USG SHEETROCK® BRAND


TUFF-HIDE ™

PRIMER-SURFACER
Skim coats and primes in one spray application
• Achieves a Level 5 finish faster
• High build spray for a smoother, more beautiful finish
• Durable coating hides minor surface defects
• Excellent for critical light areas
• Ideal finish for ceilings
• Dries white; can be tinted to match final top coat
• For professional use only

DESCRIPTION USG Sheetrock® Brand Tuff-Hide™ Primer-Surfacer is the original dual-purpose vinyl acrylic
latex-based coating designed for interior application over new drywall. For a GA-214/ASTM C840
Level 5 gypsum board finish, a single spray application provides the same highest quality drywall
finish as the traditional two-step process of skim-coating surfaces with joint compound followed
by a coat of primer.

In ceiling applications where a flat white finish is desired, USG Sheetrock® Brand Tuff-Hide™ Primer-
Surfacer can be left unpainted, providing an ideal final finish.

Traditional Level 5 Finish USG Sheetrock® Brand Tuff -Hide™ Primer-Surfacer


Level 5 Finish

USG Sheetrock® Brand L5 – USG Sheetrock® Brand


L5 First Coat™ Primer Tuff-Hide™ Primer-Surfacer

Skim coat

L4 – Finish coat L4 – Finish coat

L3 – Fill coat L3 – Fill coat

L2 – Embed coat L2 – Embed coat

L1 – Tape (fire taping) L1 – Tape (fire taping)

DIRECTIONS Substrate must be sound, dry, clean and free of oil, grease, mildew and dust. Product, air and
SURFACE PREPARATION surface temperatures must be maintained at a minimum of 55°F (13°C) throughout the finishing
process. Refer to Finishing
Traditional Level 5and Decorating Gypsum Panels Installation Guide (J2010) for finishing
Finish
and decorating best practices.
TUFF-HIDE™ Level 5 Finish

New Drywall: Treat all joints, fasteners and accessories with a recommended USG Sheetrock®
Brand joint treatment system. Fill all nicks, voids and gouges with joint compound. A minimum
Level 4 wallboard finish is recommended. Refer to Gypsum Association publication Recommended
Levels of Gypsum Board Finish (GA-214) or ASTM C840 equivalent for a detailed description.
Level 5 finish can only been achieved if applied to Level 4 finished wallboard.

Concrete & Plaster: Concrete and plaster surfaces should be thoroughly dry before painting.
Concrete surfaces should age at least 60 days before finishing. Remove all form oils and
efflorescence and grind down form lines. Fill cracks and holes, and level concrete surfaces
with USG Sheetrock® Brand Durabond® Setting-Type Joint Compound, USG Sheetrock® Brand
Easy Sand™ Lightweight Setting-Type Joint Compound or USG Sheetrock® Brand Cover Coat®
Compound and let dry.
MIXING Stir gently. Use fresh material. Do not thin. Thinning will reduce performance. Do not intermix with
any other product. May be tinted with up to 2 oz. per gal. of universal colorants.

APPLICATION Airless spray application only. Use professional equipment that meets or exceeds the following
rating when spraying through 50 ft. of 1/4" I.D. high-pressure hose: output at least 1 gal. per
minute; pump pressure rated at 2,700-3,000 psi; and accommodates a 0.031" spray tip at 2,000 psi
(Graco Mark V™ or equivalent). Use a 30-mesh filter located in the high-pressure manifold. Use a
spray-tip orifice between 0.023" to 0.031". It is recommended to use a Graco heavy-duty texture
spray gun or equivalent that accommodates a Graco Reverse-A-Clean (RAC) SwitchTip.

Test the spray pattern prior to application. To apply, hold spray gun perpendicular to the surface
approximately 18" away. Move the gun parallel to the surface at a steady rate. Overlap preceding
application by 1/2 of the fan width for uniform paint thickness. Spray from left to right to scratch
in the initial coat at approximately half of the desired thickness. Then crosshatch spray up and
down as the double-up coat to the desired thickness. When painting corners, aim the gun toward
the center of the corner to ensure both sides are sprayed evenly. When used in lieu of a skim coat
of joint compound and paint primer coat in a Level 5 gypsum board finish, apply to a minimum
Wet Film Thickness (WFT) of 15 mils. In all applications, a wet film thickness in excess of 20 mils is
not recommended. During and after application, avoid drafts and maintain 55°F (13°C) minimum
product, air and surface temperatures until surface is dry.

Note: May be roller applied for use as a high-solids, primer paint coat. Use a high-quality roller, with 1/4"- 3/8" nap roller cover on
smooth surfaces. Apply to a wet film thickness (WFT) of 5-10 mils.

DRYING TIME Dries to touch in approximately 60-90 minutes when applied at 15-20 mils WFT (9-12 mils DFT)
under normal drying conditions (77°F/50% RH). Let dry before recoating. The following (together
or individually) will slow drying and/or greatly impact the finished appearance: high humidity, cold
temperature and poor ventilation/air circulation.

COVERAGE Approximately 100-125 sq. ft. per gallon when applied at 15-20 mils WFT (9-12 mils DFT). Actual
coverage can vary depending on factors such as substrate surface condition, spray techniques,
procedures, coating uniformity and thickness.

CLEANUP Wipe up drips and spills immediately with damp cloth. Clean tools with warm, soapy water. Close
container after each use.

SANDING If proper spraying technique is used, sanding probably will not be needed. However, if touch-up
sanding is required, this formulation sands easily.

DECORATING May be painted after overnight drying. Follow paint manufacturer’s instructions. May be left
unpainted.

PRODUCT DATA Testing: Tested for abrasion resistance, passing 1,000 cycles, in accordance with ASTM D4977
(modified). For additional information on abrasion resistance testing methods and comparative
results, refer to Abuse-Resistant Systems (SA929). Tested in accordance with ASTM D3450
(washability) and ASTM D2486 (scrubbability).
Material: Vinyl acrylic latex-based.
Types: Spray application only.
Temperature Sensitivity: Store in a dry location. Protect from freezing, exposure to extreme heat
and direct sunlight.
VOC Content: 22 g/L.
Coverage: Approximately 100-125 sq. ft. per gallon when applied at 15-20 mils WFT (9-12 mils DFT).
Drying Time: Approximately 60-90 minutes when applied at 15-20 mils WFT (9-12 mils DFT) under
normal drying conditions (77°F/50% RH).
Storage: Store at room temperature in a dry location. Up to 12-month shelf life under good
storage conditions.
Packaging: 5 gal. pail, 50 gal. drum.
SUBMITTAL APPROVALS Job Name

Contractor Date

PRODUCT INFORMATION
See usg.com for the most up-to-date product information.

WARNING
Mist, vapors and/or dust may cause irritation to eyes, skin,
nose, throat and upper respiratory tract. Avoid irritation
by reducing exposure to mist, vapors and/or dust. Use in a
well-ventilated area or provide sufficient local ventilation.
If misty/high vapor levels/dusty, wear a NIOSH/MSHA-
approved mist, vapor or dust respirator. Long-term
breathing of respirable crystalline silica dust can cause
permanent lung damage and/or cancer. Prolonged and
repeated breathing of respirable mica dust may cause lung
disease (pneumoconiosis). Wear eye protection. If eye
contact occurs, flush thoroughly with water for 15 minutes.
If irritation persists, call a physician. Wash with soap and
water after use. Do not ingest. If ingested, call a physician.
Do not use if material has spoiled, i.e., there is a moldy
appearance or an unpleasant odor. Close container and
discard properly.
For more information, call Product Safety: 800 507-8899
or see the SDS at usg.com.
KEEP OUT OF REACH OF CHILDREN.

TRADEMARKS
The trademarks USG, COVER COAT, DURABOND, EASY
SAND, FIRST COAT, SHEETROCK, TUFF-HIDE, IT'S YOUR
WORLD. BUILD IT., the USG logo, the design elements
and colors, and related marks are trademarks of USG
Corporation or its affiliates.

The trademarks Mark V and related marks are trademarks of


Graco Inc. or its affiliates.

NOTE
Products described here may not be available in all
geographic markets. Consult your USG Company sales
office or representative for information.

NOTICE
We shall not be liable for incidental and consequential
damages, directly or indirectly sustained, nor for any loss
caused by application of these goods not in accordance with
current printed instructions or for other than the intended
use. For most current information, visit usg.com. Our liability
is expressly limited to replacement of defective goods. Any
claim shall be deemed waived unless made in writing to
us within thirty (30) days from date it was or reasonably
should have been discovered. 800 USG.4YOU
800 (874-4968)
SAFETY FIRST!
usg.com
Follow good safety and industrial hygiene practices during
handling and installing all products and systems. Take
necessary precautions and wear the appropriate personal Manufactured by J1613/rev. 10-15
protective equipment as needed. Read Safety Data Sheets United States Gypsum Company © 2015 USG Corporation and/or
and related literature on products before specification and/ 550 West Adams Street its affiliates. All rights reserved.
or installation. Chicago, IL 60661 Printed in U.S.A.