Power System Modeling etap 18
®
• Study result & alert animation • Ribbon bar for Ground Grid & Cable Pulling New
• Automatic incremental updates • Windows Active Directory authentication New
3 etap.com
etap 18
®
Elements New
• Series Capacitor
–– User-selectable capacitor location
–– Calculate degree of compensation
–– Consider MOV protection & bypass
• Switched Capacitor
–– Automatic control modes: voltage, current,
power factor
–– Control buses & branches
• Distribution Voltage Regulator
–– Automatic control modes: forward, reverse Rule Book - Harmonic Compliance Limits New
–– Include Line Drop Compensation (LDC) • ANSI/IEEE 519-2014
–– Control based on load side voltage requirements • User-defined grid code & local standards
• Wind Turbine Generator • Over 450 new V&V protective device models
Equipment Warehouse
• Overhead line – phase, ground, tower/pole
• Overhead catenary
• Power cables
• Distribution transformer
• Low-voltage circuit breakers
• Power fuses
• Railway track
• Equipment reliability
etap.com 4
Data Collection & Synchronization App - etapAPP™ New etap 18
®
Composites Components
Nested one-line diagram View, edit & verify data
using composite networks using property data grid
views
5 etap.com
etap 18
®
Motor Starting
• Enhanced inverter model
• Plot Manager interface New
Short Circuit
• Compliance with IEC 60909-2016 Ed. 2.0 New
• Variable fault current vs. voltage
• LV to EHV system fault current calculation
etap.com 6
Arc Flash Analysis etap 18
®
7 etap.com
etap 18
®
etap.com 8
Renewable & Microgrid etap 18
®
Type 3
Transient Stability
Type 4
• Line-to-line fault event simulation
• Line-to-line-to-ground fault event simulation
• Improved synchronous machine saturation model
• Enhanced built-in excitation systems
Microgrid Modeling
• Enhanced frequency-dependent network &
• Transient Stability (TS) to User-Defined Dynamic Model generator modeling
(UDM) network control signal types
• Microgrid Controller network parameter inputs
• Internal or external inputs from: to UDM New
–– Power system stability network • Improved inverter transient response
–– Real-time input measurements or tags • Enhanced UDM model library
• TS voltage & power flows from network can be • Plot Manager interface New
accessed by UDM Microgrid Controller
• User-defined renewable energy models for Wind
Turbine Generator & Photovoltaic Array New
9 etap.com
etap 18
®
• Substation & Traction transformers –– Rail energy consumption including maximum, peak &
average rolling demand
–– Auto-transformer
–– Trip profiles - acceleration, speed, elevation, etc.
–– Booster-transformer
–– Substation power flows & voltages
–– Scott-T transformer
–– Train power flows & voltages per route
• Signal, Speed Limit, Level Crossing
–– Rail voltage, track potential
• Distance, Elevation & Bend Radius
• Alerts based on EN 50163 & EN 50329 standards
AC DC
etap.com 10
Power System Monitoring & Control - ETAP Real-Time™ etap 18
®
Load Preservation
SCADA System & Architecture • Steady-state & transient response
• MCC / BCC redundancy with disaster recovery • Fast response time (10ms) with secured communication
• Encryption & authentication security • Priority optimization based on number of
• Self-healing strategies trips per time period
• Integrated front-end processor with native
communication drivers Switching Order Management New
• Web services communication • Mobile interface
• Automatic historical data replication • Crew assignment & field confirmation of actions
• Native IEC 60870 protocol New • Scheduled & active order viewer
11 etap.com
etap.com
Follow us:
Visit etap.com to view the current events schedule. Events are added throughout the year, so be sure to visit frequently for the latest updates.