard
10
Gear type flow meters
VC
Type key
Example
VC 1 K 1 F 1 P 2 S H
1 2 3 4 5 6 7 8 9 11
1 Product
2 Nominal size
0.025 0.04 0.1 0.2 0.4 1 3 5 12 16
3 Bearing
K H C G
ball bearing hybrid ball bearing ball bearing, high tolerance carbide plain bearing
4 Material
1 2 3 4
housing spheroidal housing stainless steel housing spheroidal housing aluminium
cast iron GJS-400 gears stainless steel cast iron GJS-600 (only nominal size 0.2)
gears steel gears steel
5 Sealing
F E P K Q
FKM EPDM FEP FFKM FVMQ
6 Surface
1 2 3
standard (coated) Skydrol-resistant coating without coating
7 Connection type
P R
plate mounting pipe connection
8 Sensors Note
2 2 sensors
1 1 sensor
3 without sensors
4 2 sensors vibration-proof/condensation-proof
5 encoder only nominal sizes 0.01 · 0.04 · 0.2 · 1 Pos. 9: only with E
10 Cable length
2 5 10
without cable between flow meter with 2 m cable with 5 m cable with 10 m cable
and electronics
11
Gear type flow meters
VC
Electronics
I Electric connections
Standard and high-temperature version High-temperature PLUS and low-temperature version
Connection plug arrangement (M12x1 4-pole round connector)
1: UB (brown) 1: UB (brown)
1
2 2: Channel 1 (green) 2: Channel 1 (white)
3 2 1
4 3: Channel 2 (yellow) 3: 0 Volt (blue)
3 4
4: 0 Volt (white) 4: Channel 2 (black)
1: UB
2 1 A: UB (brown)
2: channel 1 A
3 4 B: Channel 1 (green)
3: 0 Volt B
C C: Channel 2 (yellow)
4: channel 2 D
D: 0 Volt (white)
IO-Link version
Connection plug arrangement (M12x1 metal/4-pole round connector)
1: brown UB
3: blue 0 Volt
3 4
4: black C/Q channel 2
90°
12
Gear type flow meters
VC
Electronics
I Standard versions electrical characteristics
Working voltage UB 24 V +/- 20% or 12 V +/- 20% for versions with reduced supply voltage
Pulse shape with symmetrical output signal Square wave, duty factor/channel 1:1 ± 15%
Protection rating IP 65
Working voltage UB 9 … 36 V
Protection rating IP 65
13
Gear type flow meters
VC
Electronics
I IO-Link
Thanks to its international standardisation (IEC 61131- IO-Link connection plug
9), the IO-Link technology offers point-to-point con-
nectivity with continuous monitoring between any
desired control layer and the VC-IO-Link assembly. L3
Handling and startup is made easy by the associated L1 L2
IODD (IO Device Description) file.
IO-Link characteristics
Name VC
Manufacturer ID 0x0524
Device ID 0x000001
Name of manufacturer Kracht GmbH
IO-Link connection plug V1.1
Bit rate COM3 / 230.4 kbit/s
Minimum cycle time 500μs
SIO mode supported Yes
Indexed service data unit Yes
used (IS DU)
Data storage (DS) possible Yes
SIO mode
SIO mode
– Same output of the two square-wave signals as in
M12x1 standard pre-amplifier
IO-Link mode
IO-Link mode
3.0 3.1 2.9 3.1 3.0 3.1 Signal output as described in the IODD according to the
following units:
– number of pulses
– litres
...
14
Gear type flow meters
VC
17 ATEX E 106 X / BVS 17.0088X CML 16 ATEX 2014X / IECEx CML 16.0011
Notes
This drawing only serves as an example for the connection of the sensors to the isolating switching amplifier K 130. Observe the applicable
standards when assembling a plant in an explosive atmosphere.
Ignition protection marking (device-dependent)
II 2G Ex ia IIC T4 Gb
II 2D Ex ia IIIC T135 °C Db
15
Gear type flow meters
VC
Pressure drop
12 000
80000
00
00
00
00
00
00
50 0
00
3000
0
0
0
20
10
30
20
10
16
16
60
30
16
14
600
Pressure drop Δp in bar
12
10
100
8 300
4 100
2 20
5 20
0 5
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 0.0 0.1 0.2 0.3 0.4 0.5
Flow rate Q in l/min Flow rate Q in l/min
00
00
00
00
00
50 00
2000
50 0
3000
0
0
0
0
10
30
20
10
60
80
16
60
30
16
14
Pressure drop Δp in bar
12
10 100
300
8
4 20
2 100
5
20
0 5
0.0 0.5 1 1.5 2 2.5 3 3.5 4.0 0.0 0.2 0.4 0.6 0.8 1.0
Flow rate Q in l/min Flow rate Q in l/min
12 00
80 0
00
00
00
00
00
00
00
5000
00
0
0
0
30
10
50
30
20
16
16
60
30
16
14
Pressure drop Δp in bar
12 1000
10
100
8
6 600
4 20 300
2 5
100
0 5
0 1 2 3 4 5 6 7 8 9 10 0.0 0.4 0.8 1.2 1.6 2
Flow rate Q in l/min Flow rate Q in l/min
16
Gear type flow meters
VC
Pressure drop
0
80000
0
00
00
00
00
00
50 00
00
00
00
00
0
30
20
80
50
30
16
16
12
10
60
16
2000
14
Pressure drop Δp in bar
12
10 300
8 1000
6
100
600
4
20
2 5 300
100
20
0 5
0 2 4 6 8 10 12 14 16 0 1 2 3 4
Flow rate Q in l/min Flow rate Q in l/min
12 0
00
00
00
00
00
00
00
50 00
00
00
30 0
0
0
20
10
80
50
30
20
16
16
60
30
16
14
1000
Pressure drop Δp in bar
12
100
10
8 600
20
6 5
4
300
2 100
20
0 5
0 5 10 15 20 25 30 35 40 0 1 2 3 4 5 6 7 8 9 10
Flow rate Q in l/min Flow rate Q in l/min
VC 1 VC 1 (section)
80 00
0
0
00
00
00
00
00
00
00
00
5000
30 0
00
0
0
20
10
50
30
20
16
16
80
12
60
30
16
14
Pressure drop Δp in bar
12 100
1000
10
8 20
600
5
6
4 300
2 100
20
5
0
0 10 20 30 40 50 60 70 80 0 4 8 12 16 20
Flow rate Q in l/min Flow rate Q in l/min
17
Gear type flow meters
VC
Pressure drop
0
80000
0
30 0
00
00
00
00
00
00
5000
00
00
00
0
0
20
10
50
30
20
16
16
80
12
60
16
300
14
Pressure drop Δp in bar
12 1000
100
10
8
20 600
6
5
4 300
2 100
20
0 5
0 20 40 60 80 100 120 140 160 0 10 20 30 40
Flow rate Q in l/min Flow rate Q in l/min
VC 5 VC 5 (section)
0
12 00
80 0
0
00
00
00
00
00
50 0
00
00
00
00
0
0
20
10
80
50
16
16
30
12
60
16
14
300 3000
Pressure drop Δp in bar
12
10 100
2000
8
20
5
6 1000
4 600
2 300
100
20
5
0
0 25 50 75 100 125 150 175 200 225 250 0 10 20 30 40 50
Flow rate Q in l/min Flow rate Q in l/min
VC 12 VC 12 (section)
12 00
80 0
0
00
00
00
00
00
00
00
50 0
00
00
0
0
20
10
50
16
30
16
80
12
60
30
10
16
20
14
5
Pressure drop Δp in bar
12
3000
10
8 2000
6 1000
4
600
2 300
100
20
5
0
0 60 120 180 240 300 360 420 480 540 600 0 20 40 60 80 100
Flow rate Q in l/min Flow rate Q in l/min
18
Gear type flow meters
VC
Pressure drop
0
80 0
0
00
00
00
00
00
00
00
00
50 0
00
00
0
0
20
10
50
16
30
16
80
12
60
30
10
20
16 5
14
Pressure drop Δp in bar
12
10
3000
8
2000
6
4 1000
600
2 300
100
20
0 5
0 70 140 210 280 350 420 490 560 630 700 0 20 40 60 80 100
Flow rate Q in l/min Flow rate Q in l/min
19
Gear type flow meters
VC
Pressure drop
12 0
80 0
00
00
00
00
00
00
00
00
00
5000
3000
00
0
0
20
10
50
30
20
10
16
16
60
30
16
14
600
Pressure drop Δp in bar
12
10
100
8
300
4 100
20
2
5
20
0 5
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 0.0 0.1 0.2 0.3 0.4 0.5
Flow rate Q in l/min Flow rate Q in l/min
12 00
0
00
00
00
00
00
00
00
00
00
0
0
0
20
10
50
30
20
16
30
16
80
60
30
16
14
Pressure drop Δp in bar
12
1000
10
100
8
600
6
20
4 300
5
2 100
20
0 5
0 1 2 3 4 5 6 7 8 9 10 0.0 0.5 1 1.5 2.0
Flow rate Q in l/min Flow rate Q in l/min
0
00
00
00
00
30 0
00
00
5000
00
0
0
20
10
50
30
16
16
80
12
16 600
2000
14
Pressure drop Δp in bar
12
10 300
8
1000
6
100
600
4
20
2 5 300
100
20
0 5
0 2 4 6 8 10 12 14 16 0 1 2 3 4
Flow rate Q in l/min Flow rate Q in l/min
20
Gear type flow meters
VC
Pressure drop
0
0
00
00
00
00
00
00
00
00
00
00
00
0
20
10
20
50
30
16
30
16
80
50
12
60
16
14 300
Pressure drop Δp in bar
12
10
1000
8
100 600
6
300
4 20
5
2
100
20
0 5
0 3 6 9 12 15 18 21 24 27 30 0 2 4 6 8 10
Flow rate Q in l/min Flow rate Q in l/min
VC 1 VC 1 (section)
12000
80000
0
0
00
00
00
00
00
00
00
00
00
00
00
0
20
10
50
30
20
16
30
16
80
50
12
60
16
14
Pressure drop Δp in bar
12 300
1000
10
8
100
600
6
20
4 5 300
2 100
20
5
0
0 6 12 18 24 30 36 42 48 54 60 0 4 8 12 16 20
Flow rate Q in l/min Flow rate Q in l/min
VC 3 VC 3 (section)
12 00
80 00
0
00
00
00
00
00
00
00
00
00
0
0
0
20
10
50
30
16
30
16
80
50
12
16
14 2000
Pressure drop Δp in bar
12 600
10
300 1000
8
6
600
100
4
300
20
2 5 100
20
0 5
0 10 20 30 40 50 60 70 80 90 100 0 8 16 24 32 40
Flow rate Q in l/min Flow rate Q in l/min
21
Gear type flow meters
VC
Pressure drop
0
0
0
00
00
00
00
00
00
00
00
00
50
20
16
80
30
16
80
12
12
16
5000
14 1000
Pressure drop Δp in bar
12
600 3000
10
8
300 2000
6
1000
100
4
20 600
5
2 300
100
20
0 5
0 20 40 60 80 100 120 140 160 0 10 20 30 40 50
Flow rate Q in l/min Flow rate Q in l/min
22
Gear type flow meters
VC
23
Gear type flow meters
VC
Dimensions
I Spheroidal cast iron version – plate mounting
Electronics versions: standard / high-temperature / ATEX/IECEx / IO-Link / encoder
A C D F G* J K L M N P MA m
VC 0.025 85 10 60 50 101 - 70 40 20 6.7 M6 14 1.8
VC 0.04 85 9 60 56 107 - 70 40 20 6.7 M6 14 2.0
VC 0.04 / encoder 85 12 60 48 95 9.65 70 40 20 6.7 M6 14 2.0
VC 0.1 85 10 60 55 106 - 70 40 20 9 M6 14 2.5
VC 0.2 85 13 60 57 108 - 70 40 20 9 M6 14 2.0
VC 0.2 / encoder 85 13 60 57 104 10.80 70 40 20 9 M6 14 2.0
VC 0.4 100 17 90 63 114 - 80 38 34 16 M8 35 3.7
VC 1 120 13 95 72 123 15.50 84 72 35 16 M8 35 5.2
VC 1 / encoder 120 16 95 69 116 18.20 84 72 35 16 M8 35 5.4
VC 3** 170 18 120 89 140 46.50 46 95 50 25 M 12 120 9.0
VC 5** 170 22 120 105 156 46.50 46 95 50 25 M 12 120 13.0
* electronics version H: plus 12 mm
electronics version X: plus 6 mm
** does not apply to K3 specification. Dimensions VC 3/VC 5 – see page 27 for K3.
Connection dimensions
O-ring
Connection dimensions
O-ring
Dimensions in mm
24
Gear type flow meters
VC
Dimensions
I Spheroidal cast iron version – plate mounting
Electronics versions: high-temperature PLUS / high-temperature Plus ATEX/IECEx
Nm kg
A C D F G J K L M N P MA m
VC 0.04 85 9 60 56 93 - 70 40 20 6.7 M6 14 2
VC 0.1 85 10 60 55 92 - 70 40 20 9 M6 14 2.3
VC 0.2 85 13 60 57 94 - 70 40 20 9 M6 14 2
Connection dimensions
O-ring
Dimensions in mm
25
Gear type flow meters
VC
Dimensions
I Spheroidal cast iron version – plate mounting – specification K3
Electronics versions: standard / high-temperature / ATEX/IECEx / IO-Link
Nm kg
C D F G* J K L M N P MA m
Connection dimensions
Tightening torque MA
O-ring
Dimensions in mm
26
Gear type flow meters
VC
Dimensions
I Spheroidal cast iron version – plate mounting – specification K3
Electronics versions: high-temperature Plus / high-temperature Plus ATEX/IECEx
Nm kg
C D F G J K L M N P MA m
Connection dimensions
O-ring
Dimensions in mm
27
Gear type flow meters
VC
Dimensions
I Spheroidal cast iron version – plate mounting
Electronics versions: standard / high-temperature / ATEX/IECEx / IO-Link / encoder
Nm kg
C D F G* J K L M N P MA m
Connection dimensions
Tightening torque MA
O-ring
Dimensions in mm
28
Gear type flow meters
VC
Dimensions
I Spheroidal cast iron version – plate mounting – specification K3
Electronics versions: high-temperature Plus / high-temperature Plus ATEX/IECEx
Nm kg
C D F G J K L M N P MA m
Connection dimensions
O-ring
Dimensions in mm
29
Gear type flow meters
VC
Dimensions
I Stainless steel version – plate mounting
Electronics versions: standard / high-temperature / ATEX/IECEx / IO-Link
Nm kg
C D F G* J K L M N P MA m
VC 0.1 10 94 55 106 - 70 40 20 9 M6 14 3
Connection dimensions
Tightening torque MA
O-ring
Dimensions in mm
30
Gear type flow meters
VC
Dimensions
I Stainless steel version – plate mounting
Electronics versions: high-temperature Plus / high-temperature Plus ATEX/IECEx / low-temperature
Nm kg
C D F G J K L M N P MA m
VC 0.025 10 94 55 92 - 70 40 20 6.7 M6 14 3
VC 0.04 9 94 56 93 - 70 40 20 6.7 M6 14 3
VC 0.1 10 94 55 92 - 70 40 20 9 M6 14 3
VC 0.2 13 94 57 94 - 70 40 20 9 M6 14 3.1
Connection dimensions
Tightening torque MA
O-ring
Dimensions in mm
31
Gear type flow meters
VC
Dimensions
I Stainless steel version – pipe connection
Electronics versions: standard / high-temperature / ATEX/IECEx / IO-Link
kg
A B C D E F G* H J K L R m
Connection dimensions
Dimensions in mm
32
Gear type flow meters
VC
Dimensions
kg
e A B C E F G H J K L M N P R c d f m
MVC 0.2 R3 C05* G 1/2 85 90 35 65 76 7 11 7 70 40 20 6.5 M 6/14 deep 17.5 0.7 29 15 1.7
MVC 0. R1 C09 G 1/2 100 110 37 86 96 7 11 7 80 38 34 16 M 8/18 deep 18.5 0.7 29 15 2.7
MVC 1 R2 C05 G 1/2 100 120 37 80 106 7 11 7 84 72 35 12 M 8/18 deep 17.5 0.7 29 15 2.9
MVC 5 R2 G09** G 1 1/2 170 165 100 140 145 9 15 9 46 95 50 25 M 12/24 deep 42 1 58 23 17.8
* suitable for VC 0.025, VC 0.04, VC 0.1, VC 0.2 and VC with 0.2 encoder
** suitable for VC 3 and VC 5
Dimensions in mm
33
Gear type flow meters
VC
Dimensions
MVC 0.4 R1 C08 G 1/2 100 110 37 86 96 7 11 7 80 38 34 16 M 8/18 deep 46 0.7 29 15 2.5
MVC 1 R2 C04 G 1/2 100 120 37 80 106 7 11 7 84 72 35 12 M 8/18 deep 50 0.7 29 15 2.7
Dimensions in mm
34
Gear type flow meters
VC
Dimensions
I Connection plates (spheroidal cast iron) with lateral SAE flange connection
for VC 3 and 5 in K3 specification
Ordering code Dimensions Weight
kg
B C D E F G K L M N P R a b e f m
MVC 5 V1 E09 150 90 180 110 110 M 8/24 deep 46 95 50 25 M 12/24 deep 50 57.2 27.8 25 M 12/24 deep 14.2
MVC 12 V1 G09 200 140 249 120 140 M 10/20 deep 120 140 70 38 M 20/45 deep 70 79.38 36.5 38 M 16/25 deep 41.18
Dimensions in mm
35
I Gear Pumps
Product Portfolio
Low and high-pressure gear pumps for
lubricating oil, hydraulic, process and test
bench applications, fuel and metering
systems.
I Flow Measurement
Gear, turbine and screw type flow meters
and electronics for volume and flow,
metering and consumption in the chemical
industry, hydraulic, process and test bench
technology.
I Hydraulics
Single and multistage high-pressure gear
pumps, gear motors and valves for
construction machinery, municipal vehicles,
agricultural vehicles, special vehicles and
truck bodies.
I Valves
Cetop valves for all requirements stationary
and mobile applications. Pressure, switching
and stop valves with pipe connection for
high flow rates. Special valves.
VC/EN/09.2021
Errors and technical changes reserved