ANF020 Hoist/Pulldown Drive Field Loss This fault occurs if the hoist / pulldown 1. Check the operation and/or wiring of the control field current is less than 50% of hoist/pulldown motor and control weak field current. This will prevent the hoist/pulldown drive from operating. ANF021 Hoist/Pulldown Drive Field Over This fault occurs if the hoist / pulldown 1. Check the operation and/or wiring of the Current motor field current exceeds 15 A (120% of hoist/pulldown motor. maximum running current of 12.5 A). This will prevent the hoist/pulldown drive from operating. ANF022 Hoist/Pulldown Drive Blower This fault occurs when there is no feedback 1. Check the operation and/or wiring of the Control Fault from the hoist / pulldown motor blower. blower motor and motor contactor. This will prevent the hoist/pulldown drive 2. On the operator display, check for feedback from operating. from the blower motor. ANF023 Hoist/Pulldown Drive Input This fault occurs if the power supply to the 1. Check the connection and/or wiring of the Power Fault Hoist / Pulldown control circuitry is hoist/pulldown control panel. disconnected. This will prevent the hoist/pulldown drive from operating. ANF024 Hoist/Pulldown Stall Fault This fault occurs when hoist / pulldown 1. Adjust the speed of the hoist/pulldown motor stall detection settings are 95% of motor. stall armature current and hot armature voltage drop at 100% stall armature current. This will prevent the hoist/pulldown drive from operating. ANF025 Hoist/Pulldown This fault occurs if the drive armature 1. Check the operation and/or wiring of the Drive Incomplete Sequence current signal is not active before a certain hoist/pulldown drive. delay. This will prevent the hoist/pulldown 2. Check the incoming voltage to the drive from operating. hoist/pulldown control panel. ANF026 House Fan Fault This fault occurs when either the pressure 1. Check the operation of the pressure fan fan motor contactor or the pressure fan motor and pressure fan bleed motor. bleed motor contactor has not pulled in 2. Check the operation and/or wiring of the after 10 seconds delay. motor contactors. ANF027 Water Injection Drive Fault This fault occurs if the air pressure for 1. Check the operation and/or wiring of the water injection drops below 10 PSI. water injection drive. 2. Check the water level in the tank.