Professional Documents
Culture Documents
Full-Spectrum Sensor
LR-W Series
FULL-
SPECTRUM
SENSOR
Stable Detection of
Changes in Appearance
LR-W Series
PRESENCE AND ABSENCE
WHAT IS
A FULL-SPECTRUM
SENSOR?
A Full-Spectrum sensor features unmatched detecting
capabilities that allow it to complete the simplest to the
most complex applications with ease. The LR-W Series is
one such sensor that can truly handle the Full-Spectrum of
applications.
PRODUCT DIFFERENTIATION
2
REGISTRATION MARKS
White LED
COLOUR VERIFICATION
3
4
UNMATCHED
DETECTION CAPABILITIES
EASE-OF-USE
User-Friendly Display
DURABILITY
Water Resistant
Dustproof
5
UNMATCHED DETECTING CAPABILITIES
Full-Spectrum Detection
Spectrum of Light
Targets with
Slight Colour Changes Metal Targets Tilted Targets
6
Superior Detecting Distance with Adjustable Spot
Minimum
spot
3.5 mm 9 mm 18 mm
With an impressive 500 mm range, the LR-W is able to solve applications that were once considered out of reach.
The LR-W also features an easy to adjust spot that can be widened or focused to provide the best detection based on the target.
These two features combine to make the LR-W a truly all-purpose solution.
Colour
Brightness
Surface Finish
By using the Auto Tuning function, the LR-W accounts for a target's colour, brightness, and surface finish to determine which
detection method is best suited for the given application. This helps to ensure stable detection regardless of target variations.
7
EASE-OF-USE
Simplified Calibration
One simple press is all that is needed to Detect difficult registration marks with a Innovative tuning option to set clear
stably match a specific product. simple Two-Point (2-P) Calibration. thresholds for target variation.
Master Calibration/
Master Addition Calibration
Colour inconsistencies, vibration, worn surfaces, and tilting or
angling of targets can all lead to unstable detection. Master
Calibration allows user's to teach the sensor these variations in
advance. Master Addition Calibration enables conditions to be
Products fluttering on conveyor belts Colour variances within products easily added as they arise.
8
Intuitive Display and Indicators
The LR-W features a highly visible 7-segment display that The highly visible indicator is bright and can clearly be seen
provides constant feedback, as well as indicators to show from long distances.
detection mode and stability.
Seamless Integration
Same model
The LR-W has selectable NPN or PNP outputs in the same The LR-W Series offers a standard M12 4-pin quick disconnect
unit, making it easy to standardise on different machine types. option for easy wiring.
25.4 mm
The LR-W features a standard mounting pitch of 25.4 mm, If flexible mounting is required, an adjustable mounting
allowing it to easily mount on existing brackets. bracket is also available.
9
DURABILITY
The LR-W Series meets the requirements of IP65 and IP67 These IP Ratings also allow the LR-W to perform in dusty or
for areas requiring washdown. dirty environments.
Robust Housing
The die cast metal housing can withstand impact from The rigid metal housing of the LR-W allows for secure
products, tools, or workers. mounting without the fear of damage to the unit.
10
Additional Lineup
Difficult Assemblies
Versatile Options
Networking
Unaffected by Appearance
11
LR-W70(C) LR-W Series Small/Dual Spot Model
When precise
detection is
necessary:
The small spot and dual spot
options allow for versatile and
Detection Range
stable detection.
30 to 70 mm
1.6 × 2.9 mm
Confirmation of proper chip orientation Weld seam detection on metal coil stock
12
Dual Spot Detection
The innovative usage of dual spot technology provides a level of precise appearance
detection that has never been seen before. The LR-W70(C) also offers two unique
sensing styles when using Dual Spot Detection.
No
OFF ON Tuning OFF ON
Immediately detect registration marks without calibrating No calibration necessary even when switching targets
OK NG NG
Difficult Marks: Ignore design variables Ensure proper combination of two components by referencing two spots individually.
No Marks: Identify repeating patterns
13
LR-WF10(C) LR-W Series Fibre Extension Model
Compatible
Fibre Units
P.21-22
When unique
mounting is
required:
The versatile fibreoptic lineup ensures
detection in any situation.
Accessible Controls
Simple and accessible remote programming is possible when
using fibreoptic heads.
Versatile Options
High temperature, high flex, and numerous mounting options are
all available in the extensive fibreoptic lineup.
14
Mounting Constraints Require a Small Spot and Small Head
Through the use of built-in or attachable lenses, certain fibre heads are able to
achieve exceedingly small spots for detection.
APPLICABLE HEADS
Environmental Concerns
Side View (FU-31, FU-35TZ) Area Beam (CZ-12) Definite Reflective (FU-40S)
Innovative head designs allow for Monitoring an area provides stable Ignore any appearance changes that do
unobtrusive mounting in tight spaces. detection of non-repeatable targets. not occur within a designated window.
15
MU-N Series Multi-Sensor Controller
When additional
functionality is
needed:
Increased I/O, network compatibility,
The LR-W Series can be connected to the
and more, further expand the sensor's MU-N to allow for increased functionality.
capabilities.
Analogue 4 to 20 mA or 0 to 10 V
The MU-N Series controller offers customisable I/O. This The combination of an OLED and 7-Segment Display allows
includes both control outputs and a voltage/current analogue users to quickly view data in real time. The MU-N also has the
output. ability to display live graphs for easy machine monitoring.
By pairing the MU-N Series with the KEYENCE NU The Settings Back-Up Function allows users to save sensor
Series, users can transmit data over a standard settings on the MU-N and quickly transfer them to new
industrial network. Compatible networks include sensors that are attached.
EtherNet/IP™, EtherCAT, and PROFINET.
16
LR-Z & LR-T Series Position Based Sensor Series
When colour/
contrast needs
to be ignored:
Distance-based measuring principles
enable stable presence detection of any
object.
17
Lineup
Type Detecting distance Min. spot diameter Light source Model Weight
Cable Approx.
LR-W500
(2 m) 170 g
Adjustable spot
●
Approx. ø3.5 mm
Standard (at detecting distance of 100 mm)
White LED
Type ●
Approx. ø9 mm
30 to 500 mm (at detecting distance of 250 mm)
●
Approx. ø18 mm
(at detecting distance of 500 mm)
M12 connector
Approx.
(Cable sold LR-W500C
110 g
separately)
Cable Approx.
LR-W70
(2 m) 130 g
M12 connector
Approx.
(Cable sold LR-W70C
75 g
separately)
Cable Approx.
LR-WF10
(2 m) 150 g
Detecting Distance and Min. Spot Diameter Based on Attached Fibre Head
Fibre Type White LED
(See Pages 21 & 22 for details)
M12 connector
Approx.
(Cable sold LR-WF10C
95 g
separately)
18
Mounting bracket Attachment
Type Applicable Sensors Model Material/weight Type Applicable Sensors Model Material/weight
SUS304,
Standard
LR-W500/ SUS304 Lustre PMMA,
mounting bracket
W70/ OP-88021*1 Approx. canceling LR-W500(C) LR-WA1*1 *2 etc.
(M3 screw × 2
WF10 110 g attachment Approx.
supplied)
5g
Small SUS304,
SUS304 PMMA,
mounting bracket LR-W70/ Lustre canceling
OP-88022*1 Approx. LR-W70(C) LR-WA2*1 *2 etc.
(M3 screw × 2 WF10 attachment
50 g Approx.
supplied) 7g
*1 When using LR-WA1 or LR-WA2, detecting range may decrease on targets with low reflectance.
Perform sufficient checks in the actual installation environment.
Zinc nickel
*2 When using the LR-WA1 or LR-WA2, the enclosure rating (IP65/IP67) is not met.
Adjustable bracket plating,
(M3 screw × 2 OP-88023 etc.
supplied) Approx.
110 g
LR-W500(C)/
W70(C)/
WF10(C)
Iron nickel
Adjustable bracket
plating
locking screw OP-88024
Approx.
(105 mm)
140 g
*1 The 4-pin M12 connector type may not be mounted in the orientation shown in the picture (connector
downward). Confirm the dimensions and surroundings carefully.
Cable
Appearance Cable material Sensor side Cable end Length Model Weight
2m OP-75721 Approx. 60 g
Cable:
5m OP-87272 Approx. 125 g
PVC (Polyvinyl chloride)
M12 4-pin
10 m OP-85502 Approx. 230 g
straight
2m OP-87636 Approx. 75 g
Cable:
PUR (Polyurethane)
10 m OP-87637 Approx. 330 g
Loose wires
2m OP-75722 Approx. 65 g
Cable:
5m OP-87273 Approx. 130 g
PVC (Polyvinyl chloride)
M12 4-pin
10 m OP-87274 Approx. 235 g
L-shape
2m OP-87640 Approx. 75 g
Cable:
PUR (Polyurethane)
10 m OP-87641 Approx. 330 g
19
Controller
Type Control output External input Analogue output Model Weight
*Six I/O wires available, see instruction manual for applicable wire allocations.
Power supply cable for MU-N Series Cable is not included with the controller. Must be purchased separately.
Appearance Applicable unit Cable material Cable end Controller side Length Model Weight
8-core loose wires MU-CB8 Approx. 150 g
Main unit
4-core loose wires MU-CB4 Approx. 120 g
2m
6-core loose wires MU-CB6 Approx. 130 g
Expansion unit
2-core loose wires MU-CB2 Approx. 100 g
PVC (Polyvinyl chloride) Connector
M12 4-pin
Main unit 0.3 m MU-CC4 Approx. 30 g
straight
2m OP-88025 Approx. 75 g
M12 4-pin
straight
10 m OP-88026*1 Approx. 280 g
PVC (Polyvinyl chloride) Connector
2m OP-88027 Approx. 75 g
M12 4-pin
L-shape
10 m OP-88028*1 Approx. 280 g
*1 The 10 m cable includes one spare connector for the controller side.
Connector set for sensor-to-controller connection This set is required when the sensor cable end is loose wires or when the sensor-to-controller cable is cut.
OP-87636 / 87637
For PUR (Polyurethane) cable OP-88030 Approx. 3 g
OP-87640 / 87641
20
Fibre unit specification when using LR-WF10(C) Unit: mm
Fibre unit length (Diameter) Minimum Model
Feature Type Appearance Detecting distance
Ambient temperature bend radius Weight
1 m Free-cut
(ø1.3 × 2)
18.5 FU-35TZ
M3 Hex-shaped Coaxial -40 to +50°C Approx.
7g
M3
500 ms: 47
100 ms: 32
Threaded and R2
10 ms: 12
Hex-shaped Fibres ToughFlex
1 ms: 7
1 m Free-cut
250 μs: 5
(ø1.3 × 2)
FU-35FZ
M3 Threaded Coaxial -40 to +50°C 17 Approx.
6g
M3
1 m Free-cut
ø1.0 × 2 500 ms: 33
R2 100 ms: 24
Cylinder 10 FU-49U
Diameter ø2 -40 to +50°C ToughFlex 10 ms: 9
(Set Screw Installation) Approx. 4 g
High-flex 1 ms: 4
ø2 250 μs: 3
2 m Free-cut
(ø1.3 × 2)
Beam spot diameter
M6
ø0.9 to 3.5 FU-10
-40 to +70°C 10 to 30
Focal distance Approx. 5 g
10 to 30
26.4 to 31.5
Small Spot
R25
Reflective
50 cm
cut not allowed.
Beam spot diameter
-40 to +70°C
Approx. ø0.1 Tip: ø3 FU-20
5 ± 1 *1
Focal distance Approx. 2 g
5
18
2 m Free-cut Thickness:
(ø2.2 × 2) 5.2 500 ms: 26 to 379
100 ms: 27 to 270
Focused Beam/ Aperture angle: R2 FU-40
-40 to +50°C 10 ms: 33 to 112
High-power Approx. 8° ToughFlex Approx. 23 g
1 ms: —
21 250 μs: —
2 m Free-cut
(ø2.2 × 2) 500 ms: 2 to 131
100 ms: 3 to 119
7.4 FU-40S
Definite-reflective Thin, Small -40 to +70°C R25 10 ms: 10 to 93
Approx. 25 g
1 ms: 12 to 79
19 250 μs: 13 to 68
17
2 m Free-cut
(ø1.0 × 2) ø2.8 500 ms: 30
ø2 100 ms: 20
FU-31
Sleeve Side view detection -40 to +70°C 15 R10 10 ms: 7
Approx. 5 g
15 1 ms: 3
250 μs: 2
Do not bend sleeve.
21
Lens + Fibre Unit Unit: mm
Beam spot Lens Fibre units
Type Focal distance
diameter Model Appearance Weight Minimum bend radius Appearance Model
-30 to +70°C R2
ToughFlex FU-35FZ
15.6 R2
ToughFlex FU-35TZ
Approx. 1 g
Small spot
-30 to +70°C R2
ToughFlex FU-35FZ
27 R2
ToughFlex FU-35TZ
Approx. 2 g
2 m Free-cut
-40 to +70°C
Small size Approx.
ø0.9 to ø3.5 10 to 30 CZ-10
adjustable spot 5g
1m
-40 to +70°C
Small size,
Approx.
side-view ø0.9 to ø1.5 3 to 15 CZ-11 IP40
13 g
adjustable spot
R25
1m
-40 to +70°C
Long detection
distance, Approx.
ø2 35 ±3 CZ-13
small 20 g
beam spot
2 m Free-cut
-40 to +70°C
Long detection
ø6 70 ±20 CZ-40
distance
Approx.
IP67
27 g
2 m Free-cut
-40 to +70°C
Small beam
ø1 16 ±4 CZ-41 R15
spot
2 m Free-cut
-40 to +70°C
Area beam spot, Approx.
— 5 to 20 CZ-12 R25 —
reflective 19 g
22
Sensor specifications
Type Standard Type Small/Dual Spot Type Fibre Type
2 m cable type LR-W500 LR-W70 LR-WF10
Model
M12 connector 4-pin type LR-W500C LR-W70C LR-WF10C
Detecting distance 30 to 500 mm 30 to 70 mm
Adjustable spot
Detecting Distance and Min. Spot Diameter Based on
Approx. ø3.5 mm at 100 mm
Min. spot diameter Approx. 1.6 × 2.9 mm at 50 mm Attached Fibre Head (See Pages 21 & 22 for details)
Approx. ø9 mm at 250 mm
Approx. ø18 mm at 500 mm
1-Spot Mode: 200 μs, 1 ms, 10 ms, 100 ms, 500 ms selectable
2-Spot Mode, Difference Monitoring: 500 μs, 2.5 ms, 20 ms,
Response time*1 200 μs/1 ms/10 ms/100 ms/500 ms selectable 200 ms, 999 ms selectable 250 μs, 1 ms, 10 ms, 100 ms, 500 ms Selectable* 2
2-Spot Mode, 2-Point Matching: 400 μs, 2 ms, 20 ms,
200 ms, 999 ms selectable
Light source White LED
Mutual interference reduction function Up to 2 units when alternate frequencies set
Timer OFF / ON delay/ OFF delay/ One-shot
Power voltage 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Power supply 65 mA or less (without load) at 24 VDC; 60 mA or less (without load) at 24 VDC; 50 mA or less (without load) at 24 VDC;
Current consumption*3
120 mA or less (without load) at 12 VDC 110 mA or less (without load) at 12 VDC 90 mA or less (without load) at 12 VDC
Control output NPN open collector/PNP open collector selectable, 30 VDC or less, 50 mA or less, remaining voltage: 2 V or less, N.O./N.C. selectable
I/O*4 Tuning /laser emission stop selectable, Short circuit current: 1 mA or less for NPN/ 2 mA or less for PNP
External input
For the applied voltage, see the wiring diagrams in the instruction manual. For the input times, see the time charts in the instruction manual.
Protection circuit Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection
Enclosure rating IP65 / IP67 (IEC60529) IP65 (IEC60529)*5*6
Ambient light Incandescent lamp: 10000 lux or less, Sunlight: 20000 lux or less
Environmental Ambient temperature -20 to +50°C (no freezing) -20 to +45°C (no freezing)
resistance Ambient humidity 35 to 85%RH (no condensation)
Shock resistance 1000 m/s2 in X, Y, Z axis directions respectively 6 times
Vibration resistance 10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z axis directions respectively, 2 hours
Case: Zinc die cast (Nickel chrome plating), Indicator cover: PPSU, Buttons: PES, Lens cover (except for Fibre type) and display: PMMA (scratch-resistant coating), Cable bushing: PBT
Material Cable (2 m cable type only): PVC, Spot adjustment dial(Standard type only): Iron (triiron tetraoxide coated), Connector ring (4-pin M12 connector type only): PMP,
Connector socket (4-pin M12 connector type only) : PEI, Fibre locking mount (Fibre type only): PBT, NBR, Silicone rubber, SUS304, SUSXM7 Adapter (Fibre type only): PBT
2 m cable type Approx. 170 g (including cable) Approx. 130 g (including cable) Approx. 150 g (including cable)
Weight
M12 connector 4-pin type Approx. 110 g Approx. 75 g Approx. 95 g
*1 When alternate frequencies are set, the response time increases by approximately 20%. *2 When using the IO-Link communication, if the response time is set in 1ms or more, it becomes approximately 10% slower.
*3 Standard type: 195 mA or less (at 10 V, with load), Small/Dual Spot type: 180 mA or less (at 10 V, with load), Fibre type: 160 mA or less (at 10 V, with load)
*4 IO-Link : Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over
the Internet, contact your nearest KEYENCE office.
*5 When the following small-diameter fibre units (the diameter of the cable is ø1.3 mm or ø1.0 mm) are used, the IP65 rating cannot be satisfied (FU-4F/66/91/93/43/63/63T etc.). When any small-diameter fibre units except for the above
are used, IP65 is applied.
*6 In any of the following cases, the IP65 enclosure rating cannot be satisfied.
●
When the waterproof adapter A/B are not used at the time of installation of a small-diameter fibre unit.
Spot diameter 50
LR-W500(C) Reference data of (mm) 45
distance vs. spot diameter (Typical) 40
35
Focused at 100 mm 30
25
Focused at 200 mm
20
Focused at 300 mm
15
Focused at 400 mm
10
Focused at 500 mm
5
Reference for minimum spot diameter 0 Distance
0 50 100 150 200 250 300 350 400 450 500 (mm)
Main circuit
Main circuit
Overcurrent
➃ Black ➁White
PLC, etc.
➂ Blue ➂Blue
0V 0V
Main circuit
PLC, etc.
Main circuit
➃Black
Overcurrent
2
➁White
Load
3 1
➂Blue ➂Blue
0V 0V 4
23
Controller specifications
MU-N11 MU-N12
Model
Main unit Expansion unit
Connected sensor LR-W500(C) LR-W70(C) LR-WF10(C) LR-W500(C) LR-W70(C) LR-WF10(C)
1-Spot Mode Single output: 1-Spot Mode Single output:
300 μs/1.1 ms/11 ms/ 300 μs/1.1 ms/11 ms/
100 ms/500 ms 100 ms/500 ms
selectable selectable
Single output: 2-Spot Mode Difference Monitoring: Single output: Single output: 2-Spot Mode Difference Monitoring: Single output:
300 μs/1.1 ms/11 ms/ 600 μs/2.6 ms/21 ms/ 350 μs/1.2 ms/13 ms/ 300 μs / 1.1 ms/ 11 ms / 600 μs/2.6 ms/21 ms/ 350 μs/ 1.2 ms/ 13 ms /
100 ms/500 ms 200 ms/1 s selectable 120 ms/600 ms 100 ms/ 500 ms 200 ms/1 s selectable 120 ms/ 600 ms
selectable 2-Spot Mode 2-Point Matching: selectable selectable 2-Spot Mode 2-Point Matching: selectable
Response time
Multiple output: 500 μs/2.1 ms/21 ms/ Multiple output: Multiple output: 500 μs/2.1 ms/21 ms/ Multiple output:
2 ms/3 ms/11 ms/ 200 ms/1s selectable 3 ms/4 ms/14 ms/ 2 ms/ 3 ms/ 11 ms/ 200 ms/1s selectable 3 ms / 4 ms/ 14 ms /
100 ms/500 ms 1-Spot Mode Multiple outputs: 120 ms/600 ms 100 ms/ 500 ms 1-Spot Mode Multiple outputs: 120 ms/ 600 ms
selectable 2 ms/3 ms/11 ms/100 ms/ selectable selectable 2 ms/3 ms/11 ms/100 ms/ selectable
500ms selectable 500 ms selectable
2-Spot Mode Multiple outputs: 2-Spot Mode Multiple outputs:
2 ms/4 ms/21 ms/200 ms 2 ms/4 ms/21 ms/200 ms
/1 s selectable /1 s selectable
Mutual interference reduction function Up to 2 units with alternate frequencies set
Timer OFF /OFF delay /ON delay / One-shot
Power voltage 24 VDC, ripple (P-P) 10% or less, Class 2 or LPS
Power supply 135 mA or less (without load) 130 mA or less (without load) 120 mA or less (without load) 120 mA or less (without load) 115 mA or less (without load) 105 mA or less (without load)
Current consumption 335 mA or less 330 mA or less 320 mA or less 200 mA or less 195 mA or less 185 mA or less
(when 4 outputs are used, with load) (when 4 outputs are used, with load) (when 4 outputs are used, with load) (when 4 outputs are used, with load) (when 4 outputs are used, with load) (when 4 outputs are used, with load)
4 outputs max.
NPN open collector/ PNP open collector selectable
Control output 24 VDC or less, main unit: 50 mA or less*1, expansion unit: 20 mA or less
Remaining voltage: 2 V or less
N.O. / N.C. selectable
5 inputs max.
External input Short circuit current: 1 mA or less for NPN/ 2 mA or less for PNP
I/O
For the applied voltage, see the wiring diagrams in the instruction manual.
1 output max.
Current output/Voltage output selectable
Current output: 4 to 20 mA
Analogue output —
Maximum load resistance: 450 Ω
Voltage output: 0 to 10 V
External load resistance: 5 kΩ or more
Protection circuit Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection
Unit expansion Up to 4 units per main unit*2
Ambient temperature -20 to +50°C (no freezing)
Environmental Ambient humidity 35 to 85%RH (no condensation)
resistance Shock resistance 1000 m/ s2 in X, Y, Z axis directions respectively 6 times
Vibration resistance 10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z axis directions respectively, 2 hours
Material Case and dust cover: Polycarbonate, Button: Polyacetal, Display panel: Acrylic
Weight Approx. 70 g
*1 20 mA or less when an expansion unit is connected.
*2 Up to 5 N-bus devices, including the main unit (or network unit), can be linked together.
White (➁)/Orange/
Load
Grey/ Pink/Violet
White (➁) 2
(When analog
Main circuit
Main circuit
current /
Black(➃)/White(➁)/ voltage output 4
Orange/Grey circuit
(When control output is selected) PLC, Analogue input device
etc.
Blue*(➂) Blue(➂)
Blue*(➂) 0V 0V
0V
When PNP is selected When PNP is selected Power Cable wire colours
Brown*(➀) Brown*(➀) MU-N11 (main unit) MU-N12 (expansion unit)
24 VDC
24 VDC Wire colour Details Power cable model/type Wire colour Details Power cable model/type
Black(➃)/ White(➁)/ Brown (1*) 24 V Black Output 1 MU-CB2
Overcurrent protection circuit
24
Dimensions Unit: mm
Dial
Dial Button
Button
11.4 11
LR-W500 11.4 11 LR-W500C
Indicator
Indicator
13
13
18.5
18.5
STB C I
45.2
25.4
STB C I
46.7 45.2 32.2
Display 28.7 Display
28.7 32.2 14.9 13.3
Centre of
14.9 Centre of 13.3 received light
received light 12.5
45°
°
135 ø4.0, 4-core × Brown/ Reference surface
Reference surface Blue/Black/White 0.20 mm2 45° for detecting distance 2 × ø3.2
for detecting distance 2 × ø3.2 Cable length: 2 m
Pin layout
M12 connector
2
15.6
3 1
28.4 4
°
33.8
90
52
4.5
4.5 ø6.3 26.5 52.6
9 12.5
7 Centre of emitted light
4.5
.25) 6 9 11 11 9
0.6
- R2 Reference surface for detecting distance (50°)
(6
° 29
14°14° Centre of emitted light Non-adjustable area 29 °
2-R
3.5
3.5
2-R 9
9. Centre of received light
2
20 ø3 Non-
°
36
36°
adjustable
Rotational centre of area
main body Non-
adjustable
)
(4-R1.75 67
(33.4) 25.4 62.8 Non-adjustable area area
42 44.7
36°
30.9
36°
42
16
°
29
29
2-
°
R4
(50°)
25 2-M3 × 0.5 45.9
6.1
SUS304 SUS304
Plate thickness: 3 Plate thickness: 3
Centre of
received light
12.5 29.1
12.5 29.1
3.3
19.5 42.7 3.3 19.5 42.7 3.3
12.5 4.4 Zinc nickel plating
25
Dimensions
OP-88024 LR-WA1 + LR-W500 When OP-88023 + OP-88024 + LR-W500C Warning for when an
+ L-shape type M12 connector are used M12 connector type is used
R2
3.
ø12
5
Centre of emitted light
Centre of received light
105
64.7
Across flats: 18, (48.1) 45 31.8
thickness: 10 16.8
28.7 64.7
14.9
.5
3
15.2
R2
Iron nickel plating
1.3 13
)
(R73.9
11 3.3 (38.1) 33.7 33.7
LR-W70 LR-W70C
Button
Button
9.2 9.2
Indicator
Indicator
13
13
STB C I
44.5 42.65 44.5 42.65
32.2 Display 32.2
27.1 27.1 Display
15.5 13.3 15.5 13.3
Centre of received light Centre of received light
°
35 ø4.0, 4-core × Brown/
45°
12.5
1
Reference surface Blue/Black/White 0.20 mm2
for detecting distance 2 × ø3.2 Cable length: 2 m 45° Reference surface
for detecting distance 2 × ø3.2
8.7
8.7
M12 connector
10.9
°
90
28 22.6
52
4.5
4.5 ø6.3 21.1 24.2
47.9
6.2
9 12.5 Centre of emitted light 1
7
4.5 Centre of received light
.25) 6 9 11 11 9 5.3
Centre of emitted light 2
- R2 (50°)
(6
Reference surface for detecting distance 29
14° 14° ° °
29
3.5
3.5
2-R
2-R .9
39
2
20 ø
36°
Non-
Non-adjustable area adjustable
36°
area
Rotational centre
of main body Non-
) adjustable
(4-R1.75 67
(33.4) 25.4 60.5 Non-adjustable area area
42 43.1
36°
36°
42
31.5
16 29
° °
29
2-
R4
(50°)
25 2-M3 × 0.5 40.1
SUS304 SUS304 11.9
Plate thickness: 3 Plate thickness: 3
26
Unit: mm
11
5 16.6
19.7 39.4
6.2
3.5 3.5 Centre of emitted light 1
2-R
2 Centre of received light 1.3
47 7 17 (4)
Centre of emitted light 2
Non-adjustable Non-adjustable
18°
18°
12.5 area area
28.8
4.8 56.5 (33.4) 25.4 53 Non-adjustable Non-adjustable
18°
18°
Centre of area
3.4 35.6 area
received light
20.2 24
9.8 8.5 (6 )
2°
2-
) 2°
R4
(6
39 16.5 2-M3 × 0.5 2.7 36.3 10° 10°
SUS304 SUS304
t = 2.0 t = 3.0
36.9
17.9 Reference surface for
19.5 25.4 detecting distance
Reference surface for
23.7 detecting distance Centre of emitted light 1
23.7 6.2
ø27 17.4 3.2 ø22
Centre of emitted light 2
23.7 6.2
Centre of
Nut (M5, Iron nickel plating) 18.2 4.8 emitted light 1 18.5 1.1
Centre of 10.5
SUS304 emitted light 2 26
Centre of
received light
OP-88024 LR-WA2 + LR-W70 When OP-88023 + OP-88024 + LR-WF70C Warning for when an
+ L-shape type M12 connector are used M12 connector type is used
When mounting the unit as shown
Button
in the figure below (connector
2 × ø24, thickness: 2.5 Rotational centre of
main body downward), carefully check the
(40) 20.2 (19.9) surroundings for any objects that
M12 × P1.75 Indicator might interfere with the connector
Reference surface cable.
for detecting distance
ø12
R2
3.5
31.8
R2
8.7 29
27
Dimensions
LR-WF10 LR-WF10C
Button Button
9.2 9.2
Indicator 13 Indicator 13
STB C I
STB C I
42.65
T
44.5 42.65
R
32.2 Display
R
32.2
23.9 23.9 19.9 Display
19.9 13.3 13.3
35° 12.5
45°
1
2 × ø3.2
ø4.0, 4-core × Brown/ 45°
Blue/Black/White 0.20 mm2
Cable length: 2 m 2 × ø3.2
M12 connector
10.9
°
28 22.6
90
9 12.5
7
4.5
5 ) 5.3
6 9 11 11 9
2.2
-R
(6
14°14°
3.5
3.5
2-R
2-R 9
9.
2
20 ø3
)
(4-R1.75 67 R
SUS304 SUS304
Plate thickness: 3 Plate thickness: 3
OP-88022 + LR-WF10
7.75 3.5
OP-88022
11
5
19.8 39.4
3.5 3.5
2-R
2
4 7 7 17 (4) 1.3
25.4 8
2-R
9.5 3.5
12.5
28.8
4.8 56.5 (33.4) 25.4
T
3.4 R
53
32.4 28.4
20.2
9.8 8.5
2-
R4
28
Unit: mm
5.2 A 3
ø5.5 9*
lens 10 9.6 ø1.3 × 2 (Adaptor A)
A-A *
2.6
cross L 2000 18 500
section view
L: lens unit length
* Adjustable part 4.2 to 9.3 * Set-screw tightening area
ø3
1 8 × ø0.265
15 15 2000 1000
core fibre 12 5
FU-35TZ Free-cut
M3, P=0.5 Effective screw length: 12 FU-40 Free-cut
ø3.7 × 2 ø2.2 × 2
Nickel-plated brass ø1.3 × 2 lens
ø0.5 core fibre (Adaptor A)
8.1 9.5 4.4
1000
8 × ø0.265 21 2000
core fibre 5.2
12.5 SUS304
FU-40S Free-cut
FU-49U Free-cut
7.4 2-ø5.7 19 2000
8.2 7 2-ø3.5, ø6 spot facing ø0.5 × 2 core fibre
ø2 ø1.0 × 2
SUS303
7.3 17
(20)* ø2.2 × 2
10 1000
* Do not bend this part.
10* * Do not bend this part.
FU-83C
M4, P=0.7 SUS303
Across-flats: 7, t=2 ø4.2
ø1.45 ø2.6 Hexagonal clasp
core fibre
ø3.4 SUS304
3 14 10
1000
500 480 20
(-40 to +300°C)* (-40 to +200°C)* (-40 to +70°C)*
F-2HA + FU-35FZ F-2HA + FU-35TZ F-4HA + FU-35FZ F-4HA + FU-35TZ F-5HA + FU-35FZ
27 9.5 6
15.6 9.5 6
5.4
15 L 5 L=2.6 to 7.5
15.6 9 5 27 9 5
29
Dimensions
8.7
2.1
5.5 2.4 5.0
5.2 ø5.5 A 3 5.4 300
_ lens 15.0 1000
A A 2.6 10 9.6 M3, P=0.5
*
cross
section L 2000 5.6 L: 2.6 to 5.0
view
12.0 Housing: Aluminium
L: Lens unit length *Adjustable part 4.2 to 9.3
ø3.7 lens (black anodic oxide coating)
CZ-40 CZ-41
Slot (Note) 5.8 2-ø3.3 ø2.2 × 2
5.8 ø3.3 ø2.2 × 2
mounting hole 6.3 mounting hole
6.3 13.2
13.2
25.5 28.5 27
8 5
3.5
11.5 17.5
3.6 4
9.5 3.5
6 t=1.5
SUS304
11.5
33
(4)
15 9 5 ø4.5
ø10.6 Chamfered (2) ø3.5
SUS303 SUS304
3.6
28 2 2000 (3.5)
7 5
12 300
26 1000
30
Unit: mm
28 28
28 28
19.5 23.7 35.4 19.5 23.7 35.4
78.4 21 78.4 21
When mounting adapter is attached (OP-76877, optional, sold separately) When the communication unit is connected without using a power supply cable
28
18.8 19
5 Maximum when
27.2
cover is open: MAX.
2 × ø3.4 108 135°
34 15
(41.9) 36.9
2×(4.4 × 3.4)
15.8
22 28
24
When expansion units are connected End unit (OP-26751, optional, sold separately)
(22.6) 20.8
9.2 35.4
53.8
6 L 6
31
Dimensions Unit: mm
43 OP-75721:2000/OP-87272:5000/OP-85502:10000
33.8 OP-75722:2000/OP-87273:5000/OP-87274:10000
ø14
M12
28.2
ø14
ø14.8 27.4
No. Colour
Pin layout 2 Brown
➀
1 3 ➁ White
4
➂ Blue
➃ Black
ø14
M12
28.2
ø14
ø4.0 (4 × 0.20 mm2) ø4.0 (4 × 0.20 mm2)
X X Y Colour Y X X Y Colour Y
M12 Connector pin layout Connector pin layout M12 Connector pin layout Connector pin layout
➀ ➀ Brown ➀ ➀ Brown
➁ ➁ White ➀ ➁ ➁ White ➀
2 ➁ 2
1 3 Blue ➂ ➂ Blue ➁
➂ ➂ ➂ 1 3
➂
4 4
➃ ➃ Black ➃ ➃ ➃ Black ➃
32
Network communication unit NU Series
EtherNet/IPTM NU-EP1
OP-51505 STP (Shielded twisted-pair) cable 0.5 m
PROFINET NU-PN1
OP-51509 STP (Shielded twisted-pair) cable 10 m
The NU Series models also have the following communication units: CC-Link-compatible NU-CL1 and DeviceNetTM-compatible NU-DN1.
33
EtherCAT compatible communication unit: NU-EC1
Model NU-EC1
Compliant standards IEEE802.3u (100BASE-TX)
Transmission rate 100 Mbps (100BASE-TX)
Ethernet specifications Transmission media Category5e or higher STP
Distance between nodes 100 m
Communication port RJ-45 × 2
EtherCAT communication Process data object communication (cyclic communication)
Supported functions
specifications Mailbox communication (message communication) CoE compatible
Connectable sensor N-bus sensor amplifier*1
Sensor connection Number of connectable sensors 16 units max.*2
specifications Power supply Supplied from the unit via a wiring-saving connector
Allowable passing current*3 1200 mA or less total
Power voltage 24 VDC ±10%, ripple (p-p) 10% or less
Power consumption 1700 mW or less (70 mA max. at 24 V)*4
Weight (including connector) Approx. 80 g
Accessories Instruction manual, power supply connector, end unit × 2
* EtherCAT is a registered trade name of BECKHOFF.
*1 N-bus is the name of KEYENCE's simplified wiring system for sensor amplifiers.
*2 Varies depending on the sensor amplifier to be connected.
*3 This is the current value that can be supplied to this unit or the sensor amplifier connected to this unit.
*4 Excluding the current supplied to the connected sensor amplifier.
34
Dimensions Unit: mm
NU-EP1/PN1 25.6
29.4 15
38.5
(42.5) 20.3
15
(0.2)
43.5 35.4
94.5 17.6
NU-EC1
15.8 22.2
29.4 15
170°
1.9 max. Maximum when
the cover is opened
73.6
34.1
20.3
(38.5) 15
(0.2)
43.5 35.4
94.5 17.6
C A D D ATA D O W N L O A D
www.keyence.com/CADG
35
LR-W
SERIES
Self-Contained
Full-Spectrum Sensor
SAFETY INFORMATION
Please visit: www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.
The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. WW1-2090
Company and product names mentioned in this catalogue are either trademarks or registered trademarks of their respective companies. Unauthorised reproduction of this catalogue is strictly prohibited.
Copyright © 2016 KEYENCE CORPORATION. All rights reserved. LRW_EU-WW-C2-GB 2071-4 600I20