Autocom Trucks CDP+ | Release 2020 (2020.

23) | VCI: 100251 1

STO u Andriiv
Address: Ternopil, navproty avtorynku
Postal address: 46005
Phone: 067 533 1530
Fax:
E-mail: xxx@gmail.com

Mechanic:
Date: 31.01.2022
Car licence no: ȺɆ
VIN:
Mileage:
Vehicle: Volvo Bus Chassis - B11R [11-13] - 2011

Fault codes
Engine electronics
DTC Description

MID128-PID84 - Road speed


- Abnormal updating rate
- Inactive

First error occurrence 14/09/2021 08:09 Date /


time
FMI FMI-9
Frequency counter 94
Last error occurrence 29/01/2022 07:40 Date /
time
MID128-PID85 - Cruise control status
- Abnormal updating rate
- Inactive

First error occurrence 16/12/2021 18:35 Date /


time
FMI FMI-9
Frequency counter 11
Last error occurrence 29/01/2022 07:40 Date /
time
MID128-PID91 - Accelerator pedal position
- Abnormal updating rate
- Inactive

First error occurrence 16/12/2021 18:35 Date /


time
FMI FMI-9
Frequency counter 11
Last error occurrence 29/01/2022 07:40 Date /
time
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 2
MID128-PID98 - Engine oil level
- Signal too low
- Inactive

First error occurrence 27/01/2022 11:36 Date /


time
FMI FMI-1
Frequency counter 1
Last error occurrence 27/01/2022 11:36 Date /
time
MID128-PID190 - Engine speed
- Inactive

First error occurrence 05/11/2021 10:55 Date /


time
FMI FMI-0
Frequency counter 1
Last error occurrence 05/11/2021 10:55 Date /
time
MID128-PSID42 - Interrupted dosage activity
- Unknown fault symptom
- Inactive

First error occurrence 00:00:00 Date / time


FMI FMI-14
Frequency counter 149
Last error occurrence 00:00:00 Date / time
MID128-PSID46 - NOx indication fault
- Intermittent or defective data.
- Inactive

First error occurrence 00:00:00 Date / time


FMI FMI-2
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID128-PSID98 - Boost air system
- Signal too low
- Inactive

First error occurrence 16/05/2021 07:52 Date /


time
FMI FMI-1
Frequency counter 255
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 3
Last error occurrence 13/01/2022 13:44 Date /
time
MID128-PSID115 - Empty reactant tank
- Signal too low
- Inactive

First error occurrence 00:00:00 Date / time


FMI FMI-1
Frequency counter 13
Last error occurrence 00:00:00 Date / time
MID128-PPID386 - Exhaust temperature sensor before SCR cat
- Intermittent or defective data.
- Inactive

First error occurrence 00:00:00 Date / time


FMI FMI-2
Frequency counter 110
Last error occurrence 00:00:00 Date / time
MID128-PSID229 - J1939 Communication interference, data link, UDS
- Abnormal updating rate
- Inactive

First error occurrence 00:00:00 Date / time


FMI FMI-9
Frequency counter 6
Last error occurrence 00:00:00 Date / time

Brake (EBS Gen3 (Brakes) - MID136 - 4X2)


DTC Description

MID136-SID2 - Wheel speed sensor ABS axle 1 right


- Mechanical error
- Inactive
- FMI-7

First error occurrence 09/06/2021 21:33 Date /


time
FMI FMI-7
Frequency counter 20
Last error occurrence 21/10/2021 16:54 Date /
time
MID136-SID70 - Pad wear sensor, axle 1 left
- Signal too low
- Inactive
- FMI-1
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 4
First error occurrence 24/01/2022 11:23 Date /
time
FMI FMI-1
Frequency counter 1
Last error occurrence 24/01/2022 11:23 Date /
time
MID136-PSID201 - SAE J1939 Data link interruption, vehicle control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 09/10/2021 08:23 Date /


time
FMI FMI-9
Frequency counter 1
Last error occurrence 09/10/2021 08:23 Date /
time
MID136-PSID200 - SAE J1939 Data link interruption, engine control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 09/10/2021 08:23 Date /


time
FMI FMI-9
Frequency counter 2
Last error occurrence 09/10/2021 08:23 Date /
time

Brake (EBS Gen3 (Brakes) - MID136 - 6X2)


DTC Description

MID136-SID2 - Wheel speed sensor ABS axle 1 right


- Mechanical error
- Inactive
- FMI-7

First error occurrence 09/06/2021 21:33 Date /


time
FMI FMI-7
Frequency counter 20
Last error occurrence 21/10/2021 16:54 Date /
time
MID136-SID70 - Pad wear sensor, axle 1 left
- Signal too low
- Inactive
- FMI-1

First error occurrence 24/01/2022 11:23 Date /


time
FMI FMI-1
Frequency counter 1
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 5
Last error occurrence 24/01/2022 11:23 Date /
time
MID136-PSID201 - SAE J1939 Data link interruption, vehicle control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 09/10/2021 08:23 Date /


time
FMI FMI-9
Frequency counter 1
Last error occurrence 09/10/2021 08:23 Date /
time
MID136-PSID200 - SAE J1939 Data link interruption, engine control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 09/10/2021 08:23 Date /


time
FMI FMI-9
Frequency counter 2
Last error occurrence 09/10/2021 08:23 Date /
time

Instrument (Instrument - MID140 (Instrument) - (Vehicles from build-week 37,


2005 ))
DTC Description

MID140-PID158 - Battery potential; voltage switched


- Short circuit to ground or +30
- Inactive

First error occurrence 21/12/2021 09:05 Date /


time
FMI
Frequency counter 2
Last error occurrence 22/12/2021 07:50 Date /
time
MID140-PSID200 - Communication interference, data link, engine control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 00:00:00 Date / time


FMI FMI-9
Frequency counter 2
Last error occurrence 00:00:00 Date / time
MID140-PSID238 - Communication interference, data link, control unit climate unit
- Component failures
- Inactive
- FMI-12
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 6
First error occurrence 00:00:00 Date / time
FMI FMI-12
Frequency counter 1
Last error occurrence 00:00:00 Date / time

Multifunction (Lighting control module - MID216)


DTC Description

MID216-PSID5 - Front fog lights


- Open circuit
- Inactive
- FMI-5

First error occurrence 11/01/2022 18:01 Date /


time
FMI FMI-5
Frequency counter 2
Last error occurrence 26/01/2022 19:22 Date /
time
MID216-PSID23 - Tail light left, side marking light left rear
- Open circuit
- Inactive
- FMI-5

First error occurrence 14/01/2022 12:53 Date /


time
FMI FMI-5
Frequency counter 7
Last error occurrence 00:00:00 Date / time
MID216-PSID11 - Right brake light
- Open circuit
- Inactive
- FMI-5

First error occurrence 27/01/2022 13:07 Date /


time
FMI FMI-5
Frequency counter 1
Last error occurrence 27/01/2022 13:07 Date /
time
MID216-PSID34 - Power supply 1
- Short circuit to ground or +30
- Inactive

First error occurrence 00:00:00 Date / time


FMI
Frequency counter 2
Last error occurrence 27/01/2022 19:03 Date /
time
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 7
MID216-PSID35 - Power supply 2
- Short circuit to ground or +30
- Inactive

First error occurrence 00:00:00 Date / time


FMI
Frequency counter 2
Last error occurrence 27/01/2022 19:03 Date /
time
MID216-PSID36 - Power supply 3
- Short circuit to ground or +30
- Inactive

First error occurrence 00:00:00 Date / time


FMI
Frequency counter 2
Last error occurrence 27/01/2022 19:03 Date /
time
MID216-PSID37 - Power supply 4
- Short circuit to ground or +30
- Inactive

First error occurrence 00:00:00 Date / time


FMI
Frequency counter 2
Last error occurrence 27/01/2022 19:03 Date /
time
MID216-PSID38 - Power supply 5
- Short circuit to ground or +30
- Inactive

First error occurrence 00:00:00 Date / time


FMI
Frequency counter 2
Last error occurrence 27/01/2022 19:03 Date /
time
MID216-PSID39 - Power supply 6
- Short circuit to ground or +30
- Inactive

First error occurrence 00:00:00 Date / time


FMI
Frequency counter 2
Last error occurrence 27/01/2022 19:03 Date /
time
MID216-PSID4 - Dipped beam right side
- Open circuit
- Active
- FMI-5

First error occurrence 28/01/2022 13:11 Date /


time
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 8
FMI FMI-5
Frequency counter 2
Last error occurrence 30/01/2022 21:59 Date /
time

Multifunction (Tachograph - MID220)


DTC Description

MID220-SID251 - Power supply


- Component failures
- Inactive
- FMI-12

First error occurrence 00:00:00 Date / time


FMI FMI-12
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID220-PSID12 - Sensor power supply
- Open circuit
- Inactive
- FMI-5

First error occurrence 00:00:00 Date / time


FMI FMI-5
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID220-PSID6 - Pulse generator COM
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 00:00:00 Date / time


FMI FMI-9
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID220-PSID31 - Tachograph
- Unknown fault symptom
- Inactive
- FMI-11

First error occurrence 00:00:00 Date / time


FMI FMI-11
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID220-PSID13 - Driving without card (driver card or workshop card)
- Unknown fault symptom
- Inactive
- FMI-14
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 9
First error occurrence 00:00:00 Date / time
FMI FMI-14
Frequency counter 1
Last error occurrence 00:00:00 Date / time

Multifunction (Vehicle ECU - MID144)


DTC Description

MID144-PID46 - Vehicle wet tank pressure


- Signal too low
- Active
- FMI-1

First error occurrence 31/01/2022 12:08 Date /


time
FMI FMI-1
Frequency counter 1
Last error occurrence 31/01/2022 12:08 Date /
time
MID144-SID231 - SAE J1939 Data link
- Intermittent or defective data.
- Inactive
- FMI-2

First error occurrence 27/01/2022 19:06 Date /


time
FMI FMI-2
Frequency counter 1
Last error occurrence 27/01/2022 19:06 Date /
time
MID144-PID84 - Road speed
- Intermittent or defective data.
- Inactive
- FMI-2

First error occurrence 24/10/2021 17:57 Date /


time
FMI FMI-2
Frequency counter 44
Last error occurrence 24/01/2022 15:33 Date /
time
MID144-PPID430 - Air drier, regeneration
- Signal too high
- Inactive
- FMI-0

First error occurrence 22/10/2021 08:56 Date /


time
FMI FMI-0
Frequency counter 56
Last error occurrence 31/01/2022 11:54 Date /
time
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 10
MID144-PPID312 - Air drier, regeneration
- Signal too high
- Inactive
- FMI-0

First error occurrence 30/01/2022 10:39 Date /


time
FMI FMI-0
Frequency counter 14
Last error occurrence 31/01/2022 11:54 Date /
time
MID144-PSID25 - Air leakage
- Signal too low
- Inactive
- FMI-1

First error occurrence 27/10/2021 15:19 Date /


time
FMI FMI-1
Frequency counter 255
Last error occurrence 30/01/2022 20:39 Date /
time
MID144-PSID230 - Software fault!
- Open circuit
- Inactive
- FMI-5

First error occurrence 27/01/2022 19:06 Date /


time
FMI FMI-5
Frequency counter 5
Last error occurrence 28/01/2022 12:30 Date /
time

Suspension (ECS Gen3 (Air Suspension) - MID150 - 4X2)


DTC Description

MID150-SID3 - Solenoid valve axle 2 right


- Short circuit to ground
- Inactive
- FMI-6

First error occurrence 13/05/2021 19:12 Date /


time
FMI FMI-6
Frequency counter 2
Last error occurrence 13/05/2021 19:14 Date /
time
MID150-SID24 - Pressure sensor axle 2 right
- Short circuit to ground or +30
- Inactive

First error occurrence 09/06/2021 19:41 Date /


time
Autocom Trucks CDP+ | Release 2020 (2020.23) | VCI: 100251 11
FMI
Frequency counter 1
Last error occurrence 09/06/2021 19:41 Date /
time
MID150-PSID201 - Communication interference, data link, vehicle control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 00:00:00 Date / time


FMI FMI-9
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID150-PSID200 - Communication interference, data link, engine control unit
- Abnormal updating rate
- Inactive
- FMI-9

First error occurrence 00:00:00 Date / time


FMI FMI-9
Frequency counter 1
Last error occurrence 00:00:00 Date / time
MID150-PSID22 - Air suspension Channel drive axle
- Mechanical error
- Inactive
- FMI-7

First error occurrence 00:00:00 Date / time


FMI FMI-7
Frequency counter 1
Last error occurrence 00:00:00 Date / time