53M-A

Intelligent
Multifunction Meter
www.cet-global.com
PMC-53M-A PMC-53M-E
PMC-53M-A and PMC-53M-E Measurements
are CET’s latest offer for the low-cost Mul�func- PMC-53M-A PMC-53M-E
�on Digital Meter. Housed in a standard DIN Voltage (ULN/ULL) (per Phase & Avg.) √
form factor measuring 96x96x88mm, Compli- Current (per Phase & Avg.) √
ance with the IEC62053-22 Class 0.5S Standard, Neutral Current (Calculated) √
they are cost effec�ve replacements for 3-phase Frequency √
analog meters and perfectly suited for industrial, Phase Angle √
commercial and u�lity applica�ons for power PF (True & Dispalcement) √

and energy measurement. PMC-53M-A features Opera�ng Time (Running Hours) √

a large, backlit, 7-segment LCD display while the Ac�ve Power (per Phase & Total) √
Reac�ve Power (per Phase & Total) √
PMC-53M-E features a high-contrast LED display.
Apparent Power (per Phase & Total) √
Both op�onally provide four Digital Inputs for
Ac�ve Energy Imp/Exp/Tot/Net
status monitoring, two Relay Outputs for control
Reac�ve Energy (4 Quadrant) Imp/Exp/Tot/Net
and alarm applica�ons as well as one standard
Apparent Energy Total
RS-485 port with Modbus RTU Protocol support.
Max./Min. of Instantaneous Values With Timestamp
These features make them the most affordable
Demand (kW, kvar, KVA, I), Predicted & Peak With Timestamp
smart metering devices for any Energy Manage- LED Pulse Output 1
1 LED Pulse Output
Setpoints 9 (24 parameters for selec�on)
ment System. Enclosure 2
1 4 1 6 2 Enclosure U/I Fundamental √ N/A
3 Phase Indicator
Front Panel 3

Power Quality
2 5 2
7 4 Front Panel
Communica�on Indicator 4 3

Typical Applica�ons
6 5 Energy Indicators
Units 5
3
Measurements 6
4 8 6 Communica�on Indicator PMC-53M-A PMC-53M-E
Bu�ons 7 7
5 7 Measurements THD Voltage & Current (per Phase) √
9
▪ Industrial, Commercial and U�lity Substa�on Metering 8 Parameters TOHD Voltage & Current (per Phase) √
▪ Building, Factory and Process Automa�on 9 Bu�ons TEHD Voltage & Current (per Phase) √
▪ Sub-metering and Cost Alloca�on
▪ Energy Management and Power Quality Monitoring PMC-53M-A PMC-53M-E Individual Harmonics
U/I Symmetrical Components √ (Via Comm. Only)
2nd - 31st
N/A
K-Factor √ √ (Via Comm. Only)
Crest Factor √ √ (Via Comm. Only)

General TDD (Odd/Even/Total) √ √ (Via Comm. Only)

Dimension
U/I Unbalance √ √ (Via Comm. Only)
PMC-53M-A PMC-53M-E
Unit: mm Power Supply
Accuracy Class (kWh)
95-250VAC/DC, ±10%
Class 0.5S SOE Log
Accuracy for Voltage and Current ±0.2% Reading + 0.05% F.S. PMC-53M-A PMC-53M-E
.8
+0 0 Voltage Input 400ULN/690ULL, Range: 10V to 1.2Un SOE 100 entries 64 entries
92
Current Input 1A/5A, Range: 0.1%-200%In

91
.5 Humidity Condi�ons
Opera�ng Temperature (°C)
5% to 95% non-condensing
-25°C to 70°C
Communica�ons
Storage Temperature (°C) -40°C to 85°C Protocol Modbus RTU
96
+0.8

RS-485 Port 1 (max. 38,400 bps)


92 0

Atmospheric Pressure 70 kPa to 106 kPa


91.5

Unit Dimensions/Panel Cutout (mm) 96x96x88 mm / 92x92 mm (3.62”x3.62”)


Measurement Category
True RMS Sampling Rate (samples/cycle)
CAT III up to 600 ULL Input/Output
64
Digital Input (Op�onal) 4xDI (Dry contact, 24VDC internally we�ed)
Ba�ery-backed Real-�me Clock 25ppm accuracy (<2s per day)
13.2 Digital Output (Op�onal) 2xDO (Form A Mechanical Relay, 5A @ 250VAC or 30VDC)
96
IP Ra�ng IP65
67 kWh & kvarh Pulse Output (LED) √
7
Display Backlit, 7-segment LCD Display High-contrast LED Display
Communica�on Indicator (LED) √
Accuracy Standards of Compliance
Parameters Accuracy Resolu�on Safety Requirements
Voltage ±0.2% Reading + 0.05% F.S. 0.001V EN61010-1: 2010
CE LVD 2014/35/EU
EN61010-2-030: 2010
Current ±0.2% Reading + 0.05% F.S. 0.001A
UL 61010-1 Ed. 3
kW, kvar, kVA ±0.5% Reading + 0.05% F.S. 0.001kX CAN/CSA C22.2 NO. 61010-1-12 Ed. 3
kWh, kVAh IEC62053-22 Class 0.5S 0.01kXh UL 61010-2-030 Ed. 2
cULus Listed
0.01kvarh 0.1kvarh CSA C22.2 NO. 61010-2-030: 18 Ed. 2
kvarh IEC62053-23 Class 2 UL 61010-2-201 Ed. 2
(53M-A) (53M-E)
PF ±0.5% 0.001 CSA C22.2 NO. 61010-2-201 Ed. 2
Frequency ±0.02Hz 0.01Hz Electrical Safety in Low Voltage
Distribu�on Systems Up to IEC61557-12: 2018 (PMD)
THD IEC61000-4-7 Class B 0. 001% 1000Vac and 1500 Vdc
K-Factor IEC61000-4-7 Class B 0. 001
Insula�on
Phase Angle ±1° 0.1° AC Voltage: 2.5kV @ 1 minute IEC62052-11: 2003
Insula�on Resistance: >100MΩ IEC62053-22: 2003
Impulse Voltage: 6kV, 1.2/50μs

Technical Specifications Emission Tests


Voltage Inputs (V1, V2, V3, VN) Limits and Methods of Measurement of
Electromagne�c Disturbance Characteris�cs EN55011: 2016
Standard Un 400ULN/690ULL of Industrial, Scien�fic And Medical
Range 10V to 1.2Un (ISM) Radio-Frequency Equipment
Overload 1.2xUn con�nuous, 2xUn for 1s Limits and Methods of Measurement of
Radio Disturbance Characteris�cs of EN55032: 2015
Burden <0.02VA per phase
Informa�on Technology Equipment
Measurement Category CAT III up to 600ULL
Limits for Harmonic Current Emissions
Frequency 45-65Hz
for Equipment with Rated EN61000-3-2: 2014
Current ≤16A
Current Inputs (I11, I12, I21, I22, I31, I32) Limita�on of Voltage Fluctua�ons and
Flicker in Low-Voltage Supply Systems EN61000-3-3: 2013
Standard In 5A (5A/1A Auto-Scaling) for Equipment with Rated Current ≤16 A
Range 0.1% to 200% In Emission Standard for Industrial
EN61000-6-4: 2007 + A1: 2011
Star�ng Current 0.1% of In Environments
Overload 2xIn con�nuous, 20xIn for 1s
Measurement Category CAT III up to 600ULL
Burden <0.15VA per phase Ordering Information
Power Supply (L+, N-) Product Code Descrip�on
A 7-Segment LCD, RS-485 with Modbus
Standard 95-250VAC/DC, ±10%, 47-440Hz PMC-53M
Burden <2W E Mul�func�on Measurements, LED Display
5A/1A Auto-Scaling
Overvoltage Category CAT III up to 300ULN Input Current 5
(Class 0.5S for 5A and Class 1 for 1A)
Input VoItage 9 400ULN/690ULL
Environmental Condi�ons Power Supply 2 95-250 VAC/DC, 47-440Hz
Opera�ng Temp. -25°C to 70°C Frequency 5 45Hz-65Hz
Storage Temp. -40°C to 85°C X None
I/O
Humidity 5% to 95% non-condensing B* 4×DI + 2×DO
Atmospheric Pressure 70 kPa to 106 kPa Communica�ons A 1×RS-485
Language E English
A PMC-53M-A-5925XAE (LCD Standard Model)
Mechanical Characteris�cs PMC-53M 5 9 2 5 X A E
E PMC-53M-E-5925XAE (LED Standard Model)
Panel Cutout 92x92 mm (3.62”x3.62”)
Unit Dimensions 96x96x88 mm
IP Ra�ng 65

Electromagnetic Compatibility Copyright © CET Inc. All rights reserved.


CE EMC Directive 2014/30/EU (EN61326: 2013)
Immunity Tests
Electrosta�c Discharge EN61000-4-2: 2009
Your Local Representative

Radiated Fields EN61000-4-3: 2006 + A1: 2008 + A2: 2010


Fast Transients EN61000-4-4: 2012
Surges
Surges EN61000-4-5: 2014
V.00 07.07.2021

Conducted Disturbances EN61000-4-6: 2014


Magne�c Fields EN61000-4-8: 2010
Voltage Dips and Interrup�ons EN61000-4-11: 2004
Oscillatory Waves EN61000-4-12: 2006
Radio Disturbances CISPR 22: 2006 Class B
Ring Wave EN61000-4-12: 2017

You might also like