Professional Documents
Culture Documents
N2XRY
N2XRY
Construction Data
Application : Copper Conductor
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical XLPE Insulation
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
Electrical Data
Conductor Inductance Current - Carrying Capacity at 30° C * Short
circuit current
Nom. DC AC Trefoil Flat
at
Cross Resistance Resistance formation formation in air in ground in air in ground 1 sec
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XRY
N2XRY 22xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / SWA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical XLPE Insulation
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Wire Armor
1.5 13.6 325 Special Features on Request Non-hygroscopic Tape
2.5 14.5 379 • Fire Resistance
• Oil Resistance PVC Sheath
4 15.7 448 • UV Resistance
6 16.8 530 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 19.4 783
• Anti Termite
16 22.0 982 • Anti Rodent
25 25.5 1,447 • Low Smoke Zero Halogen
35 28.0 1,765
50 30.5 2,106
Note :
70 35.0 2,765
Conductor Shape
95 39.5 3,746 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
120 43.5 4,465 conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
150 47.5 5,303 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
185 54.0 6,890
Standard Packing
240 59.5 8,463
1.5 - 95 sqmm supplied in wooden drum @ 1000 m
300 65.0 10,151 120 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XRY
N2XRY 33xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / SWA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical XLPE Insulation
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Wire Armor
1.5 14.1 351 Special Features on Request Non-hygroscopic Tape
2.5 15.1 415 • Fire Resistance
• Oil Resistance PVC Sheath
4 16.3 503 • UV Resistance
6 17.5 603 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 20.5 903
• Anti Termite
16 23.0 1,161 • Anti Rodent
25 27.0 1,709 • Low Smoke Zero Halogen
35 29.5 2,127
50 31.5 2,424
Note :
70 36.5 3,438
Conductor Shape
95 40.0 4,343 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
120 43.5 5,172 conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
150 49.5 6,675 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
185 54.0 7,977 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
240 60.0 9,995
Standard Packing
300 65.0 11,990 1.5 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XRY
N2XRY 44xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / SWA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable Copper Conductor
Cross Diameter Weight trunking and outdoors if increased mechanical
Section XLPE Insulation
protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Wire Armor
1.5 14.9 395 Special Features on Request Non-hygroscopic Tape
2.5 16.0 470 • Fire Resistance
• Oil Resistance PVC Sheath
4 17.4 575 • UV Resistance
6 19.5 798 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 22.0 1,058
• Anti Termite
16 25.5 1,518 • Anti Rodent
25 29.0 2,055 • Low Smoke Zero Halogen
35 32.0 2,585
50 35.5 3,040
Note :
70 41.0 4,305
Conductor Shape
95 45.0 5,476 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
120 51.5 7,064 conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
150 57.5 8,536 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
185 61.5 10,189 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
240 68.0 12,772
Standard Packing
300 73.5 15,380 1.5 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XRY 5 x (1.5-50) mm 2
0.6/1
N2XRY 5 x (1.5-50) mm 0.6/1
2
kV kV
Cu / XLPE / SWA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-1
Construction Data
Application : PVC Filler
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical Copper Conductor
Section protection is required or where high-pulling XLPE Insulation
Area approx. approx. stresses may occur during installation or PVC Inner Sheath
mm² mm kg/km operation.
Galvanized Steel Wire Armor
1.5 15.8 441 Special Features on Request Non-hygroscopic Tape
2.5 17.0 535 • Fire Resistance
• Oil Resistance PVC Sheath
4 19.3 768 • UV Resistance
6 21.0 921 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
10 23.5 1,235
• Anti Termite
16 27.0 1,765 • Anti Rodent
25 31.5 2,423 • Low Smoke Zero Halogen
35 34.5 3,057
50 40.0 4,099
Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 50 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
1.5 - 35 sqmm supplied in wooden drum @ 1000 m
50 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification