You are on page 1of 2

Gas Detection Control Unit ET-1D

in Wall Mounted Housing, 24 V DC


Article-No.: 303004

Description : Gas Detection Control Unit for detection and measurement of flam-
mable and / or toxic gases as well as oxygen. Graphic display. 2
alarm levels. 2 alarm, horn and fault relays.
Features
Number of Transmitters : 1
Signal Processing : Microcontroller with A/D-Converter
Alarm / Fault / Indication: : ƒ illuminated 4-lined display for indication of measured, messages
and alarms, bar graph indication of concentration
ƒ 1 green operation LED
ƒ 2 red alarm LEDs (alarm levels 1 and 2)
ƒ 1 yellow LED for indication of device and transmitter fault
Alarm Levels : 2 freely adjustable alarm levels per channel,
latching configurable
Relays : 4 change-over contacts 230 V / 200 mA for alarm 1 and 2, fault,
horn
Additional Functions : ƒ completely configurable at the control unit via 4 keys
ƒ RS 232/RS 485 interface for communication with external Pe-
riphery (PC or PLT-System)
ƒ Alarm locking in maintenance mode
ƒ Horn alarm separately reset able
Operation Temperature : -10 °C to +40 °C
Mechanical Features
Dimensions : 194 mm x 160 mm x 90 mm (Height x Width x Depth)
Installation : Wall mounted housing
Material : Housing ABS
Enclosure Rating : IP 54
Storage Temperature : -25 °C to +60 °C
Electrical Features
Power Supply : 24 V DC
Power Consumption : Max. 0.8 A / 20 W
Cable Gland : ▪ 1 x M20 x 1.5 (diameter of cable 7-13 mm)
▪ 5 x M16 x 1.5 (diameter of cable 5-10 mm)
Conformity
EC-Directives : Y ¯ II (3)G
94/9/EC (ATEX), 89/336/EEC (EMC), 73/23/EEC (LVD)
Measuring Function : Designed according to
ƒ EN 61779-1 to EN 61779-4
ƒ EN 45544-1 to EN 45544-3
ƒ EN 50104

ExTox GmbH ● Hildebrandstraße 5 ● D-44319 Dortmund ● Tel. +49 231 589 409-0 ● Fax +49 231 589 409-10
Internet: www.extox.de ● mail to: info@extox.de

303004_ET-1D_Wandaufbau_24V_e_V1.doc,20/04/2005Seite 1 von 2
Gas Detection Control Unit ET-1D
in Wall Mounted Housing, 24 V DC
Article-No.: 303004

Drawing

90mm 160 mm
Boreholes: 146 mm

Gasmess-Systeme GmbH
ET-1D

Boreholes: 146 mm
160 mm

194 mm
F1 F2 F3 F4

ExTox Gasmess-Systeme GmbH Tel. +49 (0)231/589409-0 www.extox.de

Installation : ▪ Position of boreholes used for wall mounting is marked red in the draw-
ing.
▪ Maximum diameter of mounting screws: d= 4.5 mm
▪ The housing can be opened for installation and maintenance purposes.
The cover can now be opened and tucked up. Provide free space above
the housing.
Connection Scheme

Alarm 1 Fault
Iout - Analogue output
Iout + (only ET-1DA)
Fuse:
160 mA, tr

+24V Power Supply


Close
Open
Common

Interface
4 - 20 mA Signal

RS 485-
Ground GND
Shielding

Alarm 2 Maintenance
A
B

L N PE + -
Power supply Transmitter
Open
Common
Close

230 V AC or 24 V DC
depending on type
Ground GND

A Interface
B RS 485-
+ 24 V
+ input 1
- Digital
+ input 2
- Digital

L L L N N N PE PE PE PE PE PE
for external devices
(horn,flashing lights)

This Data Sheet is at the same time a type specific supplement


to the Instruction Manual ExTox Gas Detection Control Unit Series ET-1D.
(Subject to technical changes)

ExTox GmbH ● Hildebrandstraße 5 ● D-44319 Dortmund ● Tel. +49 231 589 409-0 ● Fax +49 231 589 409-10
Internet: www.extox.de ● mail to: info@extox.de

303004_ET-1D_Wandaufbau_24V_e_V1.doc,20/04/2005Seite 2 von 2