Item Class 1 Class 2 Class 3 General Deploy regional Selective design upgrading Robust design catering ‘standard’ technology to meet off-design conditions from early to late life flow solution accounting for or to assure higher assurance conditions with early to mid life flow performance and/or the ability to assurance conditions to availability accommodate upside and achieve minimum future volumes economic value Reservoir Designed for P50 Selective inclusion of mid-life P10 to P90 subsurface Uncertainty and production profile production chemistry risks in realizations and Chemistry without contingencies design uncertainties accounted Characteristics for system or field life for uncertainties Tight range on BfD parameters Expandability
Design Design Class
Item Class 1 Class 2 Class 3 Flexibility and No installed facility Some selected ability for Future expansion Expandability expansion capability expansion considered throughout design and capability installed Capacity Utilization
Design Design Class
Item Class 1 Class 2 Class 3 Availability No sparing, no Some sparing, some 95% to 99%. redundancy redundancy Min 75% Operability and Maintainability
Design Design Class
Item Class 1 Class 2 Class 3 Operability and No operating envelope Maintainability outside design basis Operating envelope includes Most operational “what-if” some selected off-design Significant operational scenarios designed for contingencies response required Instruments, Basic pressure, temperature and choke position Controls, and SMART Well/Field monitoring Automation