IMPACT TEST REPORT

Customer Name & Address: Work Order CMSS/20/0086


Report No/Date TC6850200000089P
Date of Receipt of test Item 15/09/2020
Date of testing 15/09/2020
NIKHIL Material EPOXY composite 
Sample Description Specified Below
(M-Tech Project)
Identification of the sample Specified Below
CMRIT

S.NO Test Details


Machine Details IMPACT TEST PARAMETERS

Name : FIE (IT-30D) Test Procedure : ISO 148-1: 2009


1 Type of Impact : CHARPY - V
Srl. No : 1357 Range: 0-300J
Calibration on Date : 06-12-2019 Notch Depth : 1.998mm
Calibration Due Date : 05-12-2020 Notch Angle : 45o
Specimen size : 10 x 6x 55mm
Test Temperature : RT

Observed Values in ( Joules)


Impact Value in
S.No Sample ID Impact Value in Joules S.No Sample ID
Joules
1
Sample 1 2.5 5. Sample 5 2.5
2
Sample 2 3.0 6. Sample 6 2.5
3
Sample 3 1.5 7. Sample 7 3.5
4
Sample 4 2.0 8. Sample 8 2.0
Verified by Witnessed by for CRYSTAL METALLURGICAL SERVICES & SOLUTIONS

Authorized Signatory
P.Naveen Kumar
Technical Manager

Page 1 of 1
Format No CMSS/FM/48A(IMP)
Rev No.00: DT; 01-01-2016