Professional Documents
Culture Documents
4 2 1 1
A521 A511 A524 A510
3256
A563
2 FIRE
ELEVATOR
B1-C1 P1 9 m² COLLECTION AREA 1.5 X 2M A552
REVISION
A510 DEPARTMENT 2600
2189 3256 8137 B1-1-ST3 DN
CONNECTION NO. DATE DESCRIPTION
B1-G
375
1 10/01/2018 Issued for Review
B1-1.10B
790
21149 FURRING TO BRACING AT HEIGHT 21572 2 24/01/2018 Issued for Design Development
P1
P1
MECHANICAL LOUVER
@2213mm above level
600 x 450 mm ± 1127.70 ± 1128.10 3 28/02/2018 Issued for Review
EW5
P1C P4a CONC-2
B1.2
RETAIL AND
5 638 500
EW9
EW9 4 01/05/2018 Issued for Building Permit
B1-1.2A A621
EW9.2
5 13/06/2018 Building Permit Revisions
4521
4521
CONSUMER P1 P1 P16a P1 OVERHEAD SIGNAGE
SUPPLEMENT STORE
4620
3315
SERVICES PR-1 500 CONC-2 6 30/07/2018 Building Permit Revisions 2
10 B1-1.10A B1-1.11 Refer to signage drawings
6458
618
A620 P1 FD-1 PR-1 PARKING BELOW 8 14/08/2018 Building Permit Revisions 3
1
BACK
255
6281
EXTENT OF P16
057 9 31/08/2018 Tender Addendum #02
E
A511 ADO B1-1.2B
RTY LIN
450
3M SET
10 24/09/2018 Tender Addendum #06
A411/ 1
ADO EW9.2
3130
2500
213
11 28/02/2019 Building Permit Revisions
320
EW9.2 GREASE
INSULATION TO EXTEND EXTENT OF INSULATION AT VOID BELOW MECHANICAL LOUVER
1035
B1-1.3B 12 07/05/2019 Issued for Construction
3.4%
@2155mm above level STORAGE
PROPE
DRAINAGE CONTINUES
100
SLAB SHOWN IDINCATIVELY 609 x 455 mm EW9
BELOW SIDEWALK TO VOID BELOW B1-1.12 ± 1131.92 4605
RWL CRASH RAIL
629
B1-H EW9.2
7000
4521
4521
5690 B1-1.3A CONC-2 ± 1131.92
4685
UP 9848 8041
1881
± 1132.67 EDGE OF ROOF 100 X 100MM STEEL WALL
TYPE 4 - CLOSED CANOPY ON PR-1 P1 4 ABOVE STEEL OUTDOOR RADON MONITORING PIT PROTECTION TO ALL EXTERIOR
56 605
COLUMNS AT 5.6m HEIGHT A621 STAIR CORNERS
EW9
1
44
REFUSE HOLDING BUILDING B1
ADO A560 -2 No. 4 cubic yard containers for
6400
714 816
B1-1.4B
LOADING PLATFORM -2 No. 4 cubic yard containers for
A511 REFUSE COLLECTION AREA recyclables
CONC-2
B1.4 -3 organic bins (minimum)
RESTAURANT: FOOD B1.4
4685
SIGNAGE B1-1.4A
RESTAURANT: FOOD
2385
SERVICE ONLY - PR-1
5050
5050
200
1881
4585 2631
MEDIUM SERVICE ONLY - 542 7519
2810 MEDIUM RETAINING WALL
2600
2770
52 m² LOADING SPACE FOR HSU VEHICLE
B1-I EW5 52 m² P1 HEIGHT VARIES
704 620
100
DEMISING WALLS SUBJECT TO CHANGE ARTWORK FIXED TO RETAINING WALL.
DRAINAGE CONTINUES RWL ADO TO SUIT FUTURE TENANT (TYP.) REFER TO A400 SERIES ELEVATIONS
BELOW SIDEWALK ADO
LIGHT STANDARD 2355 11500
A420/ 1
Refer to lighting drawings
450 2175
2440 WIDE DOUBLE DOOR IN METAL GUARDS
590
CONC-2 B1-1.5B A411/ 3 1.5m UTILITIES EASEMENT LINE
FOR LOADING/ GARBAGE PICK-UP.
B1.5 B1.5 TO BE SECURED TO FLOOR WHEN CLOSED. PLAN 161 2948
6400
± 1132.67
EW9
SERVICE ONLY - SERVICE ONLY -
4980
4980
SIDE RAILS WHILE OPEN DURING OPERATION
MEDIUM MEDIUM
51 m² 52 m² DOCK BUMPER
B1-J
228
BOLLARDS AT B1-1.6B
EQ
915mm IN HEIGHT
VESTIBULE BY
EQ
TENANT
EQ
44008
CONC-2
A410/ 2
1.1m GUARD RAIL (PAINTED METAL) LOADING AREA
EQ
1613
5600
5600
6400
399
MAX SLOPE 4%
5.5%
PR-1
EQ
CANOPIES AT 3.m
HEIGHT
EQ
B1.6
LIQUOR STORE
EQ
12800
12800
1160 538 724
EW-10
B1-K
12192
264 m²
± 1132.67 14 CROSS BRACING
THIS DRAWING IS “ISSUED FOR CONSTRUCTION” AND IS
EQ
4997
EQ
EQ
TENANT
A520 6 PROMPTLY BRING IT TO THE ATTENTION OF THE CONSULTANT.
EQ
SLIDING DOOR
777 2070 846 3 FLOOR AREAS WHERE SHOWN ON PLAN DRAWINGS REFER TO
438 537 1160
EW-10
1677
B1-1.7C
Plan 1612946; Block 3; Lot 4
2% SLOPE CLIENT:
CONC-2 RESTAURANT: 3 Trinity Development
1677
5030
1960
MEDIUM
Toronto, ON, M8X 2X9
STEEL OUTDOOR STAIR ROAD GRADING MAXIMUM 6%
1677
T/416.255.8800 F/416.255.8355
Refer to civil drawings
543 ARCHITECT OF RECORD:
UP
± 1131.51 B+H Architects
938 355
P3 1500
TYPE 1 - OPEN, ROD CANOPY 13 481 University Avenue, Suite 300
12047
FLOORS WALLS
4830
1600
5080
VESTIBULE BY
A521 TENANT 138 m²
CEILINGS AS NOTED ON PLANS. CODE CONSULTANT: TRAFFIC CONSULTANT :
743
5079 997 790 3495 460 4660 CEILING FINISH FOR ALL MECHANICAL AND ELECTRICAL ROOMS TO BE EXPOSED Morrison Hershfeld Bunt & Associates
EQ
STEEL DECK U.O.N. 125 Commerce Valley Drive West, 11012 Macleod Trail SE, Suite 400
752 918
1599
EW9
1932 1165 1164 1165 EQ EQ EQ EQ
EQ
270
ADO
CONCRETE BOLLARDS (3)
1 4 401-3901 Highway 7,
Vaughan, ON, L4L8L5
EW12 EW6 A524 ADDITIONAL SUPPORT TO BE A523 T/905.850.4400
EW12 PROVIDED WITHIN PARTITIONS LANDSCAPE AND CIVIL CONSULTANT :
B1-3A B1-4 AS REQUIRED FOR LADDER
12 8 Urban Systems
2716 Sunridge Way NE, Suite 600
A621 1384 P1
A621 Calgary, AB, T1Y 0A5
TYPE 1 - OPEN, ROD CANOPY AT 3.6m T/403.291.1193
HEIGHT A411/ 2
GEOTECHNICAL CONSULTANT :
B1-G B1-1.10B Macintosh Lalani Engineering Ltd.
4604 13th Street NE, Bay 10
Calgary, AB, T2E 6P1
T/403.291.2345 F/403.291.2356
ELECTRICAL CONSULTANT :
LIGHT STANDARD RETAIL AND
Refer to lighting drawings SERVICE CORRIDOR Hammerschlag + Joffe Inc.
CONSUMER 69 Lesmill Road
SERVICES Toronto, ON, M3B 2T8
CONC-3 B1 SPRINKLER ROOM CONC-3 T/416.444.9263 F/416.444.1463
P1 MECHANICAL CONSULTANT :
P1
PT-1 PT-1
The Mitchell Partnership Inc.
285 Yorkland Blvd.
P16a P16a P1 Toronto, Ontario, M2J 1S5
T/416.499.8000 F/416.499.7446
OIL GRIT SEPARATOR
B1-1.10A B1-1.11 FIRE PROTECTION
Novus Fire Protection
P16a 110 Woodbine Downs Blvd. Unit 4B
UTILITIES EASEMENT
P16a Toronto, Ontario M9W 5S6
T/416 746-2590
CABLE PULLBOX 1
A511 EW9.2 PROJECT :
B1-1.2B
B1-1.12
EW9.2
REFUSE HOLDING B1
CONC-3
B1-1.3B
PT-1
P16a
270
EW9.2
B1-H
EW9
Site B, Trinity Hills
EW9 EDGE OF ROOF
ABOVE Mixed-Use Development
Block B - Trinity Hills
SHEET CONTENTS :
BUILDING B1 (SOUTH) FLOOR PLAN
A221
5/7/2019 11:25:56 AM
B2
B4
B1
B3