Refer to "Error Diagnosis Using the Alarm Displays"(P.11-11) for appropriate alarm measures.
Release the alarm using one of the following methods. Remove the cause of the alarm first.
· Input the alarm reset input (RESET) signal.
· Turn OFF the power supply, then turn it ON again.
· Execute the alarm reset on the Parameter Unit.
However, some alarms can only be reset by turning the power supply OFF then ON again. Refer
to the next item "Alarm List".
If you release an alarm while the operation command (RUN) is turned ON, the Servo Drive will
start operation as soon as the alarm is released, which is dangerous. Be sure to turn OFF the RUN
before clearing the alarm.
If the RUN is always ON, first check safety sufficiently before clearing the alarm.
When an alarm occurs, the servodrive latches the status of the servodrive just before the alarm
occurence. Those latched values can be read with the software tool for diagnostics. Refer to the
CX-Drive for details.
The stop mode in case of an alarm may vary depending on the „Immediate stop“ attribute in each
alarm.