Proper distances between PCB traces are critical to avoid flashover or tracking between electrical
conductors. Unfortunately, there is no single solution to this issue. There is a variety of industry
and safety standards that prescribe different spacing requirements depending on the voltage,
application and other factors. Here I am providing some considerations and a simple widget that
will help you determine the proper spaces between PCB tracks.
OPERATIONAL REQUIREMENTS
The distances provided by IEC and UL actually
1 of 5 10/14/2021, 10:51 AM
PCB Trace Spacing Calculation for Voltage Levels https://www.smps.us/pcbtracespacing.html
2 of 5 10/14/2021, 10:51 AM
PCB Trace Spacing Calculation for Voltage Levels https://www.smps.us/pcbtracespacing.html
One would think that a general PCB design standard has to be more liberal than UL requirements.
In reality, for V>150V IPC actually calls for larger spacings between uncoated external conductors
than those you can derive from UL 60950-1 Table 5B in conjunction with the 40V/mil criterion.
Note that generally all IPC doc's are voluntarily rather then mandatory. Particularly, they state that
"Existence of such Standards and Publications shall not in any respect preclude any member or
nonmember of IPC from manufacturing or selling products not conforming to such Standards and
Publication".
Where shortage of space on a PCB is an issue, for non-UL applications you may need to use the
spacing smaller than those that are prescribed by IPC. However, be sure to use an ample safety
factor to withstand the voltages substantially higher than the peak voltage between the copper
traces under any abnormal and transient conditions. It is interesting to note that many major
power supply manufacturers in their low-power off-line designs are widely using 500-800V
MOSFETs in TO220 package operating at 400V and higher. With this package you can get about
30 mils spacing between the pads, while the documents would require at least 100 mils. Even if
you spread the leads on the PWB, you can't do anything with 50-mil spacing between the TO220
leads along the surface of the package.
As a reference, the chart below compares PCB distance limits based on the following three specs
for external layers of uncoated bare boards;
IPC2221B
IPC9592B;
UL60950 for functional insulation in secondaries, designed to meet the test per Table 5B with
the assumption of 40V/mil withstand voltage.
Note the curves below are for functional (not safety!) insulation.
3 of 5 10/14/2021, 10:51 AM
PCB Trace Spacing Calculation for Voltage Levels https://www.smps.us/pcbtracespacing.html
CONCLUSION
When the product is covered by an UL standard, you need to select the appropriate table in the
UL standard. Particularly, for the products covered by UL60950-1, determine the grade of
insulation depending on the location of the circuits and then find from Tables 2K-2N minimum
required spacing based on working voltage, pollution degree, PCB material group and the coating.
For functional insulation UL permits usage of lesser distance if it withstands the test voltage per
Table 5B. For practical purposes, in my view, you can calculate the distance on the assumption
that the circuit board withstands 40V/mil (1.6kV/mm). Of course, this test voltage is always much
higher than actual operating voltage. Also note that technically the insulation requirements given
in UL 60950 are for frequencies up to 30 kHz. So far, both 60950-1 2nd Edition and IEC 62368-1
permit the same requirements for frequencies above 30 kHz until they will figure out what to do
about it. You can't rule out that in the future IEC and UL would adopt tougher standards for high
frequency circuits based on IEC 60664-1 and IEC 60664-4, which would have a major effect on
most SMPS designs.
If there is no legal requirement to meet UL or any other product control law, try using IPC-2221B
(or IPC-9592B for power circuits) distance recommendations whenever possible. However, where
shortage of space on a PCB is an issue, you may need to choose a smaller spacing, provided it
still withstands test voltages substantially higher than the peak voltage between the traces. The
above analysis takes into account only electrical breakdown issue. There are other criteria that
should be considered when selecting electrical clearance, such as conductor's temperature rise.
Also see general guidelines for printed circuit board design, layout rules for power circuits, and
signal integrity issues.
4 of 5 10/14/2021, 10:51 AM
PCB Trace Spacing Calculation for Voltage Levels https://www.smps.us/pcbtracespacing.html
LEGAL. The information provided here reflects only a personal opinion of the author and does not constitute a
professional or legal advice. It is not intended to substitute official standards-- consult them for all final decisions.
Also see our general Disclaimer linked below.
5 of 5 10/14/2021, 10:51 AM