This section describes how to configure 10GE LAN services through TN52TQX boards and
cross-connect ODU2 or ODU2e signals to TN54NS3 boards in one station. The other station
is configured exactly the same.
Prerequisites
You are an NMS user with "Operator Group" privilege or higher.
Legend Information
Figure 2-23 shows legend information about U2000 operations.

Application Diagram

Cross-Connection Diagram
NOTE
In this configuring process, a TN54NS3 board in compatible mode is used as an example in Figure

Procedure
Step 1 Configure attributes of client-side ports on the TN52TQX board of station A.
1. In the NE Explorer, select the TN52TQX board that you want to configure, and then
choose Configuration > WDM Interface from the Function Tree.
2. Click By Board/Port (Channel), and select Channel from the drop-down list.
3. Select the Basic Attributes tab.
4. Select the ClientLP port, the service type that needs to be set, and then double-click the
corresponding parameter domain to set the following parameters.
– Service Type: 10GE LAN
– Port Mapping: Bit Transparent Mapping (11.1G)

NOTE

5
:When the service type is 10GE LAN, the service mapping path can be Bit Transparent
Mapping (11.1G) or MAC Transparent Mapping (10.7 G) . Users can select the service
mapping path based on the service transmission requirements.
When Port Mapping is set to Bit Transparent Mapping (11.1G), the service cross-connect
granularity is ODU2e. When Port Mapping is set to MAC Transparent Mapping (10.7 G) , the
service cross-connect granularity is ODU2.

5. Click Apply. In the dialog box that is displayed, click OK.


6. Click Query, In the dialog box that is displayed, click Close. Ensure that the query result
is consistent with the configuration.
Step 2 Configure attributes of client-side ports on the TN54NS3 board of station A.
1. In the NE Explorer, select the TN54NS3 board and choose Configuration > WDM
Interface from the Function Tree.
2. Click By Board/Port (Channel) and choose Channel from the drop-down list.
3. Select the Basic Attributes tab.
4. Select the ODU2 port. Double-click the Service Mode parameter and then select ODU2
or Automatic.
5. Select the ODU3 port. Double-click the Service Mode parameter and then select
Automatic or MIX.

6. On the Advanced Attributes tab, select the ODU2 port and ODU3 port and double-click
the Line Rate parameter and set to Speedup Mode.

– When Port Mapping of the ClientLP port on the TQX board is set to Bit
Transparent Mapping (11.1 G), Line Rate of the corresponding ODU2 port of the
TN54NS3 board must be set to Speedup Mode. Line Rate of the ODU3 port must
be set to Speedup Mode.
– When Port Mapping of the ClientLP port on the TQX board is set to MAC
Transparent Mapping (10.7 G) , Line Rate of the corresponding ODU2 port of the
TN54NS3 board must be set to Standard Mode. Line Rate of the ODU3 port can be
set to Standard Mode or Speedup Mode.
Port Mapping and Line Rate of the boards that services pass must be consistent;
otherwise, service interruption occurs.

7. Click Apply. In the dialog box that is displayed, click OK.


8. Click Query. Ensure that the query result is consistent with the configuration.
Step 3 In the NE Explorer,configure ODU2 services from the ClientLP port of the TN52TQX board