Jets™ Vacuumarator™ pump 15MB DATA SHEET NO. 2150 - 23.03.2011 Page 1 of 2 The patented Jets Vacuumarator ~ creates vacuum - macerates sewage = pumps sewage Designed for direct connection to any kind of sewage treatment plant. Outlet can also be connected to gravity piping or holding tank. Technical Data: Capacity: Flushing Capacity at 50 HZ! = Outside Dimensions: nen a Electric Motor .n.nnn Pump Casing Material: ...-.o1-nnennnnnnnnnen Rotor Housing Material... - Pump Rotor Material: Pump Knives Matetial....nmnmnnn Pump Shaft Material Connection Inlet Connection Outlet: . Total Wolghtccrcn.tcnanssanenrniai NYE oIUIT Laie] Colles _.15m3/ hr .. 180 flushes/hr verre: 214X5504288 mm. (WeLxH) sone MEZ TAA 90S2 Bronze RGS sone Stainless steel AIS! 316 Bronze RG 10 Stainless steel AIS! 420 Stainless steel AISI 316 sv B50 250 eed eteaiomeenirurtiat css ndrntnssesyeatns2 984 KG) Part No. Jets 15MD (029015003 ‘Motor control unit (031151322 Note: Changes without prior notice @ww.jetsgroup.com Myraneveten 1 6960 Harel Nerway Tal +47 700391 00, Fox +87 790391 OL. E-mall perks ne @yers Jets™ Vacuumarator™ pump 15MB DATA SHEET NO. 2150 - 23.03.2011 Page 2 of 2 Dimensions 15MB Operating Data: ‘Speed (nom, Power Connections (nom.) Power Output (nom.)... Current Consumption (230V): For other Voltages Recommended fuses. 2 1,5KW Note: Changes without prior notice www.jetsgroup.com y ee een plana seaiecs 9jETs © Connections - 15MB pump 32460-046 & VTS controller Instructions for the VTS controller are found on pages 18-26. (Actual model may deviate fram picture) VTS - controller VTS-controller The VTS-controller is the controller in the vacuum system with function as: ‘Automatic start / stop Vacuumarator Manual start / stop Vacuumarator Vacuumlevel monitoring Stop max runtime Level sensor in collecting tank ‘Automatic stop when discharging collecting tank ‘Alarm signal with system failure It is possible to connect level switch from the collecting tank for high and low level to the VTS-controller. It is possible to connect a external alarm to the VTS-controller. The VTS-controller is factory-programmed with standard setting (see setting) Part no. 230 VAC: 121 3151 32 Overall dimensions: 240 x 120 x 60 mm (Ix wx h) VTS-controlle - Content. assvseseciseete Drawing VTS-controller . 3 ‘Component overview Connection diagram Mouning . Controller overview How to use Setting ss... Historic information .... Supervisor menu. VTS - controller CB ovooeis sou HUH (ex=3) ene (ena) wav, Ioesoynuuons vye'zn oh not2 wae Component overview J err Ta "ADE EAD 82K soyequeg Sin (wont av noua Connection diagram we, |Elenrnn Ea ELE] BFE Ey HEE vee aa “yee ava vernon, vaeawoo koenwaes wrTIOUNED SIA Jas Lid i fat i e 5 g Mounting - VTS-controller PS! In order to avoid electric shock, pull out the electric contact. Do not reconnect it until the VTS- controller is assembled! Lift off the lid to accsess the holes in the bottom of the panel. Screw the panel securely to the wall, replace the lid and tighten the screws. Use a screwdriver to remove the two small strips on the top of the panel to get accsess to the four lock screws. Remove these. Electronic control When a vacuum transmitter is connected to the VTS-controller, the transmitter will be automatic detected when the controller is switched on. The function and menu will then be for CVS 1. If no transmitter is connected to the controller the function and menu will be for CVS 2: ‘Vacuum Teilet System, Controller type: CVS Hot By The automatic start and stop of the Vacuumarator is controlled by the VTS-controller. If the default setting can be used, the system is ready for immediate use. Default setting Is based on: a. The Vacuumaratnr i set to start at 40% vacuum, and stop at 60% vacinim b, Max runtime for the Vacuumarator is 40min. Use and operation: | Press a to switch on the controller. All indicator lights will light up for 3 sec. In the display the information u's will appear, follow up by (vs!, and then the software version (ex. v1.1) ‘Simultaneously the alarm will run for 2 sec. The system is now ready for use. The Vacuumarator will start in auto ‘mode, and the display will show the current vacuum level press UM to switch off the controte. This must always be done before installation, maintenance or repair. To run the Vacuumarator manually. press eI for 5 sec. ‘The Vacuumarator vill then run continuously To stop the Vacuumarator, press =! once more To the left in the display a sign will indicate in which mode the controller is. Indicator high eve Indiator ou fvel Incieator Vacuumarstor Indeator Vacuum love Of bution Indeator Power on On button aril eparaion Vasurar Display ). Display selector Electronic control Settings menu: Press & and es simultaneously to activate or deactivate the menu, New set- tings can be saved by going to the next menu, press G to exit the menu. ress ' Display fe Adjustment of vacuum level for stop ( Vacuumarator (10-95%) eee Values con be changed by pressing “RUN Press G ’ Display: up: Adjustment of vacuum level for start 7 Vacuumarator (5-30% below stop level) P 40 |) DESH SSy ote ~~) Values can be changed by pressing “RUN Press Mode select (Off / Manual / Auto): to switch on the controller. The Vacuumarator will start running in Auto mode. Press HH | LED: ‘Auto moce (normal) ‘The Vacuumarator starts and stops based on set point. To the left in the display an indicator wil indicate Auto mode, ‘To the right n the display a status indicator will indicate "1" = ‘when the Vacuumarator runs. Press , Auto moce (normal) ‘The Vacuumarator starts and stops based on set point. ‘To the left inthe display an indicator wil indicate Auto mode ‘To the right in the display a status indicator will indicate “O” ress ' of ‘The Vacuumarator can be stopped by pressing "RUN" ance. To the left in the display an indicator wil indicate Off mode. ‘To the right in the display a status indicator will indicate “0 when the Vacuumarator stops Press Y Display: pases um: Manual a ‘The Vacuurrarator will run continuously Ye To the left nthe Glspay an Indicator will incicate Manual | To the right in the display a status Indicator wil indicate "3" Wwe mode. Press "RUN” once to switch off Manual mode. mes _ _ To display information on performance, press iS) Y LED: eh Electronc control - user menu History: ‘The value in the display will show the total run time for the Vacuumarator The example to the left shows that the Vacuumarator has pe x =) Operation failure (stop Display: Co es (Rr) GQ ress ' The value in the display shows the number of collection tank max, level warnings. NB! This value will only change i a level indicator is installed. The example to the left shows that there has been 25 war- rings in the system, Press a max runtime): Stop Vacuumarator The Vacuumarator has stopped. Press “SELECT” to show the information in the display ress Bi | Stop Vacuumarator (Max runtime) ‘The Vacuumarator has stopped because "max runtime” (ee setting) ‘The error may be leakage in the pipes/piping system Switch OFF and turn ON the controller for Reset ress ‘The history information will automatically switch off after one min. Electronic control - supervisor menu In supervisor menu it’s possible to activate special function. Press G and B simultaneously as the power is switched on to activate the menu. New settings will automatically be saved by selecting next menu, or exit supervisor menu. ‘Switch OFF the controller to exit the supervisor menu. press | Display: Leo: ‘Adjustment of max runtime, Vacuumarator (5 - 60 min.) Default setting: 40 min values can be changed by pressing *RUN". vated), | L Change function for the manual run switch Press the "RUN/DISCHARGE" to alter between impulse or ‘on/off function with discharge mode, (To use discharge mode, the low level switch must be acti- Press Y Activate discharge mode (low level switch): raze "RUN/DISCHARGE” to ewitch on/off the level awiten Press Startup procedure and checklist 1 Fill the transparent suction chamber with water 2 Connect power and turn on the VTS controller (press ON button) 3 Adjust vacuum level. The factory setting is 60% vacuum. For condensate water systems, adjust to 50% vacuum - see page 28 4 Verify that the system has na leaks, and retains a stable vacuum level The pump should start no more than once per hour when the system is notin use. 5 Adjust opening times of all ED valves. The valves should close 2 seconds after the interceptor tanks have been emptied. Fill water up to the edge of the glass when filling the pump for the first time Rotate edjustment knob toset the opening time h Checked by Procedure step: (date and signature): Comments TFill with water 2 Connect and turn on. 3 Agjust vacuum level ‘Verify no leaks ‘5 Adjust opening times

You might also like