Critical

Fault Message Description / Effect Recommended Action Fault


ANF020 Hoist/Pulldown Drive Field Loss This fault occurs if the hoist / pulldown 1. Check the operation and/or wiring of the
control field current is less than 50% of hoist/pulldown motor and control
weak field current. This will prevent the
hoist/pulldown drive from operating.
ANF021 Hoist/Pulldown Drive Field Over This fault occurs if the hoist / pulldown 1. Check the operation and/or wiring of the
Current motor field current exceeds 15 A (120% of hoist/pulldown motor.
maximum running current of 12.5 A). This
will prevent the hoist/pulldown drive from
operating.
ANF022 Hoist/Pulldown Drive Blower This fault occurs when there is no feedback 1. Check the operation and/or wiring of the
Control Fault from the hoist / pulldown motor blower. blower motor and motor contactor.
This will prevent the hoist/pulldown drive 2. On the operator display, check for feedback
from operating. from the blower motor.
ANF023 Hoist/Pulldown Drive Input This fault occurs if the power supply to the 1. Check the connection and/or wiring of the
Power Fault Hoist / Pulldown control circuitry is hoist/pulldown control panel.
disconnected. This will prevent the
hoist/pulldown drive from operating.
ANF024 Hoist/Pulldown Stall Fault This fault occurs when hoist / pulldown 1. Adjust the speed of the hoist/pulldown
motor stall detection settings are 95% of motor.
stall armature current and hot armature
voltage drop at 100% stall armature
current. This will prevent the hoist/pulldown
drive from operating.
ANF025 Hoist/Pulldown This fault occurs if the drive armature 1. Check the operation and/or wiring of the
Drive Incomplete Sequence current signal is not active before a certain hoist/pulldown drive.
delay. This will prevent the hoist/pulldown 2. Check the incoming voltage to the
drive from operating. hoist/pulldown control panel.
ANF026 House Fan Fault This fault occurs when either the pressure 1. Check the operation of the pressure fan
fan motor contactor or the pressure fan motor and pressure fan bleed motor.
bleed motor contactor has not pulled in 2. Check the operation and/or wiring of the
after 10 seconds delay. motor contactors.
ANF027 Water Injection Drive Fault This fault occurs if the air pressure for 1. Check the operation and/or wiring of the
water injection drops below 10 PSI. water injection drive.
2. Check the water level in the tank.

Page 82 of 128 Issued :