You are on page 1of 1

Structural Engineering Techniques Leeds Beckett University

Laboratory Session: Calculation and Design of Bolted Connections (version: 03/12/21)

Student name: Mine Student ID: 0000000


Please tick as appropriate (for quality assurance purposes, no mark):
Attended lab session physically: Studied online:
Summary table (10 marks)
This tables must be completed and handed in as part of the coursework submission

Table 4.1 Calculation values

1. Black bolt connection British Standard Eurocode

Shear capacity of bolts, double shear (kN) 25.12 30.144


Bearing capacity of bolts (kN) 220.8 46.1
Bearing capacity of connected parts (kN) 66.56 43.2
2. HSFG bolt connection British Standard Eurocode

Shear capacity of bolts, double shear (kN) 91.08 30.10


Bearing capacity of bolts (kN) 844.8 721.27
Bearing capacity of connected parts (kN) 45.54 29.87
Slip resistance (kN) 45.54 42.25

Table 4.2 Experimental values

Black bolt HSGF bolts HSGF bolts


Year
Average tested ultimate capacity (kN) Load at which first slip occurred (kN)

2021 114.00 180.00 45.00


2020 175.50 20.00
2019 169.60 23.00
2018 174.4 62.00
Average 114.00 174.875 37.50
Note: Please use the average values in your analysis.

You might also like