You are on page 1of 203

BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Reference: rev_15!A9:T700

Actuator /
Input Device /
DispTC - Display Trouble BFMI - BOMAG Failure Fault Reaction BSPN - BOMAG Suspect
Fault Description Sensor Device
Code Mode Identifier # Control Unit Parameter Number
Decribes how the machine / Device tag used in the electric
Brief description of the
4 digit code shown in the Numerical infromation subsystem reacts in case of Control unit which detects the fault Describes the location of
fault circuit diagram
display about the type of the fault an fault occurence the detected fault

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
510 ERR_ENGINE_RELAY_SHUTDOWN_UB esFunctionInterference A34 K22 Relay, shut off solenoid engine

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:2 - 5003
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

BFMI - BOMAG Failure Terminal Display Code for Diagnosis


Causes Solutions Signal
Mode Identifier Text Comment
Terminal for measurement Display code which can be
Possible causes for the fault Possible solutions for Signal in case a dedicated
Textual infromation about and link in the electric Additional information used for fault related
occurence trouble shooting device is not avialable measures
the type of the fault circuit diagram

_error_list_BF800C_2015_06_12.xls 1 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1001 ERR_PROPEL_BRAKE_LINE_BREAK esEngineOff A34 Y04 Solenoid valve, brake

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:45 - 1001
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1002 ERR_PROPEL_BRAKE_GND esEngineOff A34 Y04 Solenoid valve, brake

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:45 - 1001
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1003 ERR_PROPEL_BRAKE_UB esEngineOff A34 Y04 Solenoid valve, brake

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:45 - 1001
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 2 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1011 ERR_WARN_BUZZER_GND esFunctionInterference A34 H07 Warning buzzer

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:3 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1012 ERR_WARN_BUZZER_UB esFunctionInterference A34 H07 Warning buzzer

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:3 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1016 ERR_PROPEL_RELAY_BACKUP_ALARM_GND esPartialError A34 H14 Back-up alarm buzzer

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:51 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 3 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1017 ERR_PROPEL_RELAY_BACKUP_ALARM_UB esFunctionInterference A34 H14 Back-up alarm buzzer

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:51 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1020 ERR_PROPEL_POTI_PROPEL_SPEED_LINE_BREAK_UB_REFERENCE esPartialError A34 R07 Potentiometer, speed control

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:9 __R07_Reference_Out 1012
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1021 ERR_PROPEL_POTI_PROPEL_SPEED_LINE_BREAK_GND_REFERENCE esPartialError A34 R07 Potentiometer, speed control

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:9 __R07_Reference_Out 1012
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 4 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1022 ERR_PROPEL_POTI_PROPEL_SPEED_CORRELATION esPartialError A34 R07 Potentiometer, speed control

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric Change setting for speed potentiometer type
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1025 ERR_PROPEL_POTI_PROPEL_SPEED_LINE_BREAK_UB_PRINCIPAL esPartialError A34 R07 Potentiometer, speed control

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:8 __R07_Principal_Out 1010
Causes Comment
C1 Bad connection in harness, connector or central electric 0
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1026 ERR_PROPEL_POTI_PROPEL_SPEED_LINE_BREAK_GND_PRINCIPAL esPartialError A34 R07 Potentiometer, speed control

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:8 __R07_Principal_Out 1010
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 5 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1031 ERR_PROPEL_CRAWLER_SPEED_SENSOR_LEFT esFunctionInterference A34 B109 Speed sensor, crawler / wheel motor rear left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


8 Abnormal frequency or pulse width or period X35:34 - 1042
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1032 ERR_PROPEL_CRAWLER_SPEED_SENSOR_RIGHT esFunctionInterference A34 B110 Speed sensor, crawler / wheel motor rear right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


8 Abnormal frequency or pulse width or period X35:35 - 1043
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1033 ERR_PROPEL_SLOPE_SENSOR_LINE_BREAK esFunctionInterference A34 B56 Slope sensor

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X71:12 - 1004
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 6 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1034 ERR_PROPEL_SLOPE_SENSOR_CURRENT_TO_HIGH esFunctionInterference A34 B56 Slope sensor

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X71:12 - 1004
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1050 ERR_PROPEL_SWITCH_DIRECTION_PLAUSIBILITY esPartialError A34 S221 Travel lever

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect X35:14, X35:15, X35:16 - 1029
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1051 ERR_PROPEL_SWITCH_STOP_BRAKE_PLAUSIBILITY esPartialError A34 S04 Switch, brake

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect X35:40, X35:41 - 1032
Causes Comment
C1 Bad connection in harness, connector or central electric Check that the switch contacts are mounted properly on the switch actuation.
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 7 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1070 ERR_PROPEL_PUMP_LEFT_FORWARD_LB esPartialError A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1071 ERR_PROPEL_PUMP_LEFT_FORWARD_SHORT_UB esEngineOff A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1072 ERR_PROPEL_PUMP_LEFT_FORWARD_SHORT_GND esPartialError A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 8 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1073 ERR_PROPEL_PUMP_LEFT_FORWARD_LB_FG esPartialError A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1074 ERR_PROPEL_PUMP_LEFT_FORWARD_SHORT_UB_FG esEngineOff A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1075 ERR_PROPEL_PUMP_LEFT_FORWARD_SHORT_GND_FG esPartialError A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 9 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1076 ERR_PROPEL_PUMP_LEFT_FORWARD_CONTROLLER1 esEngineOff A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1077 ERR_PROPEL_PUMP_LEFT_FORWARD_CONTROLLER2 esEngineOff A34 Y16 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:46 - 1071
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1080 ERR_PROPEL_PUMP_LEFT_BACKWARD_LB esPartialError A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 10 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1081 ERR_PROPEL_PUMP_LEFT_BACKWARD_SHORT_UB esEngineOff A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1082 ERR_PROPEL_PUMP_LEFT_BACKWARD_SHORT_GND esPartialError A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1083 ERR_PROPEL_PUMP_LEFT_BACKWARD_LB_FG esPartialError A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 11 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1084 ERR_PROPEL_PUMP_LEFT_BACKWARD_SHORT_UB_FG esEngineOff A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1085 ERR_PROPEL_PUMP_LEFT_BACKWARD_SHORT_GND_FG esPartialError A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1086 ERR_PROPEL_PUMP_LEFT_BACKWARD_CONTROLLER1 esEngineOff A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 12 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1087 ERR_PROPEL_PUMP_LEFT_BACKWARD_CONTROLLER2 esEngineOff A34 Y17 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:47 - 1076
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1090 ERR_PROPEL_PUMP_RIGHT_FORWARD_LB esPartialError A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1091 ERR_PROPEL_PUMP_RIGHT_FORWARD_SHORT_UB esEngineOff A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 13 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1092 ERR_PROPEL_PUMP_RIGHT_FORWARD_SHORT_GND esPartialError A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1093 ERR_PROPEL_PUMP_RIGHT_FORWARD_LB_FG esPartialError A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1094 ERR_PROPEL_PUMP_RIGHT_FORWARD_SHORT_UB_FG esEngineOff A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 14 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1095 ERR_PROPEL_PUMP_RIGHT_FORWARD_SHORT_GND_FG esPartialError A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1096 ERR_PROPEL_PUMP_RIGHT_FORWARD_CONTROLLER1 esEngineOff A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1097 ERR_PROPEL_PUMP_RIGHT_FORWARD_CONTROLLER2 esEngineOff A34 Y72 Solenoid valve, travel direction forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:48 - 1081
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 15 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1100 ERR_PROPEL_PUMP_RIGHT_BACKWARD_LB esPartialError A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1101 ERR_PROPEL_PUMP_RIGHT_BACKWARD_SHORT_UB esEngineOff A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1102 ERR_PROPEL_PUMP_RIGHT_BACKWARD_SHORT_GND esPartialError A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 16 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1103 ERR_PROPEL_PUMP_RIGHT_BACKWARD_LB_FG esPartialError A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1104 ERR_PROPEL_PUMP_RIGHT_BACKWARD_SHORT_UB_FG esEngineOff A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1105 ERR_PROPEL_PUMP_RIGHT_BACKWARD_SHORT_GND_FG esPartialError A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 17 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1106 ERR_PROPEL_PUMP_RIGHT_BACKWARD_CONTROLLER1 esEngineOff A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1107 ERR_PROPEL_PUMP_RIGHT_BACKWARD_CONTROLLER2 esEngineOff A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:49 - 1086
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1110 ERR_PROPEL_PUMP_START_CURRENTS_NOT_LEARNED esWarning A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


13 Out of calibration X35:49 - 1086
Causes Comment
C1 Calibration procedure not done -
C2 -
C3 -

Solutions
S1 Perform dedicated calibration procedure
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 18 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1111 ERR_PROPEL_PUMP_LEARN_START_CURRENT_LEFT_FORWARD esWarning A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions X35:49 - 1086
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1112 ERR_PROPEL_PUMP_LEARN_START_CURRENT_LEFT_BACKWARD esWarning A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions X35:49 - 1086
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1115 ERR_PROPEL_PUMP_START_CURRENTS_NOT_TAUGHT esWarning A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


13 Out of calibration X35:49 - 1086
Causes Comment
C1 Calibration procedure not done -
C2 -
C3 -

Solutions
S1 Perform dedicated calibration procedure
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 19 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1116 ERR_PROPEL_PUMP_TEACH_START_CURRENT_RANGE_FORWARD esWarning A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions X35:49 - 1086
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1117 ERR_PROPEL_PUMP_TEACH_START_CURRENT_RANGE_BACKWARD esWarning A34 Y73 Solenoid valve, travel direction backward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions X35:49 - 1086
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1120 ERR_PROPEL_VALVE_HYDR_GEAR_LEFT_LINE_BREAK esPartialError A34 Y197 Solenoid valve, hydraulic gear

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:20 - 1050
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 20 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1121 ERR_PROPEL_VALVE_HYDR_GEAR_LEFT_SHORT_GND esPartialError A34 Y197 Solenoid valve, hydraulic gear

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:20 - 1050
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1122 ERR_PROPEL_VALVE_HYDR_GEAR_LEFT_SHORT_UB esPartialError A34 Y197 Solenoid valve, hydraulic gear

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:20 - 1050
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1125 ERR_PROPEL_VALVE_HYDR_GEAR_RIGHT_LINE_BREAK esPartialError A34 Y198 Solenoid valve, hydraulic gear

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:21 - 1051
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 21 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1126 ERR_PROPEL_VALVE_HYDR_GEAR_RIGHT_SHORT_GND esPartialError A34 Y198 Solenoid valve, hydraulic gear

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:21 - 1051
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
1127 ERR_PROPEL_VALVE_HYDR_GEAR_RIGHT_SHORT_UB esPartialError A34 Y198 Solenoid valve, hydraulic gear

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:21 - 1051
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
2012 ERR_PROPEL_STEER_TRANSDUCER_SIGNAL_JUMP esPartialError A34 A45 Steering unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 22 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
2013 ERR_PROPEL_STEER_TRANSDUCER_LINE_BREAK_PRINCIPAL esPartialError A34 A45 Steering unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:6 __A45_Principal_Out 2001
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
2014 ERR_PROPEL_STEER_TRANSDUCER_LINE_BREAK_REFERENCE esPartialError A34 A45 Steering unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:7 __A45_Reference_Out 2003
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
2015 ERR_PROPEL_STEER_TRANSDUCER_CURRENT_TO_HIGH_PRINCIPAL esPartialError A34 A45 Steering unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:6 __A45_Principal_Out 2001
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 23 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
2016 ERR_PROPEL_STEER_TRANSDUCER_CURRENT_TO_HIGH_REFERENCE esPartialError A34 A45 Steering unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:7 __A45_Reference_Out 2003
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
2017 ERR_PROPEL_STEER_TRANSDUCER_CORRELATION esPartialError A34 A45 Steering unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3010 ERR_SCREED_CTRL_POTI_WORK_UB_LINE_BREAK esPartialError A121 R100 Potentiometer, pressure screed work

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:6 - 3030
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 24 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3011 ERR_SCREED_CTRL_POTI_WORK_GND_LINE_BREAK esPartialError A121 R100 Potentiometer, pressure screed work

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:6 - 3030
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3012 ERR_SCREED_CTRL_POTI_STOP_UB_LINE_BREAK esPartialError A121 R101 Potentiometer, pressure screed stop

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:7 - 3032
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3013 ERR_SCREED_CTRL_POTI_STOP_GND_LINE_BREAK esPartialError A121 R101 Potentiometer, pressure screed stop

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:7 - 3032
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 25 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3014 ERR_SCREED_CTRL_POTI_TIME_LOCK_UB_LINE_BREAK esPartialError A121 R102 Potentiometer, time lock screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:8 - 3034
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3015 ERR_SCREED_CTRL_POTI_TIME_LOCK_GND_LINE_BREAK esPartialError A121 R102 Potentiometer, time lock screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:8 - 3034
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3016 ERR_SCREED_CTRL_LCS_POTI_BALANCE_LINE_BREAK_UB esPartialError A121 R123 Potentiometer, balance

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:9 - 3036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 26 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3017 ERR_SCREED_CTRL_LCS_POTI_BALANCE_LINE_BREAK_GND esPartialError A121 R123 Potentiometer, balance

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:9 - 3036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3020 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_LB esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3021 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_SHORT_UB esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 27 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3022 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_SHORT_GND esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3023 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_LB_FG esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3024 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_SHORT_UB_FG esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 28 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3025 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_SHORT_GND_FG esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3026 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_CONTROLLER1 esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3027 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B1_CONTROLLER2 esPartialError A121 Y230 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X68:43 - 3041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 29 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3030 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_LB esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3031 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_SHORT_UB esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3032 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_SHORT_GND esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 30 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3033 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_LB_FG esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3034 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_SHORT_UB_FG esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3035 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_SHORT_GND_FG esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 31 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3036 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_CONTROLLER1 esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3037 ERR_SCREED_CTRL_LCS_VALVE_PRESS_B2_CONTROLLER2 esPartialError A121 Y297 Solenoid valve, pressure load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X68:44 - 3045
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3040 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A1_LINE_BREAK esPartialError A121 Y226 Solenoid valve, screed up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:62 - 3053
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 32 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3041 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A1_SHORT_GND esPartialError A121 Y226 Solenoid valve, screed up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:62 - 3053
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3042 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A1_SHORT_UB esPartialError A121 Y226 Solenoid valve, screed up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:62 - 3053
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3043 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A2_LINE_BREAK esPartialError A121 Y227 Solenoid valve, floating position screed 1

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:20 - 3051
Causes Comment
C1 Bad connection in harness, connector or central electric Double L.C.S.: Y227, Y294
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 33 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3044 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A2_SHORT_GND esPartialError A121 Y227 Solenoid valve, floating position screed 1

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:20 - 3051
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3045 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A2_SHORT_UB esPartialError A121 Y227 Solenoid valve, floating position screed 1

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:20 - 3051
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3046 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A3_LINE_BREAK esPartialError A121 Y228 Solenoid valve, floating position screed 2

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:64 - 3052
Causes Comment
C1 Bad connection in harness, connector or central electric Double L.C.S.: Y227, Y295
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 34 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3047 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A3_SHORT_GND esPartialError A121 Y228 Solenoid valve, floating position screed 2

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:64 - 3052
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3048 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A3_SHORT_UB esPartialError A121 Y228 Solenoid valve, floating position screed 2

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:64 - 3052
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3049 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A4_2_3_LINE_BREAK esPartialError A121 Y229 Solenoid valve, activate load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:51 - 3053
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 35 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3050 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A4_2_3_SHORT_GND esPartialError A121 Y229 Solenoid valve, activate load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:51 - 3053
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3051 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A4_2_3_SHORT_UB esPartialError A121 Y229 Solenoid valve, activate load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:51 - 3053
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3052 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A8_2_6_LINE_BREAK esPartialError A121 Y296 Solenoid valve, activate load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:42 - 3054
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 36 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3053 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A8_2_6_SHORT_GND esPartialError A121 Y296 Solenoid valve, activate load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:42 - 3054
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3054 ERR_PROPEL_SCREED_CTRL_LCS_VALVE_A8_2_6_SHORT_UB esPartialError A121 Y296 Solenoid valve, activate load control system

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:42 - 3054
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3100 ERR_SCREED_EXT_VALVE_LEFT_OPEN_LINE_BREAK esPartialError A121 Y216 Solenoid valve, screed left open

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:2 - 3170
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 37 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3101 ERR_SCREED_EXT_VALVE_LEFT_OPEN_SHORT_GND esPartialError A121 Y216 Solenoid valve, screed left open

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:2 - 3170
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3102 ERR_SCREED_EXT_VALVE_LEFT_OPEN_SHORT_UB esEngineOff A121 Y216 Solenoid valve, screed left open

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:2 - 3170
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3103 ERR_SCREED_EXT_VALVE_LEFT_CLOSE_LINE_BREAK esPartialError A121 Y217 Solenoid valve, screed left close

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:3 - 3171
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 38 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3104 ERR_SCREED_EXT_VALVE_LEFT_CLOSE_SHORT_GND esPartialError A121 Y217 Solenoid valve, screed left close

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:3 - 3171
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3105 ERR_SCREED_EXT_VALVE_LEFT_CLOSE_SHORT_UB esEngineOff A121 Y217 Solenoid valve, screed left close

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:3 - 3171
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3106 ERR_SCREED_EXT_VALVE_RIGHT_OPEN_LINE_BREAK esPartialError A121 Y218 Solenoid valve, screed right open

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:24 - 3172
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 39 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3107 ERR_SCREED_EXT_VALVE_RIGHT_OPEN_SHORT_GND esPartialError A121 Y218 Solenoid valve, screed right open

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:24 - 3172
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3108 ERR_SCREED_EXT_VALVE_RIGHT_OPEN_SHORT_UB esEngineOff A121 Y218 Solenoid valve, screed right open

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:24 - 3172
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3109 ERR_SCREED_EXT_VALVE_RIGHT_CLOSE_LINE_BREAK esPartialError A121 Y219 Solenoid valve, screed right close

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:25 - 3173
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 40 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3110 ERR_SCREED_EXT_VALVE_RIGHT_CLOSE_SHORT_GND esPartialError A121 Y219 Solenoid valve, screed right close

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:25 - 3173
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3111 ERR_SCREED_EXT_VALVE_RIGHT_CLOSE_SHORT_UB esEngineOff A121 Y219 Solenoid valve, screed right close

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:25 - 3173
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3120 ERR_TAMPER_CTRL_PUMP_LB esPartialError A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 41 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3121 ERR_TAMPER_CTRL_PUMP_SHORT_UB esEngineOff A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3122 ERR_TAMPER_CTRL_PUMP_SHORT_GND esPartialError A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3123 ERR_TAMPER_CTRL_PUMP_LB_FG esPartialError A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 42 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3124 ERR_TAMPER_CTRL_PUMP_SHORT_UB_FG esEngineOff A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3125 ERR_TAMPER_CTRL_PUMP_SHORT_GND_FG esPartialError A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3126 ERR_TAMPER_CTRL_PUMP_CONTROLLER1 esEngineOff A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 43 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3127 ERR_TAMPER_CTRL_PUMP_CONTROLLER2 esEngineOff A121 Y224 Solenoid valve, tamper screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X68:22 - 3111
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3150 ERR_VIBRATION_CTRL_PUMP_LB esPartialError A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3151 ERR_VIBRATION_CTRL_PUMP_SHORT_UB esEngineOff A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 44 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3152 ERR_VIBRATION_CTRL_PUMP_SHORT_GND esPartialError A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3153 ERR_VIBRATION_CTRL_PUMP_LB_FG esPartialError A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3154 ERR_VIBRATION_CTRL_PUMP_SHORT_UB_FG esEngineOff A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 45 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3155 ERR_VIBRATION_CTRL_PUMP_SHORT_GND_FG esPartialError A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3156 ERR_VIBRATION_CTRL_PUMP_CONTROLLER1 esEngineOff A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3157 ERR_VIBRATION_CTRL_PUMP_CONTROLLER2 esEngineOff A121 Y225 Solenoid valve, vibrating plates screed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X68:21 - 3161
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 46 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3180 ERR_SCREED_LEVEL_VALVE_LEFT_UP_LINE_BREAK esPartialError A121 Y220 Solenoid valve, screed left up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:46 - 3196
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3181 ERR_SCREED_LEVEL_VALVE_LEFT_UP_SHORT_GND esPartialError A121 Y220 Solenoid valve, screed left up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:46 - 3196
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3182 ERR_SCREED_LEVEL_VALVE_LEFT_UP_SHORT_UB esEngineOff A121 Y220 Solenoid valve, screed left up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:46 - 3196
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 47 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3183 ERR_SCREED_LEVEL_VALVE_RIGHT_UP_LINE_BREAK esPartialError A121 Y222 Solenoid valve, screed right up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:48 - 3198
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3184 ERR_SCREED_LEVEL_VALVE_RIGHT_UP_SHORT_GND esPartialError A121 Y222 Solenoid valve, screed right up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:48 - 3198
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3185 ERR_SCREED_LEVEL_VALVE_RIGHT_UP_SHORT_UB esEngineOff A121 Y222 Solenoid valve, screed right up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:48 - 3198
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 48 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3186 ERR_SCREED_LEVEL_VALVE_LEFT_DOWN_LINE_BREAK esPartialError A121 Y221 Solenoid valve, screed left down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:47 - 3197
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3187 ERR_SCREED_LEVEL_VALVE_LEFT_DOWN_SHORT_GND esPartialError A121 Y221 Solenoid valve, screed left down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:47 - 3197
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3188 ERR_SCREED_LEVEL_VALVE_LEFT_DOWN_SHORT_UB esEngineOff A121 Y221 Solenoid valve, screed left down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:47 - 3197
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 49 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3189 ERR_SCREED_LEVEL_VALVE_RIGHT_DOWN_LINE_BREAK esPartialError A121 Y223 Solenoid valve, screed right down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X68:49 - 3199
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3190 ERR_SCREED_LEVEL_VALVE_RIGHT_DOWN_SHORT_GND esPartialError A121 Y223 Solenoid valve, screed right down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:49 - 3199
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3191 ERR_SCREED_LEVEL_VALVE_RIGHT_DOWN_SHORT_UB esEngineOff A121 Y223 Solenoid valve, screed right down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:49 - 3199
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 50 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3530 ERR_EE_BUSY_READ esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3531 ERR_EE_BUSY_WRITE esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3533 ERR_EE_SEG esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 51 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3534 ERR_EE_VERIFY esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3535 ERR_EE_MAX_READ_BYTES esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3536 ERR_EE_REDUNDANT_CHECK esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 52 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3537 ERR_EE_UNKOWN_RESULT esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3538 ERR_EE_SPI_COMM_FAULT esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3539 ERR_EE_RANGE esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 53 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3540 ERR_EE_READ esPartialError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3541 ERR_EE_LIFTIME_END esWarning A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3542 ERR_PARAM_READ_INDEX_DOES_NOT_MATCH esFatalError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 54 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3543 ERR_SET_LOCAL_ID_UNKNOWN_RESULT esFatalError A121 A121 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3630 ERR_VOLTAGE_HIGH_8_5_V_OUTPUT esFatalError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X68:23 __A121_8_5_V_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 55 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3631 ERR_VOLTAGE_LOW_8_5_V_OUTPUT esFatalError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:23 __A121_8_5_V_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3634 ERR_SUPPLY_VOLTAGE_WARNING esWarning A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:56 - X68:60 __A121_Supply_Voltage_Outputs -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3635 ERR_SUPPLY_VOLTAGE_SHUT_DOWN esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X68:56 - X68:60 __A121_Supply_Voltage_Outputs -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 56 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3644 ERR_CAN_BUSOFF_1 esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:26, X68:27 __A121_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3651 ERR_CAN_OBJ_3_RX_BUFF_OVERFLOW_1 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:26, X68:27 __A121_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3652 ERR_CAN_OBJ_4_RX_BUFF_OVERFLOW_1 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:26, X68:27 __A121_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 57 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3653 ERR_CAN_OBJ_5_RX_BUFF_OVERFLOW_1 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:26, X68:27 __A121_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3663 ERR_CAN_OBJ_15_RX_BUFF_OVERFLOW_1 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:26, X68:27 __A121_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3664 ERR_CAN_TX_BUFF_OVERFLOW_1 esWarning A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:26, X68:27 __A121_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 58 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3674 ERR_CAN_BUSOFF_2 esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3680 ERR_CAN_OBJ_2_RX_BUFF_OVERFLOW_2 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3681 ERR_CAN_OBJ_3_RX_BUFF_OVERFLOW_2 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 59 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3682 ERR_CAN_OBJ_4_RX_BUFF_OVERFLOW_2 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3683 ERR_CAN_OBJ_5_RX_BUFF_OVERFLOW_2 esFunctionInterference A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3684 ERR_CAN_TX_BUFF_OVERFLOW_2 esWarning A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 60 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3690 ERR_DXCHANGE_RX_INDEX_NOT_VALID esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3691 ERR_DXCHANGE_TX_INDEX_NOT_VALID esPartialError A121 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
3770 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_10_CO_2 esPartialError A121 A123 Module, data collector 2

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate X68:33, X68:53 __A121_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 61 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4010 ERR_HOPPER_WING_LEFT_VALVE_UP_LINE_BREAK esPartialError A122 Y203 Solenoid valve, hopper left up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:3 - 4180
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4011 ERR_HOPPER_WING_LEFT_VALVE_UP_SHORT_GND esPartialError A122 Y203 Solenoid valve, hopper left up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:3 - 4180
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4012 ERR_HOPPER_WING_LEFT_VALVE_UP_SHORT_UB esEngineOff A122 Y203 Solenoid valve, hopper left up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:3 - 4180
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 62 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4013 ERR_HOPPER_WING_RIGHT_VALVE_UP_LINE_BREAK esPartialError A122 Y205 Solenoid valve, hopper right up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:25 - 4182
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4014 ERR_HOPPER_WING_RIGHT_VALVE_UP_SHORT_GND esPartialError A122 Y205 Solenoid valve, hopper right up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:25 - 4182
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4015 ERR_HOPPER_WING_RIGHT_VALVE_UP_SHORT_UB esEngineOff A122 Y205 Solenoid valve, hopper right up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:25 - 4182
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 63 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4016 ERR_HOPPER_WING_LEFT_VALVE_DOWN_LINE_BREAK esPartialError A122 Y202 Solenoid valve, hopper left down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:2 - 4181
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4017 ERR_HOPPER_WING_LEFT_VALVE_DOWN_SHORT_GND esPartialError A122 Y202

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:2 - 4181
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4018 ERR_HOPPER_WING_LEFT_VALVE_DOWN_SHORT_UB esEngineOff A122 Y202 Solenoid valve, hopper left down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:2 - 4181
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 64 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4019 ERR_HOPPER_WING_RIGHT_VALVE_DOWN_LINE_BREAK esPartialError A122 Y204 Solenoid valve, hopper right down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:24 - 4183
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4020 ERR_HOPPER_WING_RIGHT_VALVE_DOWN_SHORT_GND esPartialError A122 Y204 Solenoid valve, hopper right down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:24 - 4183
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4021 ERR_HOPPER_WING_RIGHT_VALVE_DOWN_SHORT_UB esEngineOff A122 Y204 Solenoid valve, hopper right down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:24 - 4183
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 65 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4022 ERR_HOPPER_FLAP_VALVE_UP_LINE_BREAK esPartialError A122 Y287 Solenoid valve, flap up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:44 - 4184
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4023 ERR_HOPPER_FLAP_VALVE_UP_SHORT_GND esPartialError A122 Y287 Solenoid valve, flap up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:44 - 4184
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4024 ERR_HOPPER_FLAP_VALVE_UP_SHORT_UB esEngineOff A122 Y287 Solenoid valve, flap up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:44 - 4184
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 66 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4025 ERR_HOPPER_FLAP_VALVE_DOWN_LINE_BREAK esPartialError A122 Y288 Solenoid valve, flap down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:64 - 4185
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4026 ERR_HOPPER_FLAP_VALVE_DOWN_SHORT_GND esPartialError A122 Y288 Solenoid valve, flap down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:64 - 4185
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4027 ERR_HOPPER_FLAP_VALVE_DOWN_SHORT_UB esEngineOff A122 Y288 Solenoid valve, flap down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:64 - 4185
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 67 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4050 ERR_SUPPLY_FEEDER_RELAY_LINE_BREAK esPartialError A122 K163 Relay, load

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:22 - 4009
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4051 ERR_SUPPLY_FEEDER_RELAY_SHORT_GND esPartialError A122 K163 Relay, load

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:22 - 4009
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4052 ERR_SUPPLY_FEEDER_RELAY_SHORT_UB esPartialError A122 K163 Relay, load

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:22 - 4009
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 68 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4100 ERR_AUGER_POTI_LEFT_UB_LINE_BREAK esFunctionInterference A122 R98 Potentiometer, adjustment load auger left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:8 - 4010
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4101 ERR_AUGER_POTI_LEFT_GND_LINE_BREAK esFunctionInterference A122 R98 Potentiometer, adjustment load auger left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:8 - 4010
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4102 ERR_AUGER_POTI_RIGHT_UB_LINE_BREAK esFunctionInterference A122 R99 Potentiometer, adjustment load auger right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:9 - 4011
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 69 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4103 ERR_AUGER_POTI_RIGHT_GND_LINE_BREAK esFunctionInterference A122 R99 Potentiometer, adjustment load auger right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:9 - 4011
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4104 ERR_AUGER_BOX_VALVE_UP_LINE_BREAK esPartialError A122 Y214 Solenoid valve, auger box up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:50 - 4090
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4105 ERR_AUGER_BOX_VALVE_UP_SHORT_GND esPartialError A122 Y214 Solenoid valve, auger box up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:50 - 4090
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 70 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4106 ERR_AUGER_BOX_VALVE_UP_SHORT_UB esEngineOff A122 Y214 Solenoid valve, auger box up

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:50 - 4090
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4107 ERR_AUGER_BOX_VALVE_DOWN_LINE_BREAK esPartialError A122 Y215 Solenoid valve, auger box down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:51 - 4091
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4108 ERR_AUGER_BOX_VALVE_DOWN_SHORT_GND esPartialError A122 Y215 Solenoid valve, auger box down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:51 - 4091
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 71 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4109 ERR_AUGER_BOX_VALVE_DOWN_SHORT_UB esEngineOff A122 Y215 Solenoid valve, auger box down

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect X69:51 - 4091
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4110 ERR_AUGER_PUMP_LEFT_FORWARD_LB esPartialError A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4111 ERR_AUGER_PUMP_LEFT_FORWARD_SHORT_UB esEngineOff A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 72 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4112 ERR_AUGER_PUMP_LEFT_FORWARD_SHORT_GND esPartialError A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4113 ERR_AUGER_PUMP_LEFT_FORWARD_LB_FG esPartialError A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4114 ERR_AUGER_PUMP_LEFT_FORWARD_SHORT_UB_FG esEngineOff A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 73 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4115 ERR_AUGER_PUMP_LEFT_FORWARD_SHORT_GND_FG esPartialError A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4116 ERR_AUGER_PUMP_LEFT_FORWARD_CONTROLLER1 esFunctionInterference A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4117 ERR_AUGER_PUMP_LEFT_FORWARD_CONTROLLER2 esFunctionInterference A122 Y210 Solenoid valve, auger left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:46 - 4031
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 74 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4120 ERR_AUGER_PUMP_LEFT_BACKWARD_LB esPartialError A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4121 ERR_AUGER_PUMP_LEFT_BACKWARD_SHORT_UB esEngineOff A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4122 ERR_AUGER_PUMP_LEFT_BACKWARD_SHORT_GND esPartialError A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 75 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4123 ERR_AUGER_PUMP_LEFT_BACKWARD_LB_FG esPartialError A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4124 ERR_AUGER_PUMP_LEFT_BACKWARD_SHORT_UB_FG esEngineOff A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4125 ERR_AUGER_PUMP_LEFT_BACKWARD_SHORT_GND_FG esPartialError A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 76 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4126 ERR_AUGER_PUMP_LEFT_BACKWARD_CONTROLLER1 esFunctionInterference A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4127 ERR_AUGER_PUMP_LEFT_BACKWARD_CONTROLLER2 esFunctionInterference A122 Y211 Solenoid valve, auger left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:47 - 4036
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4130 ERR_AUGER_PUMP_RIGHT_FORWARD_LB esPartialError A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 77 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4131 ERR_AUGER_PUMP_RIGHT_FORWARD_SHORT_UB esEngineOff A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4132 ERR_AUGER_PUMP_RIGHT_FORWARD_SHORT_GND esPartialError A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4133 ERR_AUGER_PUMP_RIGHT_FORWARD_LB_FG esPartialError A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 78 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4134 ERR_AUGER_PUMP_RIGHT_FORWARD_SHORT_UB_FG esEngineOff A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4135 ERR_AUGER_PUMP_RIGHT_FORWARD_SHORT_GND_FG esPartialError A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4136 ERR_AUGER_PUMP_RIGHT_FORWARD_CONTROLLER1 esFunctionInterference A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 79 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4137 ERR_AUGER_PUMP_RIGHT_FORWARD_CONTROLLER2 esFunctionInterference A122 Y212 Solenoid valve, auger right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:48 - 4041
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4140 ERR_AUGER_PUMP_RIGHT_BACKWARD_LB esPartialError A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4141 ERR_AUGER_PUMP_RIGHT_BACKWARD_SHORT_UB esEngineOff A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 80 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4142 ERR_AUGER_PUMP_RIGHT_BACKWARD_SHORT_GND esPartialError A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4143 ERR_AUGER_PUMP_RIGHT_BACKWARD_LB_FG esPartialError A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4144 ERR_AUGER_PUMP_RIGHT_BACKWARD_SHORT_UB_FG esEngineOff A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 81 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4145 ERR_AUGER_PUMP_RIGHT_BACKWARD_SHORT_GND_FG esPartialError A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4146 ERR_AUGER_PUMP_RIGHT_BACKWARD_CONTROLLER1 esFunctionInterference A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4147 ERR_AUGER_PUMP_RIGHT_BACKWARD_CONTROLLER2 esFunctionInterference A122 Y213 Solenoid valve, auger right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:49 - 4046
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 82 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4150 ERR_AUGER_SONIC_SENSOR_LEFT_LB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:18, X25:D __Auger_Sonic_Sensor_Left 4020
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4151 ERR_AUGER_SONIC_SENSOR_LEFT_SHORT_UB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:18, X25:D __Auger_Sonic_Sensor_Left 4020
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4152 ERR_AUGER_SONIC_SENSOR_LEFT_SHORT_GND esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:18, X25:D __Auger_Sonic_Sensor_Left 4020
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 83 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4154 ERR_AUGER_SONIC_SENSOR_LEFT_INTERNAL esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component X69:18, X25:D __Auger_Sonic_Sensor_Left 4020
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4155 ERR_AUGER_XDUCER_LEFT_LINE_BREAK esFunctionInterference A122 R98 Potentiometer, adjustment load auger left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:8 - 4010
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4156 ERR_AUGER_XDUCER_LEFT_CURRENT_TOO_HIGH esFunctionInterference A122 R98 Potentiometer, adjustment load auger left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:8 - 4010
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 84 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4157 ERR_AUGER_XDUCER_RIGHT_LINE_BREAK esFunctionInterference A122 R99 Potentiometer, adjustment load auger right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:9 - 4011
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4158 ERR_AUGER_XDUCER_RIGHT_CURRENT_TOO_HIGH esFunctionInterference A122 R99 Potentiometer, adjustment load auger right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:9 - 4011
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4160 ERR_AUGER_SONIC_SENSOR_RIGHT_LB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:19, X26:D __Auger_Sonic_Sensor_Right 4022
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 85 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4161 ERR_AUGER_SONIC_SENSOR_RIGHT_SHORT_UB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:19, X26:D __Auger_Sonic_Sensor_Right 4022
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4162 ERR_AUGER_SONIC_SENSOR_RIGHT_SHORT_GND esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:19, X26:D __Auger_Sonic_Sensor_Right 4022
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4164 ERR_AUGER_SONIC_SENSOR_RIGHT_INTERNAL esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component X69:19, X26:D __Auger_Sonic_Sensor_Right 4022
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 86 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4165 ERR_CONVEYOR_POTI_LEFT_LINE_BREAK_UB esFunctionInterference A122 R96 Potentiometer, adjustment load conveyor left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:6 - 4100
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4166 ERR_CONVEYOR_POTI_LEFT_LINE_BREAK_GND esFunctionInterference A122 R96 Potentiometer, adjustment load conveyor left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:6 - 4100
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4167 ERR_CONVEYOR_POTI_RIGHT_LINE_BREAK_UB esFunctionInterference A122 R97 Potentiometer, adjustment load conveyor right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:7 - 4101
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 87 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4168 ERR_CONVEYOR_POTI_RIGHT_LINE_BREAK_GND esFunctionInterference A122 R97 Potentiometer, adjustment load conveyor right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:7 - 4101
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4169 ERR_CONVEYOR_PUMP_LEFT_FORWARD_LB esPartialError A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4170 ERR_CONVEYOR_PUMP_LEFT_FORWARD_SHORT_UB esEngineOff A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 88 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4171 ERR_CONVEYOR_PUMP_LEFT_FORWARD_SHORT_GND esPartialError A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4172 ERR_CONVEYOR_PUMP_LEFT_FORWARD_LB_FG esPartialError A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4173 ERR_CONVEYOR_PUMP_LEFT_FORWARD_SHORT_UB_FG esEngineOff A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 89 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4174 ERR_CONVEYOR_PUMP_LEFT_FORWARD_SHORT_GND_FG esPartialError A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4175 ERR_CONVEYOR_PUMP_LEFT_FORWARD_CONTROLLER1 esEngineOff A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4176 ERR_CONVEYOR_PUMP_LEFT_FORWARD_CONTROLLER2 esEngineOff A122 Y207 Solenoid valve, conveyor left forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:20 - 4121
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 90 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4179 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_LB esPartialError A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4180 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_SHORT_UB esEngineOff A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4181 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_SHORT_GND esPartialError A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 91 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4182 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_LB_FG esPartialError A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4183 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_SHORT_UB_FG esEngineOff A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4184 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_SHORT_GND_FG esPartialError A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 92 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4185 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_CONTROLLER1 esEngineOff A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4186 ERR_CONVEYOR_PUMP_LEFT_BACKWARD_CONTROLLER2 esEngineOff A122 Y206 Solenoid valve, conveyor left reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:21 - 4126
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4189 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_LB esPartialError A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 93 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4190 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_SHORT_UB esEngineOff A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4191 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_SHORT_GND esPartialError A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4192 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_LB_FG esPartialError A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 94 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4193 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_SHORT_UB_FG esEngineOff A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4194 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_SHORT_GND_FG esPartialError A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4195 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_CONTROLLER1 esEngineOff A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 95 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4196 ERR_CONVEYOR_PUMP_RIGHT_FORWARD_CONTROLLER2 esEngineOff A122 Y209 Soleonid valve, conveyor right forward

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:42 - 4131
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4199 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_LB esPartialError A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4200 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_SHORT_UB esEngineOff A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 96 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4201 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_SHORT_GND esPartialError A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4202 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_LB_FG esPartialError A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4203 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_SHORT_UB_FG esEngineOff A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 97 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4204 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_SHORT_GND_FG esPartialError A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4205 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_CONTROLLER1 esEngineOff A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4206 ERR_CONVEYOR_PUMP_RIGHT_BACKWARD_CONTROLLER2 esEngineOff A122 Y208 Solenoid valve, conveyor right reverse

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:43 - 4136
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 98 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4209 ERR_CONVEYOR_SONIC_SENSOR_LEFT_LB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:34, X29:D __Conveyor_Sonic_Sensor_Left 4110
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4210 ERR_CONVEYOR_SONIC_SENSOR_LEFT_SHORT_UB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:34, X29:D __Conveyor_Sonic_Sensor_Left 4110
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4211 ERR_CONVEYOR_SONIC_SENSOR_LEFT_SHORT_GND esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:34, X29:D __Conveyor_Sonic_Sensor_Left 4110
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 99 of 203
BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4213 ERR_CONVEYOR_SONIC_SENSOR_LEFT_INTERNAL esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component X69:34, X29:D __Conveyor_Sonic_Sensor_Left 4110
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4214 ERR_CONVEYOR_SONIC_SENSOR_RIGHT_LB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:35, X30:D __Conveyor_Sonic_Sensor_Right 4112
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4215 ERR_CONVEYOR_SONIC_SENSOR_RIGHT_SHORT_UB esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:35, X30:D __Conveyor_Sonic_Sensor_Right 4112
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 100 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4216 ERR_CONVEYOR_SONIC_SENSOR_RIGHT_SHORT_GND esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:35, X30:D __Conveyor_Sonic_Sensor_Right 4112
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4218 ERR_CONVEYOR_SONIC_SENSOR_RIGHT_INTERNAL esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component X69:35, X30:D __Conveyor_Sonic_Sensor_Right 4112
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4220 ERR_CONVEYOR_XDUCER_LEFT_LINE_BREAK esFunctionInterference A122 R96 Potentiometer, adjustment load conveyor left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:6 - 4100
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 101 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4221 ERR_CONVEYOR_XDUCER_LEFT_CURRENT_TOO_HIGH esFunctionInterference A122 R96 Potentiometer, adjustment load conveyor left

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:6 - 4100
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4222 ERR_CONVEYOR_XDUCER_RIGHT_LINE_BREAK esFunctionInterference A122 R97 Potentiometer, adjustment load conveyor right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X69:7 - 4101
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4223 ERR_CONVEYOR_XDUCER_RIGHT_CURRENT_TOO_HIGH esFunctionInterference A122 R97 Potentiometer, adjustment load conveyor right

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X69:7 - 4101
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 102 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4530 ERR_EE_BUSY_READ esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4531 ERR_EE_BUSY_WRITE esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4533 ERR_EE_SEG esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 103 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4534 ERR_EE_VERIFY esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4535 ERR_EE_MAX_READ_BYTES esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4536 ERR_EE_REDUNDANT_CHECK esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 104 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4537 ERR_EE_UNKOWN_RESULT esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4538 ERR_EE_SPI_COMM_FAULT esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4539 ERR_EE_RANGE esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 105 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4540 ERR_EE_READ esPartialError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4541 ERR_EE_LIFTIME_END esWarning A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4542 ERR_PARAM_READ_INDEX_DOES_NOT_MATCH esFatalError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 106 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4543 ERR_SET_LOCAL_ID_UNKNOWN_RESULT esFatalError A122 A122 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4630 ERR_VOLTAGE_HIGH_8_5_V_OUTPUT esFatalError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X69:23 __A122_8_5_V_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4631 ERR_VOLTAGE_LOW_8_5_V_OUTPUT esFatalError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:23 __A122_8_5_V_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 107 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4634 ERR_SUPPLY_VOLTAGE_WARNING esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:56 - X69:60 __A122_Supply_Voltage_Outputs -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4635 ERR_SUPPLY_VOLTAGE_SHUT_DOWN esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X69:56 - X69:60 __A122_Supply_Voltage_Outputs -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4644 ERR_CAN_BUSOFF_1 esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 108 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4650 ERR_CAN_OBJ_2_RX_BUFF_OVERFLOW_1 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4651 ERR_CAN_OBJ_3_RX_BUFF_OVERFLOW_1 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4652 ERR_CAN_OBJ_4_RX_BUFF_OVERFLOW_1 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 109 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4653 ERR_CAN_OBJ_5_RX_BUFF_OVERFLOW_1 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4663 ERR_CAN_OBJ_15_RX_BUFF_OVERFLOW_1 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4664 ERR_CAN_TX_BUFF_OVERFLOW_1 esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:26, X69:27 __A122_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 110 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4674 ERR_CAN_BUSOFF_2 esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4680 ERR_CAN_OBJ_2_RX_BUFF_OVERFLOW_2 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4681 ERR_CAN_OBJ_3_RX_BUFF_OVERFLOW_2 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 111 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4682 ERR_CAN_OBJ_4_RX_BUFF_OVERFLOW_2 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4683 ERR_CAN_OBJ_5_RX_BUFF_OVERFLOW_2 esFunctionInterference A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4684 ERR_CAN_TX_BUFF_OVERFLOW_2 esWarning A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 112 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4690 ERR_DXCHANGE_RX_INDEX_NOT_VALID esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4691 ERR_DXCHANGE_TX_INDEX_NOT_VALID esPartialError A122 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4770 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_10_CO_2 esPartialError A122 A123 Module, data collector 2

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Fault ocurs also in case the SCU (A121) did not start the module.
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 113 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
4774 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_14_CO_2 esPartialError A122 A145 CAN I/O module

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate X69:33, X69:53 __A122_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Fault ocurs also in case the MCU (A122) did not start the module.
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5010 ERR_ENGINE_RELAY_SHUTDOWN_UB esFunctionInterference A34 K22 Relay, shut off solenoid engine

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:2 - 5003
Causes Comment
C1 Bad connection in harness, connector or central electric 510
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5011 ERR_ENGINE_RELAY_SHUTDOWN_GND esFunctionInterference A34 K22 Relay, shut off solenoid engine

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:2 - 5003
Causes Comment
C1 Bad connection in harness, connector or central electric 511
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 114 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5012 ERR_ENGINE_RELAY_SHUTDOWN_LINE_BREAK esFunctionInterference A34 K22 Relay, shut off solenoid engine

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:2 - 5003
Causes Comment
C1 Bad connection in harness, connector or central electric 512
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5018 ERR_ENIGNE_MD_PLUS_RUN esWarning A34 G02 Generator

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X70:7 - 5024
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5024 ERR_ENGINE_COOL_WATER_LEVEL_WARNING esWarningHorn A34 B55 Floating switch, coolant expansion tank

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level X70:8 - 5021
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 -

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 115 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5025 ERR_ENGINE_COOL_WATER_LEVEL_SHUT_DOWN esEngineOff A34 B55 Floating switch, coolant expansion tank

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level X70:8 - 5021
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5026 ERR_ENGINE_AIR_FILTER_WARNING esWarning A34 B03 Maintenance switch, air cleaner

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level X70:6 - 5025
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 -

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5100 ERR_ENGINE_EEC_WARNING_LAMP esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 116 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5101 ERR_ENGINE_EEC_RED_STOP_LAMP esFunctionInterference A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5102 ERR_ENGINE_EEC_ERROR_NO esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - Electronic engine control (A48) has 1 ore more errors pending
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5110 ERR_ENGINE_EEC_ACCELERATOR_PEDAL_POSITION_1 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 117 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5111 ERR_ENGINE_EEC_OIL_LEVEL esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Lower limit for measure exceeded Check oil level.
C2 -
C3 -

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5112 ERR_ENGINE_EEC_OIL_PRESSURE esWarningHorn A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5113 ERR_ENGINE_EEC_INTAKE_MANIFOLD_1_PRESSURE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 118 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5114 ERR_ENGINE_EEC_INTAKE_MANIFOLD_TEMPERATURE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level - - -
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5115 ERR_ENGINE_EEC_BAROMETRIC_PRESSURE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level - - -
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 -

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5116 ERR_ENGINE_EEC_COOLANT_TEMPERATURE esWarningHorn A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level - - -
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 119 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5117 ERR_ENGINE_EEC_FUEL_TEMPERATURE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level - - -
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 -

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5118 ERR_ENGINE_EEC_ENGINE_SPEED esWarning A34 A48 Electronical engine controller
,
BFMI # BFMI Text Terminal Signal Display Code for Diagnosis
2 Data erratic, intermittent or incorrect - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5119 ERR_ENGINE_EEC_WATER_IN_FUEL esWarning A34 B124 Sensor, water trap fuel

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level X3:3, X3:4 - -
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 120 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5120 ERR_ENGINE_EEC_CAN_COMMUNICATION esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5122 ERR_ENGINE_EEC_TSC1 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5123 ERR_ENGINE_EEC_BAM_RECEIVE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 121 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5124 ERR_ENGINE_EEC_BAM_RECEIVE_2 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5126 ERR_ENGINE_EEC_CAN_COMMUNICATION_1 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5127 ERR_ENGINE_EEC_COOLANT_LEVEL esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 122 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5128 ERR_ENGINE_EEC_RAIL_PRESSURE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 0
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5129 ERR_ENGINE_EEC_EEPROM_MEMORY_ACCESS esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5130 ERR_ENGINE_EEC_OIL_PRESSURE_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 123 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5131 ERR_ENGINE_EEC_INTAKE_MANIFOLD_1_PRESSURE_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5132 ERR_ENGINE_EEC_INTAKE_MANIFOLD_1_TEMP_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5133 ERR_ENGINE_EEC_COOLANT_TEMPERATURE_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 124 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5134 ERR_ENGINE_EEC_ENGINE_SPEED_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5135 ERR_ENGINE_EEC_WATER_IN_FUEL_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5136 ERR_ENGINE_EEC_FUEL_DELIVERY_PRESSURE_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 125 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5137 ERR_ENGINE_EEC_COOLANT_LEVEL_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5138 ERR_ENGINE_EEC_RAIL_PRESSURE_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5139 ERR_ENGINE_EEC_FUEL_PUMP esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 126 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5140 ERR_ENGINE_EEC_UNKNOWN_ERROR_ENGINE_1 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - DEUTZ: EMR, MTU: CPC
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5141 ERR_ENGINE_EEC_BAROMETRIC_PRESSURE_SENSOR esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5144 ERR_ENGINE_EEC_FUEL_DELIVERY_PRESSURE esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 127 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5145 ERR_ENGINE_EEC_UNKNOWN_ERROR_ENGINE_2 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - MTU: ACM; Check AdBlue level.
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5146 ERR_ENGINE_EEC_UNKNOWN_ERROR_EXHAUST_EMISSION_CONTROLLER esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - MTU: ACM; Check AdBlue level.
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5166 ERR_ENGINE_EEC_KEY_SWITCH_BATTERY_POTENTIAL_ENGINE_1 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - MTU: CPC; Check fuse F95
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 128 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5167 ERR_ENGINE_EEC_KEY_SWITCH_BATTERY_POTENTIAL_ENGINE_2 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - MTU: MCM; Check fuse F95
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5168 ERR_ENGINE_EEC_BATTERY_POTENTIAL esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5200 ERR_EMC_DPF_WAS_NOT_REGENERATED_RPM_LIM esWarningHorn A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - DEUTZ TCD 6.1 TIER 4i
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 129 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5201 ERR_EMC_DPF_REGEN_POWER_REDUCTION_PHASE1 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - DEUTZ TCD 6.1 TIER 4i
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5202 ERR_EMC_DPF_REGEN_POWER_REDUCTION_PHASE2 esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - DEUTZ TCD 6.1 TIER 4i
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5205 ERR_ENGINE_POWER_REDUCTION_LOW_LAMBDA esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 130 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5211 ERR_ENGINE_EEC_INDUCEMENT_CHANGE esWarningHorn A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5220 ERR_ENGINE_EEC_AFTERTREAT_1_SCR_CAT_CONVERSION_EFFICIENCY esFunctionInterference A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - MTU OM934 TIER 4f
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5221 ERR_ENGINE_EEC_FINAL_INDUCEMENT esWarning A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 131 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5300 ERR_ENG_PHERIPHERAL_FUEL_LEVEL_SENSOR_LB esWarning A34 R03 Sensor, fuel gauge

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X71:2 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5301 ERR_ENG_PHERIPHERAL_FUEL_LEVEL_SENSOR_GND esWarning A34 R03 Sensor, fuel gauge

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X71:2 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5302 ERR_ENG_PHERIPHERAL_SPEED_SWITCHES_PLAUSIBILITY esWarning A34 S120 Switch, engine speed

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect X35:38, X35:39 - 5002
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 132 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5400 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_LB esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5401 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_SHORT_UB esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5402 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_SHORT_GND esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 133 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5403 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_LB_FG esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5404 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_SHORT_UB_FG esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5405 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_SHORT_GND_FG esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 134 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5406 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_CONTROLLER1 esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5407 ERR_FAN_DRIVE_VALVE_SPEED_CONTROL_CONTROLLER2 esWarningHorn A34 Y286 Solenoid valve, fan

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit X35:64 - 5415
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5410 ERR_FAN_DRIVE_AMBIENT_TEMP_SENSOR_LB esWarningHorn A34 B218 Temperature sensor, ambient temperature

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X73:3, X73:10 - 5413
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 135 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5411 ERR_FAN_DRIVE_AMBIENT_TEMP_SENSOR_OUT_OF_RANGE esWarningHorn A34 B218 Temperature sensor, ambient temperature

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level X73:3, X73:10 - 5413
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5412 ERR_FAN_DRIVE_AMBIENT_TEMP_SENSOR_INVALID esWarningHorn A34 B218 Temperature sensor, ambient temperature

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect X73:3, X73:10 - 5413
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 Correct / check setting
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5500 ERR_HYDR_FILTER_CHARGE_WARNING esWarningHorn A34 B21 Differential pressure switch, hydraulic oil filter

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level X70:3 - 5501
Causes Comment
C1 Upper limit for measure exceeded B22, B121, B122 connected in parallel
C2 -
C3 -

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 136 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5502 ERR_HYDR_FILTER_WARNING esWarningHorn A34 B42 Differential pressure switch, hydraulic oil filter

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level X70:2 - 5500
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 -

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5504 ERR_HYDR_OIL_TEMP_WARNING esWarningHorn A34 B98 Temperature sensor, hydraulic oil temperature

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level X71:3, X71:10 - 5412
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5506 ERR_HYDR_OIL_LEVEL_WARNING esWarningHorn A34 B23 Float switch, hydraulic oil

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level X70:5 - 5506
Causes Comment
C1 Lower limit for measure exceeded -
C2 -
C3 Faulty actuator or input/ sensor device

Solutions
S1 Ensure conditions to overcome the threshold value
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 137 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5508 ERR_HYDR_DIRT_WARNING esWarningHorn A34 B19 Magnetic sensor, contamination

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level X70:11 - 5508
Causes Comment
C1 Upper limit for measure exceeded -
C2 -
C3 -

Solutions
S1 Ensure conditions to fall below the threshold value
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5512 ERR_HYDR_OIL_TEMP_SENSOR esWarningHorn A34 B98 Temperature sensor, hydraulic oil temperature

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X71:3, X71:10 - 5412
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 138 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5520 ERR_HYDR_VALVE_SERVICE_LINE_BREAK esPartialError A34 Y194 Soleonid valve, activation hydraulic

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:24 - 5520
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5521 ERR_HYDR_VALVE_SERVICE_SHORT_GND esPartialError A34 Y194 Soleonid valve, activation hydraulic

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:24 - 5520
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5522 ERR_HYDR_VALVE_SERVICE_SHORT_UB esPartialError A34 Y194 Soleonid valve, activation hydraulic

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:24 - 5520
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 139 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5530 ERR_HYDR_VALVE_CHARGE_BYPASS_LINE_BREAK esFunctionInterference A34 Y404 Solenoid valve, bypass

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:50 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5531 ERR_HYDR_VALVE_CHARGE_BYPASS_SHORT_GND esPartialError A34 Y404 Solenoid valve, bypass

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:50 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5532 ERR_HYDR_VALVE_CHARGE_BYPASS_SHORT_UB esEngineOff A34 Y404 Solenoid valve, bypass

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:50 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 140 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5601 ERR_POWER_SYNC_OUTPUT_SHORT_UB esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:11 __A34_PowerSnyc_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
5602 ERR_POWER_SYNC_OUTPUT_SHORT_GND esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6200 ERR_ENGINE_EEC_EGR_VALVE_POSITION_TO_HIGH esWarning A34 A44 MCM, SPN: 27

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


10 Abnormal rate of change - - -
Causes Comment
C1 MCM error MDEG/HDEP: MU ist set if EGR valve position deveation is to high MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 141 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6201 ERR_ENGINE_EEC_ENG_SPEED_SNA_VIA_CAN esWarning A34 A140 ACM, SPN: 190

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Engine Speed Signal Not Available Via CAN MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6202 ERR_ENGINE_EEC_ACT_TORQUE_SNA_VIA_CAN esWarning A34 A140 ACM, SPN: 513

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Actual Torque Signal Not Available Via CAN MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6203 ERR_ENGINE_EEC_LOST_COMM_WITH_ENGINE esWarning A34 A140 ACM, SPN: 625

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Lost Communication With Engine CAN MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 142 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6204 ERR_ENGINE_EEC_LOST_COMM_WITH_AFTERTREAT_1 esWarning A34 A44 MCM, SPN: 1231

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 MCM error MDEG/HDEP: ACM Message Not Received or has Stopped Arriving MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6205 ERR_ENGINE_EEC_SCR_CAT_UREA_TANK_LEVEL_CIRC_LOW esWarning A34 A140 ACM, SPN: 1761

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Reductant Level Sensor "A" Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6206 ERR_ENGINE_EEC_SCR_CAT_UREA_TANK_LEVEL_CIRC_HIGH esWarning A34 A140 ACM, SPN: 1761

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Reductant Level Sensor "A" Circuit High MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 143 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6207 ERR_ENGINE_EEC_SCR_CAT_UREA_TANK_LEVEL_NO_CAN esWarning A34 A140 ACM, SPN: 1761

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Urea Tank and Level Sensor Missing CAN Signal MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -
Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6208 ERR_ENGINE_EEC_SCR_CAT_UREA_TEMPERATURE_CIRC_LOW esWarning A34 A140 ACM, SPN: 3031

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Reductant Tank Temperature Sensor Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6209 ERR_ENGINE_EEC_SCR_CAT_UREA_TEMPERATURE_CIRC_HIGH esWarning A34 A140 ACM, SPN: 3031

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Reductant Tank Temperature Sensor Circuit High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 144 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6210 ERR_ENGINE_EEC_SCR_CAT_UREA_TEMPERATURE_NO_CAN esWarning A34 A140 ACM, SPN: 3031

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 MU_ISP_CAN_T_UREA_TANK_ERR MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6211 ERR_ENGINE_EEC_INTAKE_NOX_SENSOR_RANGE esWarning A34 A140 ACM, SPN: 3216

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


7 Mechanical system not responding or or out of adjustment - - -
Causes Comment
C1 NOx Sensor Circuit Range/Performance Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with min 20% torque, speed > 1000 rpm, for 5min after melting point release
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6212 ERR_ENGINE_EEC_INTAKE_NOX_SENSOR_NO_COMM esWarning A34 A140 ACM, SPN: 3216

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


13 Out of calibration - - -
Causes Comment
C1 Lost Communication With NOX Sensor "A" MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 145 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6213 ERR_ENGINE_EEC_INTAKE_NOX_SENSOR_CIRC_LOW esWarning A34 A140 ACM, SPN: 3216

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 NOx Sensor Circuit Low Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine running, Nox melting point release for 180s (Melting point release depending on temperature and load, ca. 10min engine running necessaray)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6214 ERR_ENGINE_EEC_INTAKE_NOX_SENSOR_CIRC_HIGH esWarning A34 A140 ACM, SPN: 3216

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 NOx Sensor Circuit High Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine running, Nox melting point release for 180s (Melting point release depending on temperature and load, ca. 10min engine running necessaray)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6215 ERR_ENGINE_EEC_OUTLET_NOX_SENSOR_RANGE esWarning A34 A140 ACM, SPN: 3226

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


7 Mechanical system not responding or or out of adjustment - - -
Causes Comment
C1 NOx Sensor Circuit Range/Performance Bank 1 Sensor 2 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with min 20% torque, speed > 1000 rpm, for 5min after melting point release
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 146 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6216 ERR_ENGINE_EEC_OUTLET_NOX_SENSOR_NO_COMM esWarning A34 A140 ACM, SPN: 3226

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


13 Out of calibration - - -
Causes Comment
C1 Lost Communication With NOX Sensor "B" MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6217 ERR_ENGINE_EEC_OUTLET_NOX_SENSOR_CIRC_LOW esWarning A34 A140 ACM, SPN: 3226

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 NOx Sensor Circuit Low Bank 1 Sensor 2 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine running, Nox melting point release for 180s (Melting point release depending on temperature and load, ca. 25min engine running necessaray)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6218 ERR_ENGINE_EEC_OUTLET_NOX_SENSOR_CIRC_HIGH esWarning A34 A140 ACM, SPN: 3226

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 NOx Sensor Circuit High Bank 1 Sensor 2 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine running, Nox melting point release for 180s (Melting point release depending on temperature and load, ca. 25min engine running necessaray)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 147 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6219 ERR_ENGINE_EEC_EXHAUST_GAS_MASS_FLOW esWarning A34 A140 ACM, SPN: 3236

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Exhaust Mass Signal Not Available via CAN MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6220 ERR_ENGINE_EEC_DPF_IN_GAS_TEMP_CIRC_LOW esWarning A34 A140 ACM, SPN: 3246

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit Low Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6221 ERR_ENGINE_EEC_DPF_IN_GAS_TEMP_CIRC_HIGH esWarning A34 A140 ACM, SPN: 3246

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit High Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 148 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6222 ERR_ENGINE_EEC_DIESEL_EX_FLUID_DOSING_UNIT_CIRC_LOW esWarning A34 A140 ACM, SPN: 3361

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Reductant Injection Valve Circuit Low Bank 1 Unit 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6223 ERR_ENGINE_EEC_DIESEL_EX_FLUID_DOSING_UNIT_CIRC_HIGH esWarning A34 A140 ACM, SPN: 3361

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Reductant Injection Valve Circuit High Bank 1 Unit 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Dosage necessaray, full load with 50% torque and 60% rated speed: 15-60min (depending on ambient temperautre and mounting situation)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6224 ERR_ENGINE_EEC_DIESEL_EX_FLUID_DOSING_UNIT_CIRC_OPEN esWarning A34 A140 ACM, SPN: 3361

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Reductant Injection Valve Circuit/Open Bank 1 Unit 1 MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 149 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6225 ERR_ENGINE_EEC_DIESEL_EX_FLUID_DOSING_UNIT_DEFECT esWarning A34 A140 ACM, SPN: 3361

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


31 Condition exists - - -
Causes Comment
C1 Reductant Dosing Unit Defect MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6226 ERR_ENGINE_EEC_SCR_QUALITY_SENSOR_TEMPERATURE2 esWarning A34 A140 ACM, SPN: 3515

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 MU_ISP_UQS_T_UREA_ERR MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6227 ERR_ENGINE_EEC_SCR_QUALITY_SENSOR_QUALITY esWarning A34 A140 ACM, SPN: 3516

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 MU_SCR_DIA_UQS_PCT_UREA MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 150 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6228 ERR_ENGINE_EEC_SCR_QUALITY_SENSOR_QUALITY_NO_COMM esWarning A34 A140 ACM, SPN: 3516

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Urea Quality Sensor Missing CAN Signal MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6229 ERR_ENGINE_EEC_SCR_QUALITY_SENSOR_QUALITY_RANGE esWarning A34 A140 ACM, SPN: 3516

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 Reductant Quality Sensor Circuit Range/Performance MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6230 ERR_ENGINE_EEC_SCR_ADBLUE_LEVEL_LOW_10_PERC esWarning A34 A140 ACM, SPN: 3517

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


17 Data valid, but below normal operational range - least severe level - - -
Causes Comment
C1 Reductant Level Too Low MTU: Tank
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 151 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6231 ERR_ENGINE_EEC_SCR_ADBLUE_LEVEL_LOW_7_5PERC esWarning A34 A140 ACM, SPN: 3517

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 Reductant Level Too Low MTU: Tank
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6232 ERR_ENGINE_EEC_SCR_ADBLUE_LEVEL_LOW_5_PERC esWarning A34 A140 ACM, SPN: 3517

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Reductant Level Too Low MTU: Tank
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6233 ERR_ENGINE_EEC_SCR_ADBLUE_LEVEL_LOW_2_5PERC esWarning A34 A140 ACM, SPN: 3517

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Reductant Level Too Low MTU: Tank
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 152 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6234 ERR_ENGINE_EEC_SCR_ADBLUE_LEVEL_LOW_ERROR esWarning A34 A140 ACM, SPN: 3517

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error - - -
Causes Comment
C1 MU_ISP_CAN_L_UREA_TANK_ERR MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6235 ERR_ENGINE_EEC_SCR_ADBLUE_LEVEL_LOW_0_PERC esWarning A34 A140 ACM, SPN: 3517

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


31 Condition exists - - -
Causes Comment
C1 Reductant Level Too Low MTU: Tank
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6236 ERR_ENGINE_EEC_ECU_POWER_OUTPUT_SUPPLY_VOLTAGE_1 esWarning A34 A140 ACM, SPN: 3597

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 High Side Digital Output 1 Circuit Failed Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on, ignition turned off including after run
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 153 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6237 ERR_ENGINE_EEC_SCR_ADBLUE_ABSOLUTE_PRESS_CIRC_LOW esWarning A34 A140 ACM, SPN: 4334

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Reductant Pressure Sensor Circuit Low MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6238 ERR_ENGINE_EEC_SCR_ADBLUE_ABSOLUTE_PRESS_CIRC_HIGH esWarning A34 A140 ACM, SPN: 4334

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Reductant Pressure Sensor Circuit High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6239 ERR_ENGINE_EEC_SCR_CATALYST_IN_GAS_TEMP_CIRC_LOW esWarning A34 A140 ACM, SPN: 4360

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit Low Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 154 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6240 ERR_ENGINE_EEC_SCR_CATALYST_IN_GAS_TEMP_CIRC_HIGH esWarning A34 A140 ACM, SPN: 4360

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit High Bank 1 Sensor 1 MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6241 ERR_ENGINE_EEC_SCR_CATALYST_IN_GAS_TEMP_RANGE esWarning A34 A140 ACM, SPN: 4360

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


10 Abnormal rate of change - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with 1000<n<2600 & M>30% & T_SCR_IN>100°C for t>285s
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6242 ERR_ENGINE_EEC_SCR_CATALYST_OUT_GAS_TEMP_CIRC_LOW esWarning A34 A140 ACM, SPN: 4363

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit Low Bank 1 Sensor 2 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 155 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6243 ERR_ENGINE_EEC_SCR_CATALYST_OUT_GAS_TEMP_CIRC_HIGH esWarning A34 A140 ACM, SPN: 4363

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit High Bank 1 Sensor 2 MTU: Tier4 - > final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6244 ERR_ENGINE_EEC_SCR_CATALYST_OUT_GAS_TEMP_RANGE esWarning A34 A140 ACM, SPN: 4363

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


10 Abnormal rate of change - - -
Causes Comment
C1 Catalyst Temperature Sensor Circuit Range/Performance Bank 1 Sensor 2 MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with 1000<n<2600 & M>30% & T_SCR_IN>100°C for t>485s
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6245 ERR_ENGINE_EEC_SCR_CATALYST_CONVERSION_EFFICIENCY esWarning A34 A140 ACM, SPN: 4364

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 SCR NOX Conversion Efficiency Very Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 At active severe Indc. (trq<50%): healing with engine running within NTE-Zone for at least 2 min (1200 samples) with Eta_Nox>14-20% (depending on load condition.)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 156 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6246 ERR_ENGINE_EEC_SCR_ADBLUE_PUMP_MOTOR_SPEED_CIRC_HIGH esWarning A34 A140 ACM, SPN: 4374

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Pump Speed Signal Circuit High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6247 ERR_ENGINE_EEC_SCR_ADBLUE_PUMP_MOTOR_SPEED_CIRC_LOW esWarning A34 A140 ACM, SPN: 4374

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Pump Speed Signal Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6248 ERR_ENGINE_EEC_SCR_ADBLUE_PUMP_MOTOR_SPEED_HIGH esWarning A34 A140 ACM, SPN: 4374

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level - - -
Causes Comment
C1 Reductant Pump Speed Too High For Given Pressure MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Engine running (20% torque is enough)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 157 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6249 ERR_ENGINE_EEC_SCR_ADBLUE_PUMP_DRIVE_CONTR_CIRC_LOW esWarning A34 A140 ACM, SPN: 4375

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Reductant Pump "A" Control Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6250 ERR_ENGINE_EEC_SCR_ADBLUE_PUMP_DRIVE_CONTR_CIRC_HIGH esWarning A34 A140 ACM, SPN: 4375

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Reductant Pump "A" Control Circuit High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine running (20% torque is enough)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6251 ERR_ENGINE_EEC_SCR_ADBLUE_PUMP_DRIVE_CONTR_CIRC_OPEN esWarning A34 A140 ACM, SPN: 4375

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Reductant Pump "A" Control Circuit/Open MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 158 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6252 ERR_ENGINE_EEC_ECU_POWER_OUTPUT_SUPPLY_VOLTAGE_4 esWarning A34 A140 ACM, SPN: 5016

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Coolant Valve Supply Voltage Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on, ignition turned off including after run
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6253 ERR_ENGINE_EEC_ECU_POWER_OUTPUT_SUPPLY_VOLTAGE_5 esWarning A34 A140 ACM, SPN: 5017

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 High Side Digital Output 5 Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on, ignition turned off including after run
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6254 ERR_ENGINE_EEC_SCR_CATALYST_REAGENT_PUMP_BLOCKED esWarning A34 A140 ACM, SPN: 5435

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


7 Mechanical system not responding or or out of adjustment - - -
Causes Comment
C1 Reductant Pump Blocked MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine running (20% torque is enough)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 159 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6255 ERR_ENGINE_EEC_PROP_NOX_MASS_NOT_AVAIL_VIA_CAN esWarning A34 A140 ACM, SPN: 520232

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 NOx Mass Signal Not Available via CAN MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6256 ERR_ENGINE_EEC_PROP_LOST_COMM_NOX_SENSOR_OUTLET esWarning A34 A140 ACM, SPN: 520299

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Lost Communication With NOX Sensor "B" MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6257 ERR_ENGINE_EEC_PROP_FAILURE_UREA_DOSING_UNIT esWarning A34 A140 ACM, SPN: 520315

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


31 Condition exists - - -
Causes Comment
C1 Reductant Dosing Unit Defect MTU: no inducement ?
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 160 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6258 ERR_ENGINE_EEC_PROP_FAILURE_UREA_SUPPLY_UNIT esWarning A34 A140 ACM, SPN: 520316

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


31 Condition exists - - -
Causes Comment
C1 Reductant Supply Unit Defect MTU: no inducement ?
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6259 ERR_ENGINE_EEC_PROP_DIGITAL_OUT_DOSING_VALVE_COOL esWarning A34 A140 ACM, SPN: 520323

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 High Side Digital Output Reductant Dosing Valve Circuit Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6260 ERR_ENGINE_EEC_PROP_FAILURE_UREA_SUPPLY_UNIT_2 esWarning A34 A140 ACM, SPN: 520329

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


31 Condition exists - - -
Causes Comment
C1 Reductant Supply Unit Defect MTU: Tier4 -> final
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 161 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6261 ERR_ENGINE_EEC_PROP_ATS_DIA_RD_T_MIXER esWarning A34 A140 ACM, SPN: 520354

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


10 Abnormal rate of change - - -
Causes Comment
C1 MU_ATS_DIA_RD_T_MIXER MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with 1000<n<2600 & M>30% & T_SCR_IN>100°C for t>285s
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6262 ERR_ENGINE_EEC_MDEG_AM_EGR_CLS_POS_DIAG esWarning A34 A44 MCM, SPN: 27

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level - - -
Causes Comment
C1 EGR Valve Failed to Attain Closed Position MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6263 ERR_ENGINE_EEC_MDEG_AM_EGR_OPN_POS_DIAG esWarning A34 A44 MCM, SPN: 27

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 EGR Valve Failed to Attain Open Position MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 failure can only occur, if end position is never reached. Failure can be deactivated. Not needed.
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 162 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6264 ERR_ENGINE_EEC_MDEG_EGR_VALVE_POS_CIRC_HIGH esWarning A34 A44 MCM, SPN: 27

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 EGR Valve Position Circuit Failed High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6265 ERR_ENGINE_EEC_MDEG_EGR_VALVE_POS_CIRC_LOW esWarning A34 A44 MCM, SPN: 27

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 EGR Valve Position Circuit Failed Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6266 ERR_ENGINE_EEC_MDEG_INTAKE_MANIFOLD_PRESS_LOW esWarning A34 A44 MCM, SPN: 102

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Intake Manifold Pressure too Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 163 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6267 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_SENSOR_SIGNAL esWarning A34 A44 MCM, SPN: 157

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


2 Data erratic, intermittent or incorrect - - -
Causes Comment
C1 Fuel Rail Pressure Sensor Signal Erratic MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 engine at least at idle speed
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6268 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_LOW esWarning A34 A44 MCM, SPN: 157

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level - - -
Causes Comment
C1 Fuel Rail Pressure too Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6269 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_HIGH esWarning A34 A44 MCM, SPN: 157

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Fuel Rail Pressure too High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 164 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6270 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_SENSOR_CIRC_HIGH esWarning A34 A44 MCM, SPN: 164

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Rail Pressure Sensor Circuit Failed High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6271 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_SENSOR_CIRC_LOW esWarning A34 A44 MCM, SPN: 164

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Rail Pressure Sensor Circuit Failed Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6272 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_SENSOR_CIRC_OPEN esWarning A34 A44 MCM, SPN: 164

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Rail Pressure Sensor Circuit Failed Open MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 165 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6273 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_SENSOR_DRIFT_HIGH esWarning A34 A44 MCM, SPN: 164

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


20 Data drifted high - - -
Causes Comment
C1 Rail Pressure Sensor, Signal Drift (High) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6274 ERR_ENGINE_EEC_MDEG_FUEL_P_RAIL_SENSOR_DRIFT_LOW esWarning A34 A44 MCM, SPN: 164

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


21 Data drifted low - - -
Causes Comment
C1 Rail Pressure Sensor, Signal Drift (Low) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6275 ERR_ENGINE_EEC_MDEG_CAN_NO_COM_TO_ACM_STAGE2 esWarning A34 A44 MCM, SPN: 625

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


17 Data valid, but below normal operational range - least severe level - - -
Causes Comment
C1 No ACM Communication - Pre Warning MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 166 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6276 ERR_ENGINE_EEC_MDEG_CAN_NO_COM_TO_ACM_STAGE3 esWarning A34 A44 MCM, SPN: 625

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 No ACM Communication - Warning MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6277 ERR_ENGINE_EEC_MDEG_OFD_CYL1_INJ_PUSH_MAX esWarning A34 A44 MCM, SPN: 651

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Injector Cylinder #1 Needle Control Valve, Abnormal Operation (MAX) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6278 ERR_ENGINE_EEC_MDEG_OFD_CYL1_INJ_PUSH_MIN esWarning A34 A44 MCM, SPN: 651

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Injector Cylinder #1 Needle Control Valve, Abnormal Operation (MIN) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 167 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6279 ERR_ENGINE_EEC_MDEG_OFD_CYL1_INJ_OPEN_LOAD esWarning A34 A44 MCM, SPN: 651

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Injector Cylinder #1, Needle Control Valve Circuit Open MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6280 ERR_ENGINE_EEC_MDEG_OFD_CYL1_INJ_VSC esWarning A34 A44 MCM, SPN: 651

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit - - -
Causes Comment
C1 Injector Cylinder #1 Needle Control Valve, Valve Shorted Circuit MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6281 ERR_ENGINE_EEC_MDEG_OFD_CYL2_INJ_PUSH_MAX esWarning A34 A44 MCM, SPN: 652

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Injector Cylinder #2 Needle Control Valve, Abnormal Operation (MAX) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 168 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6282 ERR_ENGINE_EEC_MDEG_OFD_CYL2_INJ_PUSH_MIN esWarning A34 A44 MCM, SPN: 652

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Injector Cylinder #2 Needle Control Valve, Abnormal Operation (MIN) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6283 ERR_ENGINE_EEC_MDEG_OFD_CYL2_INJ_OPEN_LOAD esWarning A34 A44 MCM, SPN: 652

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Injector Cylinder #2 Needle Control Valve, Circuit Open MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6284 ERR_ENGINE_EEC_MDEG_OFD_CYL2_INJ_VSC esWarning A34 A44 MCM, SPN: 652

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit - - -
Causes Comment
C1 Injector Cylinder #2 Needle Control Valve, Valve Shorted Circuit MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 169 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6285 ERR_ENGINE_EEC_MDEG_OFD_CYL3_INJ_PUSH_MAX esWarning A34 A44 MCM, SPN: 653

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Injector Cylinder #3 Needle Control Valve, Abnormal Operation (MAX) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6286 ERR_ENGINE_EEC_MDEG_OFD_CYL3_INJ_PUSH_MIN esWarning A34 A44 MCM, SPN: 653

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Injector Cylinder #3 Needle Control Valve, Abnormal Operation (MIN) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6287 ERR_ENGINE_EEC_MDEG_OFD_CYL3_INJ_OPEN_LOAD esWarning A34 A44 MCM, SPN: 653

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Injector Cylinder #3 Needle Control Valve, Circuit Open MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 170 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6288 ERR_ENGINE_EEC_MDEG_OFD_CYL3_INJ_VSC esWarning A34 A44 MCM, SPN: 653

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit - - -
Causes Comment
C1 Injector Cylinder #3 Needle Control Valve, Valve Shorted Circuit MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6289 ERR_ENGINE_EEC_MDEG_OFD_CYL4_INJ_PUSH_MAX esWarning A34 A44 MCM, SPN: 654

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Injector Cylinder #4 Needle Control Valve, Abnormal Operation (MAX) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6290 ERR_ENGINE_EEC_MDEG_OFD_CYL4_INJ_PUSH_MIN esWarning A34 A44 MCM, SPN: 654

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Injector Cylinder #4 Needle Control Valve, Abnormal Operation (MIN) MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 171 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6291 ERR_ENGINE_EEC_MDEG_OFD_CYL4_INJ_OPEN_LOAD esWarning A34 A44 MCM, SPN: 654

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Injector Cylinder #4 Needle Control Valve, Circuit Open MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6292 ERR_ENGINE_EEC_MDEG_OFD_CYL4_INJ_VSC esWarning A34 A44 MCM, SPN: 654

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit - - -
Causes Comment
C1 Injector Cylinder #4 Needle Control Valve, Valve Shorted Circuit MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6301 ERR_ENGINE_EEC_MDEG_FUEL_CONTROL_VALVE_LOW esWarning A34 A44 MCM, SPN: 1077

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Quantity Control Valve (Low Side) Error MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 172 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6302 ERR_ENGINE_EEC_MDEG_FUEL_CONTROL_VALVE_HIGH esWarning A34 A44 MCM, SPN: 1077

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Quantity Control Valve (High Side) Error MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6303 ERR_ENGINE_EEC_MDEG_FUEL_CONTROL_VALVE_NO_CURR esWarning A34 A44 MCM, SPN: 1077

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 Quantity Control Valve Error, Current too Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6304 ERR_ENGINE_EEC_MDEG_FUEL_CONTROL_VALVE_WRONG_CURR esWarning A34 A44 MCM, SPN: 1077

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit - - -
Causes Comment
C1 Quantity Control Valve, Desired Current Doesn't Match Actual Current MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 173 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6305 ERR_ENGINE_EEC_MDEG_EGR_DEV_HIGH esWarning A34 A44 MCM, SPN: 1118

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 EGR Flow Rate too High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with 1400<n & M>35%
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6306 ERR_ENGINE_EEC_MDEG_MFD_CYL1_MISFIRE esWarning A34 A44 MCM, SPN: 1323

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 Cylinder #1 Misfire Detected MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6307 ERR_ENGINE_EEC_MDEG_MFD_CYL2_MISFIRE esWarning A34 A44 MCM, SPN: 1324

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 Cylinder #2 Misfire Detected MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 174 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6308 ERR_ENGINE_EEC_MDEG_MFD_CYL3_MISFIRE esWarning A34 A44 MCM, SPN: 1325

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 Cylinder #3 Misfire Detected MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6309 ERR_ENGINE_EEC_MDEG_MFD_CYL4_MISFIRE esWarning A34 A44 MCM, SPN: 1326

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 Cylinder #4 Misfire Detected MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6312 ERR_ENGINE_EEC_MDEG_CCF_EXCESS_SMOKE_MODE esWarning A34 A44 MCM, SPN: 2631

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


1 Data valid, but below normal operational range - most severe level - - -
Causes Comment
C1 Unexceptable Long Time in Smoke Mode MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 175 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6313 ERR_ENGINE_EEC_MDEG_BANK1_INJ_CIRC_LOW esWarning A34 A44 MCM, SPN: 2797

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Injector Needle Control Valve Cylinder #1, #2, #3, Shorted to Battery MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6314 ERR_ENGINE_EEC_MDEG_BANK1_INJ_CIRC_HIGH esWarning A34 A44 MCM, SPN: 2797

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Injector Needle Control Valve Cylinder #1, #2, #3, Shorted to Ground MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6315 ERR_ENGINE_EEC_MDEG_BANK2_INJ_CIRC_LOW esWarning A34 A44 MCM, SPN: 2798

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Injector Needle Control Valve Cylinder #4, #5, #6, Shorted to Battery MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 176 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6316 ERR_ENGINE_EEC_MDEG_BANK2_INJ_CIRC_HIGH esWarning A34 A44 MCM, SPN: 2798

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Injector Needle Control Valve Cylinder #4, #5, #6, Shorted to Ground MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6317 ERR_ENGINE_EEC_MDEG_ISP_USV5_1_CIRC_HIGH esWarning A34 A44 MCM, SPN: 3509

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 5V Sensor Supply Bank 1 Circuit Failed High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6318 ERR_ENGINE_EEC_MDEG_ISP_USV5_1_CIRC_LOW esWarning A34 A44 MCM, SPN: 3509

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 5V Sensor Supply Bank 1 Circuit Failed Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 177 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6319 ERR_ENGINE_EEC_MDEG_ISP_USV5_2_CIRC_HIGH esWarning A34 A44 MCM, SPN: 3510

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 5V Sensor Supply Bank 2 Circuit Failed High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6320 ERR_ENGINE_EEC_MDEG_ISP_USV5_2_CIRC_LOW esWarning A34 A44 MCM, SPN: 3510

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 5V Sensor Supply Bank 2 Circuit Failed Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6321 ERR_ENGINE_EEC_MDEG_ECU_POWER_SUP_VOLT_HIGH esWarning A34 A44 MCM, SPN: 3599

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 MCM Internal Injector Power Supply Failed High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 178 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6322 ERR_ENGINE_EEC_MDEG_ECU_POWER_SUP_VOLT_LOW esWarning A34 A44 MCM, SPN: 3599

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 MCM Internal Injector Power Supply Failed Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6323 ERR_ENGINE_EEC_MDEG_EGR_COOL_FAIL esWarning A34 A44 MCM, SPN: 4752

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


16 Data valid, but above normal operational range - moderately severe level - - -
Causes Comment
C1 Cooling Efficiency of EGR Cooler too Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Driving with 1300<n & M>40%
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6324 ERR_ENGINE_EEC_MDEG_EPF_TEMP_EXH_GAS_HIGH esWarning A34 A44 MCM, SPN: 4765

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


0 Data valid, but above normal operational range - most severe level - - -
Causes Comment
C1 Exhaust temperature too high, most likely fault in either engine gas-path or component MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 179 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6325 ERR_ENGINE_EEC_MDEG_RC4_P_INT_DEV_LOW_CEL esWarning A34 A44 MCM, SPN: 5312

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


7 Mechanical system not responding or or out of adjustment - - -
Causes Comment
C1 The set point signal and the actual sensor signal for the intake manifold pressure MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6326 ERR_ENGINE_EEC_MDEG_RPG_OPEN_LOOP_ERROR esWarning A34 A44 MCM, SPN: 5323

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


13 Out of calibration - - -
Causes Comment
C1 Excessive Time to Enter Closed Loop Fuel Pressure Control MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6327 ERR_ENGINE_EEC_MDEG_ESC_CYL1_SMOOTHNESS esWarning A34 A44 MCM, SPN: 5358

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Engine Smoothness Control / Cylinder #1 Quantity Excess MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 180 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6328 ERR_ENGINE_EEC_MDEG_ESC_CYL2_SMOOTHNESS esWarning A34 A44 MCM, SPN: 5359

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Engine Smoothness Control / Cylinder #2 Quantity Excess MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6329 ERR_ENGINE_EEC_MDEG_ESC_CYL3_SMOOTHNESS esWarning A34 A44 MCM, SPN: 5360

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Engine Smoothness Control / Cylinder #3 Quantity Excess MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6330 ERR_ENGINE_EEC_MDEG_ESC_CYL4_SMOOTHNESS esWarning A34 A44 MCM, SPN: 5361

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


18 Data valid, but below normal operational range - moderately severe level - - -
Causes Comment
C1 Engine Smoothness Control / Cylinder #4 Quantity Excess MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 181 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6333 ERR_ENGINE_EEC_MDEG_CMP_PVH_FMU_CIRC_HIGH esWarning A34 A44 MCM, SPN: 5418

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 FMU High Side Short-Circuit to Battery MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6334 ERR_ENGINE_EEC_MDEG_OFD_FMU_CIRC_LOW esWarning A34 A44 MCM, SPN: 5418

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 FMU Low Side Short-Circuit to Ground MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6335 ERR_ENGINE_EEC_MDEG_RPG_I_PCV_NO_CURR esWarning A34 A44 MCM, SPN: 5571

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 PCV Current too Low MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 182 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6336 ERR_ENGINE_EEC_MDEG_RPG_I_PCV_WRONG_CURR esWarning A34 A44 MCM, SPN: 5571

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


6 Current above normal or grounded circuit - - -
Causes Comment
C1 PCV Current Deviation too High MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6337 ERR_ENGINE_EEC_MDEG_CMP_PVH_HB_2_SC_CIRC_HIGH esWarning A34 A44 MCM, SPN: 5928

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 H Bridge 2 EGR Valve Circiut Shorted to Battery MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6338 ERR_ENGINE_EEC_MDEG_CMP_PVH_HB_2_SC_CIRC_LOW esWarning A34 A44 MCM, SPN: 5928

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 H Bridge 2 EGR Valve Circuit Shorted to Ground MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 183 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6339 ERR_ENGINE_EEC_MDEG_CMP_PVH_HB_2_SC_OVERCURR esWarning A34 A44 MCM, SPN: 5928

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit - - -
Causes Comment
C1 H Bridge 2 EGR Valve Short Circuit/ Over Current MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Failure will not heal by itself. Service Routine via Vedoc necessaray (Xentry)
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6340 ERR_ENGINE_EEC_MDEG_CMP_PVH_HB_2_CIRC_OPEN esWarning A34 A44 MCM, SPN: 5928

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 H Bridge 2 EGR Valve Circuit Open Load MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6341 ERR_ENGINE_EEC_MDEG_CMP_PVH_PCV_CIRC_HIGH esWarning A34 A44 MCM, SPN: 520251

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 PCV High Side Short-Circuit to Battery MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 184 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6342 ERR_ENGINE_EEC_MDEG_CMP_PVH_PCV_HS2GND esWarning A34 A44 MCM, SPN: 520251

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 Pressure Control Valve (High Side) Error MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6343 ERR_ENGINE_EEC_MDEG_CMP_PVH_PCV_LS2BATT esWarning A34 A44 MCM, SPN: 520252

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Pressure Control Valve (Low Side) Error MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Engine at least at idle speed
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
6344 ERR_ENGINE_EEC_MDEG_OFD_PCV_CIRC_LOW esWarning A34 A44 MCM, SPN: 520252

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source - - -
Causes Comment
C1 PCV Low Side Short-Circuit to Ground MTU: Stage4 -> severe
C2 -
C3 -

Solutions
S1 Ignition turned on
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 185 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7501 ERR_INTERCOM_DO_GENERIC_ON_SCU_MCU_LINE_BREAK esPartialError A34 K161 Relay, GEN-ON

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:61 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7502 ERR_INTERCOM_DO_GENERIC_ON_SCU_MCU_SHORT_GND esPartialError A34 K161 Relay, GEN-ON

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


5 Current below normal or open circuit X35:61 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7503 ERR_INTERCOM_DO_GENERIC_ON_SCU_MCU_SHORT_UB esPartialError A34 K161 Relay, GEN-ON

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:61 - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 186 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7505 ERR_INTERCOM_HW_INTERF_CONFIG_SCU_BY_PRESELECT_PINS_FAILED esWarning A34 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7506 ERR_INTERCOM_HW_INTERF_CONFIG_MCU_BY_PRESELECT_PINS_FAILED esWarning A34 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7507 ERR_INTERCOM_COMPA_CHECK_MCU_SCU_VERSION_NOT_EQUAL esFunctionInterference A34 - -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 187 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7508 ERR_INTERCOM_COMPA_CHECK_TCU_VERSION_NOT_COMPATIBLE_WITH_MCU esFunctionInterference A34 - -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
7509 ERR_INTERCOM_COMPA_CHECK_TCU_VERSION_NOT_COMPATIBLE_WITH_SCU esFunctionInterference A34 - -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


14 Special instructions - - -
Causes Comment
C1 - -
C2 -
C3 Required condtions not achieved

Solutions
S1 Follow corresponding instructions in service manual
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8001 ERR_EE_BUSY_READ esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 188 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8002 ERR_EE_BUSY_WRITE esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8006 ERR_EE_SEG esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8007 ERR_EE_VERIFY esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 189 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8008 ERR_EE_MAX_READ_BYTES esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8009 ERR_EE_REDUNDANT_CHECK esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8010 ERR_EE_UNKOWN_RESULT esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 190 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8011 ERR_EE_SPI_COMM_FAULT esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8012 ERR_EE_RANGE esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8013 ERR_EE_READ esPartialError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 191 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8016 ERR_EE_LIFTIME_END esWarning A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8019 ERR_PARAM_READ_INDEX_DOES_NOT_MATCH esFatalError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8020 ERR_SET_LOCAL_ID_UNKNOWN_RESULT esFatalError A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 192 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8027 ERR_EE_DASA_WRITE esFunctionInterference A34 A34 -

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


11 Root cause not known - - -
Causes Comment
C1 - -
C2 -
C3 -

Solutions
S1 If available, use special diagnostic tools for this device
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8970 ERR_VOLTAGE_HIGH_8_5_V_OUTPUT esFatalError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


3 Voltage above normal or shorted to high source X35:23 __A34_8_5_V_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing connection to ground
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8971 ERR_VOLTAGE_LOW_8_5_V_OUTPUT esFatalError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:23 __A34_8_5_V_Output -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

_error_list_BF800C_2015_06_12.xls 193 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8980 ERR_SUPPLY_VOLTAGE_WARNING esWarning A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:56 - X35:60 __A34_Supply_Voltage_Outputs -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
8981 ERR_SUPPLY_VOLTAGE_SHUT_DOWN esPartialError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


4 Voltage below normal or shorted to low source X35:56 - X35:60 __A34_Supply_Voltage_Outputs -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Missing power supply
C3 Faulty actuator or input/ sensor device

Solutions
S1 Repair harness / connector
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9005 ERR_CAN_BUSOFF_1 esPartialError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 194 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9012 ERR_CAN_OBJ_2_RX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9013 ERR_CAN_OBJ_3_RX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9014 ERR_CAN_OBJ_4_RX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 195 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9015 ERR_CAN_OBJ_5_RX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9021 ERR_CAN_OBJ_11_RX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9025 ERR_CAN_OBJ_15_RX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 196 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9026 ERR_CAN_TX_BUFF_OVERFLOW_1 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:26, X35:27 __A34_CAN1 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9055 ERR_CAN_BUSOFF_2 esPartialError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9062 ERR_CAN_OBJ_2_RX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 197 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9063 ERR_CAN_OBJ_3_RX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9064 ERR_CAN_OBJ_4_RX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9065 ERR_CAN_OBJ_5_RX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 198 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9071 ERR_CAN_OBJ_11_RX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9075 ERR_CAN_OBJ_15_RX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9076 ERR_CAN_TX_BUFF_OVERFLOW_2 esFunctionInterference A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


19 Received network data in error X35:33, X35:53 __A34_CAN2 -
Causes Comment
C1 Bad connection in harness, connector or central electric Ensure that electronic engine controller is working.
C2 Short or open circuit of CAN wires
C3 Missing termination resistor

Solutions
S1 Repair harness / connector
S2 -
S3 Ensure correct baudrate setting

_error_list_BF800C_2015_06_12.xls 199 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9091 ERR_DXCHANGE_RX_INDEX_NOT_VALID esPartialError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9092 ERR_DXCHANGE_TX_INDEX_NOT_VALID esPartialError A34 A34 Tractor control unit (TCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


12 Bad intelligent device or component - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 Wrong device setting / configuration
C3 Faulty actuator or input/ sensor device

Solutions
S1 -
S2 -
S3 Replace actuator or input/ sensor device

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9111 ERR_CANOPEN_NODE_REQUEST_TIMEOUT_NODE_11_CO_1 esFunctionInterference A34 A81 Display Unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 200 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9145 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_5_CO_1 esFunctionInterference A34 A122 Material flow control unit (MCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9147 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_7_CO_1 esFunctionInterference A34 A121 Screed control unit (SCU)

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9150 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_10_CO_1 esFunctionInterference A34 A80 Module, data collector

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 201 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9151 ERR_CANOPEN_NODE_PROCESS_PDO_TIMEOUT_NODE_11_CO_1 esFunctionInterference A34 A81 Display Unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9270 ERR_CANOPEN_NODE_MESSAGE_COUNTER_NODE_10_CO_1 esWarning A34 A80 Module, data collector

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9271 ERR_CANOPEN_NODE_MESSAGE_COUNTER_NODE_11_CO_1 esWarning A34 A81 Display Unit

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 202 of 203


BF600-2 C, BF700 C, BF800 C, BF900 C - Error Code List

Actuator /
Input Device /
DispTC Fault Description Fault Reaction Control Unit Sensor Device BSPN
9400 ERR_ENGINE_EMC_CAN_BUS esFunctionInterference A34 A48 Electronical engine controller

BFMI # BFMI Text Terminal Signal Display Code for Diagnosis


9 Abnormal update rate - - -
Causes Comment
C1 Bad connection in harness, connector or central electric -
C2 -
C3 CAN device not connected to power supply

Solutions
S1 Repair harness / connector
S2 -
S3 -

_error_list_BF800C_2015_06_12.xls 203 of 203