Professional Documents
Culture Documents
NEW Photometry
pH
The portable photometer pHotoFlex demonstrates its capability with 0.63 in and 1.1 in (16 mm
complex tasks in environmental and process monitoring at changing and 28 mm) cuvettes
locations.
ORP
100 user-defined methods
pHotoFlex features a highly robust optical system, thus being optimally suited for
mobile applications under changing conditions. The LEDs plus filters for 6 wave-
Integrated pH measurement
lengths have a remarkably low power consumption and deliver accurate measuring
results. Most standard parameters can be easily determinated, and a correct coloration
measurement can be obtained at a wavelength of 436 nm. Moreover, a comfortable
ISE
dilution function is available for assistance in special cases.
The low power consumption allows more than 3000 measurements with only 4 AA
batteries. Additionally, pHotoFlex can be changed over to rechargeable battery
operation or upgraded with the LabStation (see accessories p. 91).
Oxygen
(D.O.)
Whichever alternative for rechargeable battery use you may choose, you can return
to normal battery operation any time in the field. One single set of spare batteries
is sufficient.
Conductivity
The smart adapter solution
parameter
Due to an ingenious flap mechanism, the adapter is integrated in the instrument
Multi-
and cannot get lost. Just slide upward the magnetic lid and insert the 28 mm roud
cuvette. Alternatively, flip up the adapter with a movement of the hand and measure
with a 16 mm, round cuvette. pHotoFlex can measure cuvettes from 91 ... 104 mm
in height and allows the use of different test sets. The intuitional menu user guid-
Respiration
BOD/
ance allows trouble-free in-field measuring without having to study a handbook.
All methods for test sets can be updated and extended via the internet. For user-
defined measuring routines, 100 program storage places are available. Software
updates, too, can be made via the internet.
Photometers
The instrument with opened adapter and chemicals
pH function
Turbidity
The integrated pH function allows measurings of pH 0 ... 16 with automatic buffer
recognition (TEC/NIST). Temperature compensation is automatic within the
permitted range of 23 … 212 °F (– 5 ... 100 °C). WTW‘s MultiCal®-routine allows
the automatic calibration with up to 3 calibration points. WTW offers a large
selection of pH sensors as an optional accessory: For field use, the maintenance-free
Counter
Colony
with pH sensor
For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 89
Parameter
pHotoFlex Turb and Accessories
Accessories
Making your work easier
pH
The rechargeable battery set pHotoFlex RB Included in delivery is the rechargeable battery pack
pHotoFlex RB and a software package. This simplifies laboratory
The set consists of a rechargeable battery pack with universal
work. Due to the constant environmental conditions and a
ORP
power supply. For the connection to a PC via RS 232, the
permanent power supply, the program data of routine
AK540/B cable (Ordering No. 902 842) is required.
measurings can be read via bar-code and carried out without
zero-adjusting. The input mask via PC simplifies the input of
user-defined methods too.
For the connection of the LabStation to a PC, the AK Labor
ISE
The LabStation
cable (Ordering No. 902 758) p. 113 is required.
pHotoFlex LS
Some bar-code readers can be connected via RS 232, too.
The LabStation
This simplifies routine work, as bar-codes are offered for the
pHotoFlex LS up-
test sets in the analysis directions and on WTW’s webpage
Oxygen
(D.O.)
grades the models
(www.WTW.com).
pHotoFlex and
pHotoFlex Turb as well as The LabStation serves as charging station for the battery pack.
the new turbidity meter
Conductivity
LabStation Turb 430 IR (p. 108) to a small
laboratory instrument.
Technical Data
parameter
Model pHotoFlex pHotoFlex Turb
Multi-
Light source LED LED
Wavelengths nm 436, 517, 557, 594, 610, 690 436, 517, 557, 594, 610, 690 + 860
User-defined methods 100 100
Respiration
Timer 3 3
BOD/
Data storage 1000 data sets 1000 data sets
pH 0-16 0-16
Turbidity 0-1100 NTU / FNU 0-1100 NTU/FNU
Photometers
Accuracy Photometry <2 nm < 2nm
pH ±0.01 pH ±0.01 pH
Turbidity (NTU/ FNU) — 0-9.99: 0.01; 10-99: 0.1; 100 -1000: 1
Auto-zero adjustment/calibration: Photometry With start of new method, with LabStation once a day With start of new method, with LabStation once a day
pH / Turbidity 3 point 3 point
Interface RS 232, USB via adapter (optional) RS 232, USB via adapter (optional)
Measuring parameters Photometry, pH Photometry, pH, Turbidity Turbidity
Battery Type AA batteries 4x1.5 V, for approx. 3000 measurements Type AA batteries 4x1.5 V, for approx. 3000 measurements
Reachargeable battery Optional: rechargeable battery or LabStation Optional: rechargeable battery or LabStation
Test marks cETLus cETLus
Counter
Ordering Information
pHotoFlex Order No.
Software/
For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 91