ETAP ® is the most

comprehensive electrical
engineering software solution
for the design, simulation, operation,
and automation of generation, transmission,
distribution, and industrial power systems.

ETAP is developed under an established quality Product


assurance program and is used worldwide as a high
impact software. ETAP is completely localized in Overview
seven languages with translated output reports in
eight languages.

As a fully integrated enterprise solution, ETAP


Enterprise Software Solution
extends to a Real-Time Power Management System
for Electrical Power Systems
to monitor, control, automate, simulate, and optimize
the operation of power systems.
Base Package
ETAP Base Package is a set of core tools, embedded analysis modules, and engineering libraries that allow you
to create, configure, customize, and manage your system model. Core tools allow you to quickly and easily build
3-phase and 1-phase AC and DC network one-line diagrams with unlimited buses and elements including detailed
instrumentation and grounding components. Engineering libraries provide complete verified and validated data based
on equipment manufacturers' published data.

System Elements Cable Manager


Embedded Analysis Modules • Unlimited AC & DC elements • Batch cable management
• 1-phase (2 & 3 Wire), 2-phase (2 & 3 Wire), • Customizable cable reports
• Cable Ampacity • Cable Constants
3-phase (3 & 4 Wire) • Multi-cable sizing & shock protection evaluation
• Cable Sizing • Transmission Line • Unlimited buses: license dependent at run-time • Intelligent search / filtering
• Nested views (composite networks & MCC)
• Cable Manager Constants Data Manager
• Power grid
• View / edit Base & Revision Data
• Synchronous & induction generators
• View equipment properties for individual fields
One-Line Diagram • Photovoltaic array (PV Interconnection Study)
• View equipment state & Service
• Built-in intelligent graphics • DC Photovoltaic array
• View absolute value or differences
• Automatic equipment connection mode • Wind Turbine Generator
• Display & filter data based on study type
• Network nesting • MOV, synchronous, & induction motors
• Graphical data management & merge per
• Integrated 1-phase, 3-phase, & DC systems • Exciters, governors, & stabilizers
individual equipment
• Integrated AC, DC, & grounding systems • Voltage & frequency dependent lumped load
• Multiple generators & grid connections • Cable, line, reactor, & impedance branches Theme Manager
• Display results on one-line diagrams • 2W & 3W transformers with voltage regulators • Display color coding based on:
• Customizable font types, styles, & colors • 2W & 3W transformers with buried delta winding - Standard
• Customizable display of ratings & results • Open-Delta transformer - Voltage level
• Graphical display of equipment grounding • Remote connectors - Area
• Graphical display of overstressed devices • Harmonic filter - Grounding (Solid, Low-Z, High-Z, Ungrounded)
& alerts • Static Var Compensator - Earthing (TT, TN, IT, NEC)
• Hide & show protective devices & • Instrument transformers (CT & VT) • Display faulted buses by symbol or color
grounding elements • Protective devices & meters
• Single & double throw switches
• Theme manager
• One-line templates • Grounding switch
• Propagation of nominal & rated voltage • Bus duct
• Propagation of phase connection • Batteries, DC motors, DC loads & branches
• Automatic display of energized & de-energized • Chargers
elements using dynamic continuity check • Inverters
• Text box editor with dynamic link to properties • UPS
• OLE object & ActiveX control integration • DC converter
• Intelligent text box & hyperlink bookmarks • Variable Frequency / Speed Drive (VFD / VSD)
• Customizable output reports via • ANSI, IEC, & user-defined symbols
Crystal Reports
Switching Device Interlock Enforcer
• Batch printing with view-dependent
• Auto enforcement of switching interlock logics
printer settings
• Automatic ‘pre’ & ‘post’ switching logic
• User-friendly plotting
verification
• Keyword based element search
• Interlock based on circuit breaker positions or
One-Line Diagram Templates meter readings
Multi-Dimensional Database
• Create & utilize unlimited one-line templates • Automatic interlock conflict checking
• Orthogonal multi-dimension database
• Ability to model cascade switching control
• Share templates created by other • Unlimited independent graphical views
• Active monitoring of switching interlock
ETAP engineers • Unlimited status configurations
violations
• Use default project ID or template ID • Unlimited property revisions
• Switching plan validation
• Use properties from the default project • Multiple loading & generation conditions
or templates Configuration Manager • Lock & unlock element properties
• Instant preview of templates • Tabulate & control different status configurations • 10 States to track equipment conditions
• Compare source, load, & switching device status • Utilize real-time operating data
• Flag changed data with checker capability • Unlimited study solutions
• Copy, merge, export, import, & print • ODBC – MS Access, SQL Server connectivity
• Dumpster with unlimited cells: copy & paste
• User access security with password protection
• Edited-by & checked-by with date stamping
• Merge project files via clipboard
Base Package
Base Package includes an intelligent one-line diagram, element editors, verified and validated engineering device
libraries, configuration manager, report manager, project and study wizards, multi-dimensional database, theme
manager, data exchange, and user access management. Embedded analysis modules, such as Cable Ampacity,
Cable Sizing, and Transmission Line Constants, provide integrated as well as stand-alone capabilities to design,
analyze, and size equipment.

Network Simulation Libraries


• Unlimited buses (license dependent) & elements • Comprehensive library (over 100,000 devices) Libraries
• Looped & radial systems • ANSI & IEC devices libraries
Cable
• Automatic error checking • Verified & Validated (V&V) library data
• User interface for all network analysis modules • V&V locked data Cable Fire Coating Protection
• Customizable ETAP preference properties • Add, copy, merge, & delete capabilities Cable Fire Stop Protection
• Multi-level user access management • User-defined & controlled libraries
Cable Fire Wrap Protection
• User-access control & security
Built-In Calculators • Edited-by & checked-by with date stamping Transmission Line
• MVA, MW, Mvar, kV, Amp, & PF conversion • User-controlled library merge Line Ground Conductor
• Motor nameplate & dynamic parameter data
• Generation nameplate Report Manager Motor Nameplate
• Power grid short circuit impedances • Customizable output reports & plots Motor CKT Model
• Motor & generation inertia • Input, results, alerts, & summary reports
Motor Characteristic Model
• Reports via Crystal Reports viewer
Output Report Comparator • PDF, Microsoft® Word, Access, & Excel reports Motor Load Model
• Built-in output report comparison tool • Element ID & text search capability Wind Turbine Generator
• Compare hundreds of study reports in one action • Multi-Language Report
• Verify study results against benchmark reports Photovoltaic Panel
License Manager Solar Panel
Project Management • Stand-Alone
• Manage studies with scenarios & macros Fuse
• Concurrent User LAN & WAN
• Record scenarios based on study settings • Network license checkout Recloser Hydraulic
• Macro-controlled scenario execution • License borrowing manager Recloser Electronic Controller
• Automatically compare & verify plots • Flexible license borrowing duration
• Export output data & plots to Excel HV Circuit Breaker
• License Manager configuration wizard utility
• Dynamic update of preferences LV Circuit Breaker
Multiple Language Support
• Interface & Help File in seven languages Solid State Trip

• Output reports in eight languages Thermal Magnetic
Electro-Magnetic

Motor Circuit Protector

Overload Heater
Harmonic

Interruption Cost
Localized Output Reports
Release In Every Release Reliability
Battery
English
Data Exchange (DataX) Base Control Contact
• Legacy program conversion to ETAP Chinese Control Relay
• Automatic one-line creation
Japanese Control Solenoid
• Protective device library mapping
• Convert using native file formats GFI / RCD
• Built-in conversions for SKM® Dapper® & Captor™, Russian
PSS®E, EasyPower® & others
Spanish
• WMF / EMF / DXF / PDF exporting
• Import RAW / IEEE / CSV files
Portuguese
• Export to AutoCAD® using DXF format
• Import ground grid plans from AutoCAD Korean
• Load Ticket for induction machines
German
Download a Free
Demo at etap.com
Modular

Network Analysis Arc Flash Protective Devices


Short-Circuit - ANSI / IEEE AC Arc Flash Coordination & Selectivity
• ANSI / IEEE C37 Standards • IEEE 1584 2002 & 2004 Standards • AC & DC coordination
• IEEE 141 & 399 Standards • NFPA® 70E 2000, 2004, & 2009 Standards • Graphically adjustable device settings
• UL® 489 Standard • CSA Z462 2008 Standard • Extensive device library (verified & validated)
• Integrates with protective device coordination • ASTM D 120-02a Standard • Embedded short circuit analysis
• Automatic device evaluation for 3-phase, • OSHA 29 CFR 1910 Standard • Embedded motor acceleration analysis
1-phase, & panel systems • National Electric Code® (NEC) 110.6 • Multi-axis time current curves
• Generator circuit breaker evaluation • National Electric Safety Code® (NESC) • Comprehensive plot options
• Phase-shifting transformer • Embedded short circuit & device coordination • Adjustable magnifying-glass zoom view
• Load terminal short circuit calculation • 3 & 1-Phase Arc Flash Sequence-of-Operation • Time difference calculator
• Graphical display of device trip sequence • Multi-function / level relays
Short-Circuit - IEC • Automatic verification of device duty • Device setting reports
• IEC 60909, 60282, 60781, & 60947 Standards
• User-defined incident energy correction factor • Automatic detection of protection zones
• Transient fault analysis - IEC 61363 Standard
• Current Limiting Fuse (CLF) modeling • Protection & coordination zone viewer
• Integrates with protective device coordination
• Incident Energy plots
• Automatic device evaluation for 3-phase,
• LV transformer arc flash limit Sequence-of-Operation
1-phase, & panel systems • View device operation sequence graphically
• Maintenance mode switch
• User-definable voltage c factor • Device failure & backup operation
• Relay actions (49, 50, 51, 67, 79, 87)
• Load terminal short circuit calculation • Sequence viewer
• Panels & single-phase systems
• Multi-report Result Analyzer • Normalized (shifted) curves
Short-Circuit - GOST • Current summation
• GOST R 52735 Standard • Labels, work permits, & data sheets
• Relay actions (27, 49, 50, 51, 51V, 59, 67, 79, 87)
• Calculate periodic & aperiodic components &
DC Arc Flash
surge current
• Maximum Power Method Relay Test Set Interface
• Consider pre-fault loading condition • Interfaces with testing & maintenance database
• Stokes & Oppenlander Method
• Calculation of short-circuit current at any • Export short circuit & protective relay settings
• Paukert Method
specified time • Plot device steady-state response
• Determine incident energy
• Radial & multi-loop circuit calculations • Compare relay response with OEM data
• Assess arc flash protection boundary
• Short circuit output report in Russian language • Display relay actual transient response
• Arc Flash Viewer
• Multi-report Result Analyzer • Analyze relay false trips & mis-operation
Load Flow • Export to COMTRADE format
• Power flow & demand load • Labels and work permits

• Voltage drop & power factor correction

• Automatic device evaluation

• Automatic temperature correction
• 2W & 3W transformer LTC / regulator actions
• Real & reactive power losses
• Extensive violation alerts
• Multi-report Result Analyzer
• Auto-Run load flow based on system changes
• Adaptive Newton-Raphson method Panel Systems User-Defined Dynamic Model
• Fast convergence for systems with
negligible impedance Panel ANSI & IEC • Full graphical model builder
• Handling of transmission series compensation • Intelligent panel design & analysis • Library of pre-built models
• 3-phase (3 & 4 Wire) panels • Integrated with transient stability models
Motor Acceleration • 1-phase (2 & 3 Wire) panels • Wide variety of blocks for building models
• Dynamic motor acceleration • 1-phase (A, B, C, AB, BC, CA, & 3 Wire) panels • Import & Export Simulink® models
• Voltage flicker • ANSI & IEC Standards • Various model testing methods
• Motor & load dynamic models • National Electric Code load factors • Real-time compiling & linking of model
• Static motor starting • Load flow with graphical per phase display • Automatic UDM links to components
• Multi-sequence starting • Automatic device duty evaluation & alerts • Compile & test directly from the UDM builder
• Conventional starting devices • Automatic updating of upstream panels
• Soft starter devices • Export panel schedules to Microsoft Excel
• VFD frequency control motor starting • Panel with internal & external feeders & loads
• Load & generation transitioning
• Motor Operated Valve (MOV) simulation
• Comprehensive alarm & warning
• Start motor individually or based on groups
Intuitive

Dynamics & Transients Renewable Energy Cable Sizing


Transient Stability Wind Turbine Generator Ampacity & Sizing
• Synchronous & induction machine models • Model unlimited wind turbine generators • IEEE 399 Standard
• Comprehensive excitation system models • Detailed modeling of turbine dynamics, • NFPA 70 - National Electric Code
• Comprehensive governor-turbine models aerodynamics, & power coefficients • ICEA P54 Standard
• Power System Stabilizer (PSS) models • DFIG with pitch & converter controller • IEC 60364-5-52, 60364-4-43 Standards
• GE, Westinghouse, & Solar gas turbines • Simulate wind disturbance like ramp & gust • BS 7671 Standard
• User-Defined Dynamic Models (UDM) • Individual or zone-based disturbances • Ampacity / Current Carrying Capacity
• Unlimited sequence of events & actions • WECC wind turbine models Calculator
• Typical & common disturbances & operations • WTG manufacturer / model library • Sizing based on ampacity, voltage drop, short
• Automatic actions based on relay settings circuit, harmonics, & overload protection
• Short-time & long-time simulation Photovoltaic Array • Maximum or average operating current
• Solar farm modeling • Armor & Sheath thermal calculation
• Variable total simulation time & simulation step
• Solar irradiance based on location & time • Grounding conductor selection based on NEC
• 3-phase & line-to-ground fault actions
• Performance adjustment coefficients • Cable Library with neutral, grounding /
• Auto-sync check action
• AC & DC System Analysis protective earthing (PE) conductor
• Embedded Newton-Raphson initial load flow
• Inverter dynamic modeling & operation modes • Add auxiliary neutral & PE conductors
• VFD / VSD dynamic modeling
• Maximum Peak Power Tracking (MPPT) • Optimal & alternative sizes
• Lumped Load user-defined dynamic modeling
• Constant current source modeling • Model Forms: BS & user-definable
• UPS parallel operation modeling
• Model PV systems with individual panels • Reports in Crystal Reports & Excel
• PV Array source modeling
• Model DC cables & combiner boxes
• Inverter source modeling
• Extensive Manufacturer/Model library Protective Earthing (PE) Conductor Sizing
• Automatically compare & verify plots
• P-V & I-V curves • IEC 60364-5-54 Standard
Generator Start-Up • BS 7671 Standard
• Cold-state generator starting • PE thermal requirements & sizing
• Load generators prior to synchronous speed • User-defined fault current & clearing time
• Frequency-dependent machine models • Reports in Crystal Reports & Excel
• Frequency-dependent network models • Consider leakage current
• An expansion to the Transient Stability module
Electric Shock Protection
• User-defined dynamic model interface
• IEC 60364-4-41 Standard
• BS 7671 Standard
Cable Systems • EN 50122 Standard
• TN-C, TN-S, TN-C-S, TT, & IT Earthing types
Underground Thermal Analysis • Electric shock requirements
• Neher-McGrath Method • Loop impedance & current calculation
• IEC 60287 Standard • Touch voltage calculation & evaluation
• Steady-state temperature • Consider resistance to Ground / Earth
• Ampacity optimization • GFCI / RCCB protection
Dynamic Parameter • Automatic cable sizing • Reports in Crystal Reports & Excel
Estimation & Tuning • Transient temperature
• Intelligent rule-based alignment & spacing tools
• Tune dynamic models with multiple inputs & outputs • Automatic conduit distribution & spacing

• Estimate parameters using field measurements • Uniform & non-uniform conduit arrangements

• Use field data from disturbance recorders & PMUs • Custom, NEC, or IEEE rule-based spacing
• Automatically exclude questionable data & noise
• Wizard for creating raceways
• Compliance with NERC MOD Standards
• Multi-objective stochastic optimization method Cable Pulling
• Utilize UDM to build custom models • Integrated with one-line diagram cables
• DPET Result Analyzer • Integrated with underground raceways cables Parameter Estimation
• Generate comparisons of multiple estimation results • Pull multiple cables
• Completely flexible pull geometry • Estimate induction machine equivalent
• Determine the best parameters to fit measured data
• Full ETAP cable library integration circuit parameters based on readily
• View parameter sensitivity
available manufacturer data
• Multiple sets of input/output data-files for • Display 3-D pulling path geometry
• Single-cage models
tuning comparison
• Rotor deep-bar effects
Integrated

Power Quality DC Systems Control Systems


Harmonic Load Flow Load Flow DC Control Systems Diagram
• IEEE 519 Standard • IEEE 946 Standard • Simulation of operation sequence
• Harmonics spectrum up to 250th order • Integrated AC & DC systems • Pickup & dropout voltage calculation
• Automatic distortion evaluation (THD & IHD) • Embedded Newton-Raphson Method • Automatic alerts
• Telephone influence factors (TIF & I*T) • Voltage drop • Burden & inrush modes
• Calculate & report I*TB (Balanced) • Power losses • Controlled contacts
& I*TR (Residual) • Battery auto-activation • Integrated with battery discharge calculation
• VFD harmonic modeling • Charger / UPS current limit • Integrated with one-line diagram
• UPS AC input & output modeling for • Charger / UPS mode auto-switching
• State engine with automatic & step-by-step
harmonic orders • DC converter modeling
sequence-of-operation of control relays,
• Motor model auto-switching
• PV Array modeling for harmonic orders switching actions, etc.
• Automatic alerts of violations Short Circuit
• Harmonic sources library • IEEE 946 Standard
• Embedded Adaptive Newton-Raphson Method • Integrated AC & DC systems
• Embedded Accelerated Gauss-Seidel Method • Total bus & branch contribution fault currents
• Fault current rising time
Interharmonics • Battery modeling per ANSI / IEC Standard
• Interharmonic modeling & simulation
• Charger modeling per ANSI / IEC Standard
• Perform voltage flicker limitation studies
• Interharmonic distortion indices calculation Battery Discharge & Sizing
based on IEC 61000-4-7 • IEEE 308, 485, & 946 Standards DataX Plus
• Adjustable harmonic current base • Integrated AC, DC, & Control System Diagram Microsoft® Excel Interface
• Automatic harmonic spectrum generation • Battery discharge simulation • Bi-directional Excel data exchange
• Automatic interharmonic frequency generation • Battery sizing (Open & Fixed Formats)
• Discharge via DC load flow or duty cycle • Map Excel worksheets to ETAP elements
Frequency Scan summation • Synchronize data to ETAP projects
• User-definable frequency range • Voltage drop & loss consideration • Perform consistency checks during
• Resonance condition identification & alerting • Class 1E DC power & control system models data exchange
• User-customizable plots • Simulation of control system with battery • Substitute missing information with ETAP
discharge voltage defaults & library data
Harmonic Filters • Duty cycle diversity factor
• Filter design & sizing • Load model type per operating characteristics Project Merge
• Single-tuned, high-pass, & band-pass filters • Battery duty cycle calculated from • Parallel ETAP project development
• Automatic filter overloading alert individual loads • Merge Base & Revision Data
• Interharmonic filter modeling • Options for battery & load duty cycle 1 • Merge TCCs Views
minute span • Multi-user management of project merge
• Multiple user selected options for battery
characteristic interpolation SmartPlant® Electrical Interface
• Multiple diversity & correction factors • Bi-directional data exchange
• Battery sizing report in IEEE 485 • Map attributes of SPEL with ETAP elements
Standard format • Database mapping via graphic user interface
• Plot battery capacity, voltage, & current
• Plot bus voltage & load & branch flow e-DPP® Interface
• Map attributes of e-DPP to ETAP elements
Transformer • Detailed battery library
• Synchronize e-DPP data to ETAP projects
MVA Sizing • Database mapping via graphic user interface
• Sizing based on connected or operating load
• ANSI & IEC standard types, classes, & ratings
• Considers ambient temperature, altitude, load
growth, & load factors
• MVA Sizing based on cooling stages

Tap Optimization
• ANSI / IEEE C57.116 Standard
• Optimize unit transformer turns ratio
• Considers system voltage variation
• Considers generation station auxiliary load
• Generator reactive capacity vs. voltage plots
Comprehensive

Distribution Systems Geographic Information Transmission Line


Unbalanced Load Flow System Line Constants
• Unbalanced power flow GIS Map • Conductor & ground wire libraries
• Single-phase & unbalanced 3-phase modeling • View GIS maps in ETAP • Built-in configurations: horizontal, vertical, etc.
• Unbalanced & nonlinear load modeling • Display analysis results on GIS maps • General configuration: X, Y, & Z coordinates
• Open-delta transformer modeling • Synchronize GIS data to ETAP projects • Multi-line mutual coupling
• Center-tap transformer modeling • Use graphical user interface for data mapping • Phase & sequence impedance matrix
• Three 1-phase transformer modeling • Control modification & accept / reject actions • Transposed & un-transposed lines
• Isolated sub-systems with voltage-control • Check consistency for data synchronization • Short & long line models
source modeling • Multiple layer soil model
• Utilize GIS map tools
• Isolated 1-phase source & system modeling • Calculated or user-defined impedances
• GIS handling of 1-phase systems
• Series fault or open phase condition modeling
• Phase & sequence voltage, current, & power Line Ampacity
• Voltage & current unbalance factors • Conductor ampacity vs. temperature
• Transmission line coupling • IEEE 738 Standard
• Automatic device evaluation • Determine maximum operating temperature
• Report voltage & power in multi-units for various loading conditions
• Derated ampacity based on temperature limit
Optimal Power Flow • Consider weather, solar heat, &
• Solve multiple objectives simultaneously geographical location
• Interior point method with barrier functions Ground Grid Systems Sag & Tension
• Minimize power losses
Finite Element Method • Sag / tension vs. temperature
• Active power optimization
• 3-D plots for step, touch, & absolute potentials • Multiple spans between dead-end structures
• Reactive power optimization
• 3-D irregular configurations • Level spans of unequal length
• Optimal dispatch
• 3-D graphical interface views • Solve spans of unequal length on different
Optimal Capacitor Placement • Rods & conductors in any direction horizontal planes
• Optimal location & bank size • Graphical display of over limits • Include effects of wind, temperature, & k factor
• Minimize installation & operation costs
• Individual source or average energy cost IEEE 80 & 665 Standards HVDC Transmission Link
• Conductor & rod optimization • Detailed rectifier & converter modeling
• Voltage & power factor objectives
• 3-D graphical interface views • Composite AC / DC & DC / AC systems
• Minimum, maximum, & average loading
• Built-in control schemes
• Branch capacity release & cost savings
• Inclusive transformer model
• Review capacitor impact on the system
• Automatic harmonic spectrum calculation
• Capacitor control method
• Easy-to-use integrated model
• Flexible constraints

Reliability Assessment
• System reliability
• Customer oriented indices
• Energy (cost) indices
• Sensitivity analysis
• Single & double contingency

Single-Phase Distribution ETAP Quality Assurance


• ANSI & IEC Standards ETAP's quality assurance is specifically dedicated to meeting the requirements of:
• Load flow with graphical per phase display
• Voltage drop & power losses ISO 9001:2008 ETAP is Verified and Validated (V&V) against field results, real system
measurements, established programs, and hand calculations in order
• Voltage & current unbalance factors 10 CFR 50 Appendix B to ensure its technical accuracy. Each release of ETAP undergoes a
• Automatic device duty evaluation & alerts 10 CFR Part 21 complete V&V process using thousands of test cases for each and
10 CFR Part 50.55 every calculation module and library data.
ANSI/ASME N45.2 Registered to ISO 9001:2008
ASME NQA-1
ANSI / IEEE 730.1
CAN / CSA-Q396.1.2
ANSI N45.2.2 Certificate No. 10002889 QM08
ETAP is a high impact software qualified for use within nuclear, military and mission
critical facilities and operations.
ETAP Real-Time
ETAP Real-Time technology allows you to, predict, control, visualize, optimize, summarize and automate
your power system. Distributed and web-based technologies provide the tools to make informative
decisions based on planned or unplanned events from any location.

Monitoring & Predictive Simulation


Advanced Monitoring Distributed Electrical SCADA Waveform Capture &
• Network Topology Builder & Processor • Integrated SCADA functionality Synchrophasor Measuremens
• Intelligent graphical user interface • Smart Grid & Microgrid Master Controllers • Automatic download of waveform captures
• State estimator & load distributor • Real-Time decision making applications • Automatic Archive
• Process & performance monitoring • Predictive Simulation, Optimization & • Waveform Capture Viewer
• Alarm & notification management Automation • Transfer data to DPET module for tuning
• Generation reserve monitoring • Operator training simulator • Replay recorded waveforms for root cause &
• Multi-state breaker monitoring & control • Online & archive data trending effect analysis
• Web-based SCADA architecture • Capture data from Disturbance Monitoring
Energy Accounting • Open connectivity simplifies integration Equipment
• Energy tariff builder with business & information systems • COMTRADE Sequence-of-Events Recorders
• Customizable reports • Built-in server redundancy platform & PMUs
• Real-time energy cost tracker • Integrated historian for both data & events • Fault & Dynamic Disturbance Recorders
• Cost & consumption summary • Integrated alarm & event management • Online & archive trending
• Wide array of standard drivers
Real-Time Simulation

• Simulate circuit breaker operation

• Identify potential operating problems

• Simulate motor starting & load change

• Predict operating time of protective devices

• Predict system response based on operator
actions
• Perform “What If” operating scenarios
• Web-based simulation & alerts
• Simulate real-time & archived data
• Operator assistance & training
Thin Client Consoles IEC 61850 Substation Automation
Event Playback • Thin client based monitoring & control • Direct IEC 61850 connectivity from
• Replay archived historian data • Human Machine Interface (HMI) ETAP Server
• Investigate cause & effect template library • IEC 61850 environmental compliant
• Explore alternative actions • Automatically generate electrical gateway for distributed control &
• Replay “What If” scenarios diagrams from ETAP data collection
• Playback of event views • Intelligent web graphical user interface • Automatic download of ICD &
• Historical alarm database • Geospatial maps for situational awareness CID configuration files
• Configurable web interface & control • Automation logic
Load Forecasting • Alarm & warning displays
• Adaptive bus load forecasting System Communications
• Customizable trending
• Real-time trending • Wide array of standard drivers
• Flexibility to create “what if” scenarios
• Load profile library • Automatic download of COMTRADE
• Execution of ETAP scenarios remotelys
• Forecasting scenario archiving & SOE files

• Direct Modbus RTU and TCP communication

• Direct DNP3 read\write communication
• Integrated historian for both data & events
• Integrated alarm & event management




Native SCADA Protocols
• IEC 61850 • OPC
Web Real-Time Consoles
• Safe & Secure communication • Modbus • OPC UA
• User and machine Access Management
• DNP3
• Perform “what if” simulations remotely
• Customizable views Direct connectivity to any industry compliant system.
• Rich Silverlight views
Power Management System

Energy Management System IntelligentSubstation Intelligent Load Shedding


Automatic Generation Control Substation Automation Load Preservation
• Multi-area control • Flexible automation • Steady-state & transient response
• Load frequency control • Programmable logic editor • Optimal load preservation
• MW & MVAR sharing • Online control • Fast response time
• NERC performance standard • Remote control - enable & disable commands • Reliable operation
• Control inhibition based on system operational • Minimum load shedding
Economic Dispatch constraints • Proactive contingency analysis
• Minimize fuel costs • System islanding logic
• Optimize energy costs Switching Management • VFD load reduction control
• Fast solution • Switching sequence management
• Robust algorithms • Safety & security procedures System Restoration
• Interlock logic evaluator • Restart inhibition
Supervisory Control • Switching plan validation • Logical load sequencer
• System optimization • Control inhibition based on switching • Load / source restoration priority
• Supervisory & advisory control system operations
• Optimal power flow • Safety ground switch Load Shedding Validation
• Programmable logic editor • Pre-switch & post-action interlock • Automatic generation of
• Enforced interlock logic in simulation mode transient study cases
Interchange Scheduling • Confirm load shedding actions
• Integrated operation with Switching
• Tariff analyzer • Simulate ILS recommendation
Management System
• Rate structure builder • Integrated stability knowledge base
• Supervisory control for real-time switching
• Transaction scheduling
operation
• Transaction contract
• Transaction reports Load Management
• Fuel cost schedule reports • Demand-side management
• Time-of-use load shifting
Reserve Management
• Intelligent load management
• Operating reserve analysis
• Reserve capacity monitoring
• Notification of inadequate reserve
• Predict operating reserve

Information Storage & Retrieval Faster Than Real-Time™ Solutions


• SQL Server-based data archiving
• Energy, power & non-electrical data tracking • Power Management System
• Automatic data handling
• Export to MS Excel • Energy Management System
• Customizable Reports
• Generation Management System
• Distribution Mangement System
• Intelligent Load Shedding
• Smart Grid & Microgrid Solutions

(800) 477-ETAP • (949) 900-1000