Thar Process, Inc. • 150 Gamma Drive• Pittsburgh, PA 15238 • www.tharprocess.com • 412.968.

0200

SuperFastTM 2x120L CO2 Extraction System – Technical Specifications


Extraction Vessel: 2x120L Extraction Vessel
• Design pressure: 5,000 psi (345 bar)
• Design temp: 80°C
• Max. operating pressure: 4,350 psi (300 bar)
• Max. operating temp: 30-60 °C
• Jacket Type: None
• Heat Exchanger: Designed for heating mode
• Baskets are custom designed for high-efficiency fluidization for optimal
extraction and near-zero gradient
• Basket Payload Volume: 100L
• Hoist provided for ease of basket access and manipulation

Maximum operating conditions may vary based on process characteristics.

Collection vessels: 2 x 75 L Separators


• Design pressure: 2,500 psi (172 bar) Medium Pressure
1,200 psi (82 bar) Low Pressure
• Design temp: 80°C
• Max. Operating Pressure: 2,175 psi (150 bar) Medium Pressure
870 psi (60 bar) Low Pressure
• Jacket Type: Welded On
• MP Heat Exchanger: Designed for heating mode
• LP Heat Exchanger: Designed for heating mode

Recirculation System: 1x 420L Receiver


• Design pressure: 1,088 psi (75 bar)
• Design temp: 80°C
• Max. Operating Pressure: 870 psi (60 bar)
• Heat Exchanger(s): Condensing and sub-cooling for receiver pressure
control and pump flow
• Maximum CO2 flow rate: 20 kg/min

✓ All pressure vessels are designed in accordance with ASME Section VIII, Div. 1
✓ All pressure vessels are installed with ASME “UV” stamped safety pressure relief
valves.

Material of Construction:
• Process Equipment & Piping: Stainless Steel
• Equipment Skids: Stainless Steel
• Utility Piping: Stainless Steel/Brass
• Control Panel: Powder Coated Galvanized Steel

SuperFastTM 2x120L CO2 Extraction System – Technical Specification


Revision: 1
By: DTravis
Date: 10/18/19
Thar Process, Inc. • 150 Gamma Drive• Pittsburgh, PA 15238 • www.tharprocess.com • 412.968.0200

Control Specifications:
• Allen-Bradley Compact Logix PLC Controller with Factory Talk HMI frontend
• Windows based HMI providing operator controls for
start/stop/pressure/temp/flow control & monitoring features & safety Interlocks to
prevent over-pressurization
• Data logging & trending
• 24V DC Control Voltage
• All electrical drawings are PE stamped by an independent firm

Utility Requirements:
• Refer to datasheet – Utility Requirements - Thar SuperFastTM 2x120L CO2
Extraction System
• Contact sales for details.

Spacing Requirements: 45’ x 10’ x 16’ (L x W x H)

✓ A minimum of 10’ x 12’ (W x H) door opening required to haul the equipment

SuperFastTM 2x120L CO2 Extraction System Layout

SuperFastTM 2x120L CO2 Extraction System – Technical Specification


Revision: 1
By: DTravis
Date: 10/18/19