As per datasheet submitted for approval of Filters, it was earlier 1500 mm.

After
approval of documents we found that there is inconsistency in the height of filters. So
we have we revised the height to 1800 mm.
But to speed up the fabrication activity, we have given filters for fabrication after first
approval received on the mail. Since vessels have been designed as per ASME standard
section VIII Div. II, additional welding joint for height increase of 300 mm along the
periphery will not create or affect the strength or stability of shell as there is dead load
of media on lower part of shell.
Since, we have checked with hydrotest also, which is conducted on 7 kg/cm2 pressure
(which is more than the 1.5 times of working pressure i.e. around 4.5 kg/cm2.