voltage is low. · Check the power · Momentary power supply capacity. interruption occurred. · Change the power · Power supply capacity Occurs when the servo is supply. is insufficient. turned ON. · Turn ON the power · The power supply voltage supply. is reduced because the · Extend the Momentary main power supply is OFF. Hold Time (Pn509). Main circuit power · The main power supply 13 supply undervoltage is not input.
· Correctly connect the phases
of the power supply voltage. · Phase loss · Correctly connect the Occurs when the power single-phase. supply is turned ON. · The main circuit power supply is damaged. · Replace the driver. · Control PCB damage.
· Control PCB error · Replace the driver.
· Repair the short-circuited or
· The motor power line is ground-faulted power line. short-circuited or · Measure the insulation ground-faulted resistance at the motor between phases. and, if there is a short circuit, replace the motor.
· Phase U, phase V, phase
W, and the ground are · Wire correctly. wired incorrectly.
· Measure the winding
· Motor winding is resistance, and if the burned out. winding is burned out, replace the motor.
11 · Do not frequently input
the operation Occurs when the servo is · The relay for the 14 Overcurrent command (RUN) input. turned ON. dynamic brake has · Do not operate the been deposited. system by turning the Error and Maintenance
servo ON and OFF.
· Use a motor that is
· Motor non-conformity appropriate for use with the driver.
· Wait at least 100 ms before
· The pulse input timing inputting pulses after is too soon. turning ON the operation command (RUN).
· Reduce the ambient
temperature of the · The resistor in the driver to 55C or lower. driver is abnormally · If the relay does not overheating. click when the power supply is turned ON, replace the driver.
11-12 Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL