extinguish, restart power switch. (Voltage adjustment knob must be turned to the minimum or output voltage less than the limited 1、Summary voltage.) RXN-3020D、JPS-3020D、RXN-3030D、JPS-3030D are single output (9) Attention: Don't start power switch with the load. Otherwise, easy power supply.RXN-302D(A)-II、JPS-302D-II、MPS-3002L-3、 to damage DC Power Supply and the load. When the load current RXN-303D(A)-II、JPS-303D-II、MPS-3003L-3、RXN-305D(A)-II、 more than 10A,Please use the rear output terminal. When use large JPS-305D-II、MPS-3005L-3、RXN-3010D(A)-II、JPS-3010D-II、 current, wiring terminal and output line must tighten. Otherwise, MPS-3010L-3 are three-output power supply, collectively referred to as wiring terminal will be damaged caused by connecting the big high precision constant current, constant voltage DC Linear Power resistance leading to fever. Supply .Characterized by high precision and strong reliability. And the three-output power supply with auto tracing, auto series and parallel 4、Repair operation. 4-1 Fuse replacement: KXN-3050D、KXN-3060D、…KXN-30010D are high efficiency If fuse is burnt out, the power supply will stop working. If such constant current, constant voltage DC Switching Power Supply. This case occurs, its cause must be found and corrected. Use same type series DC Power Supply feature is strong ability to load and work for fuse replacement. Do not open the fuse box, unless problem occurs. low failure rate. Also they with the over-voltage protection, 4-2 Repair: over-temperature protection, over-load protection, over-current If the interior of the power supply is burn out, it must be repaired by protection functions.(work efficiency≥86%) professional maintenance personnel or by the manufacturer through RXN、JPS、MPS、KXN series constant voltage constant current DC the distributor. Do not repair it by yourself for the safety reason. Power Supply design for technology product development, laboratory, junior college, electronic production line and communications industry. Caution: KXN Series are Switching Power Supply. Internal The technical parameters please see the table. have high-pressure circuit. Not professional maintenance personnel must not repair, lest produce danger.
8 1
Downloaded from www.Manualslib.com manuals search engine
Table 1 RXN、JPS、MPS series 3-2 Method of operation: Model RXN-3020D RXN-3030D (1) Connect the machine to the mains supply: AC220V±10%. Parameters JPS-3020D JPS-3030D (2) Adjust over-voltage protection knob and current adjustment knob to Voltage output range 0-30V 0-30V the maximum along the clockwise direction. (3) Put power switch to the “ON”, and the red pilot lamp will go on. Current output range 0-20A 0-30A (4) Adjust voltage coarse and fine adjustment knob to the required Current & Voltage RXN series D means LED digital display value. display model PS series D means LCD digital display (5) Connect the external load to the “+” and “-”output terminal. Display precision ±1%±1word (6) When it is used to meet high requirement, the binding post of output “+”or “-”must be connected with “GND” binding post to Model RXN-302A-II RXN-303A-II RXN-305A-II RXN-3010A-II reduce the output ripple voltage. RXN-302D-II RXN-303D-II RXN-305D-II RXN-3010D-II (7) Constant current setting: First adjust the voltage to 3-10V arbitrary JPS-302D-II JPS-303D-II JPS-305D-II JPS-3010D-II value, then adjust current adjustment knob to 0(turn it to the end parameters MPS-3002L-3 MPS-3003L-3 MPS-3005L-3 MPS-3010L-3 anticlockwise).Using the line to connect the output of the positive Voltage (“+”) and the negative (“-”) electrodes. Then clockwise adjust the output 2×0-30V 2×0-30V 2×0-30V 2×0-30V current adjustment knob to the required current value. Remove the range short-circuit line, adjust voltage adjustment knob to the required voltage value, and now it is ready to be used. Current (8) Over-voltage protection setting: First adjust the over-voltage 2×0-2A 2×0-3A 2×0-5A 2×0-10A output range protection knob to the maximum along the clockwise direction. Then turn on power switch. Adjust the voltage adjustment knob to Single fixed 5V/3A the required protection value. Then anticlockwise adjust the output over-voltage protection knob to over-voltage protection. Use Current & RXN series D means LED digital display,A means pointer display. voltage must be within the scope of your limit. Otherwise it will Voltage JPS series are LCD digital display. automatically protect. Meanwhile, the over-voltage protection pilot display model MPS series are LED digital display. lamp will go on. Display Pointer display: ±2.5%. Digital display:±1%±1word Restart steps after the over-voltage protection: First turn off power precision switch. After over-voltage protection pilot lamp completely
2 7
Downloaded from www.Manualslib.com manuals search engine
2-2 Rated working condition: Table 2 KXN series Input voltage: AC 220V±10% 50/60Hz Parameters Voltage Current Current & Display Working conditions: Temperature: -10℃ to 40℃ output output Voltage precision relative humidity <90% Model range range display model Storage conditions: Temperature: -10℃ to 40℃ relative humidity <80% KXN-3050D 0-30V 0-50A LED display ±1%±1word 2-3 Constant voltage working condition: Parameter Voltage Load stability Ripple and noise KXN-3060D 0-30V 0-60A LED display ±1%±1word Model stability RXN 、JPS、MPS series ≤0.01%+2mV ≤0.01%+2mV ≤1mVrms(RMS) KXN series ≤0.2% ≤0.1% ≤0.5%P-P KXN-3080D 0-30V 0-80A LED display ±1%±1word
2-4 Constant current working condition:
Parameter Current stability Ripple and noise KXN-30100D 0-30V 0-100A LED display ±1%±1word Model RXN series ≤0.2%+3mA ≤3mArms KXN series ≤0.3% ≤0.5%P-P KXN-5050D 0-50V 0-50A LED display ±1%±1word
KXN-5060D 0-50V 0-60A LED display ±1%±1word
3、 Operating Instruction 3-1 Notice: (1) AC input: AC 220V±10% 50Hz(If input voltage is 110V±10% KXN-5080D 0-50V 0-80A LED display ±1%±1word 60Hz, on the rear of the machine will have marks) (2) Insulation: The radiator in the rear of the machine should have KXN-50100D 0-50V 0-100A LED display ±1%±1word enough space to dissipate heat.RXN-3020D、RXN-3030D and KXN Series DC Power Supply have temperature control switch. When inside temperature≥45℃radiator fan start to rotate to KXN-6030D 0-60V 0-30A LED display ±1%±1word dissipate heat. Do not use the machine in a place where the temperature is over 45℃.
6 3
Downloaded from www.Manualslib.com manuals search engine
KXN-6080D 0-60V 0-80A LED display ±1%±1word (1)Current display (I way current/voltage display) (2)Voltage display (II way current/voltage display) KXN-10010D 0-100V 0-10A LED display ±1%±1word (3)Current fine adjustment (RXN Series) (I way current adjustment) Current adjustment (KXN Series) (4)Current coarse adjustment (RXN Series) KXN-10020D 0-100V 0-20A LED display ±1%±1word Over-voltage protection adjustment (I way voltage adjustment) (KXN Series) KXN-10030D 0-100V 0-30A LED display ±1%±1word (5)Voltage fine adjustment (II way current adjustment) (6)Voltage coarse adjustment (II way voltage adjustment) KXN-20010D 0-200V 0-10A LED display ±1%±1word (7)Power switch (Power switch) (8)---------------- (I way output terminal) (9)Output terminal (II way output terminal) KXN-20020D 0-200V 0-20A LED display ±1%±1word (10) -------------- (5V/3A fixed output terminal) (11) Constant current and over-voltage (I way constant current、constant KXN-30010D 0-300V 0-10A LED display ±1%±1word protection pilot lamp voltage pilot lamp) (12) Over-temperature protection and (II way constant current、constant Constant voltage pilot lamp voltage pilot lamp) 2、Parameter specification and Panel (13)—————— (Independent /Series/Parallel switch, features LCD backlight select switch)