You are on page 1of 1

PO BOX 368, MOUNT GRAVATT, QLD, 4122, AUSTRALIA

QBCC LICENCE NO. 1260984

COPYRIGHT EAST COAST CONSTRUCTION COMPANY PTY. LTD.


REPRODUCTION OF THE WHOLE OR PART OF THE DOCUMENT
CONSTITUTES AND INFRINGES COPYRIGHT. THE INFORMATION,
IDEAS AND CONCEPTS CONTAINED IN THIS DOCUMENT ARE
14360
CONFIDENTIAL. THE RECIPIENT(S) OF THIS DOCUMENT ARE
PROHIBITED FROM DISCLOSING SUCH INFORMATION IDEAS
13115 AND CONCEPTS TO ANY PERSON WITHOUT PRIOR WRITTEN
CONSENT OF THE COPYRIGHT HOLDER. ECCC HOLDS A
LICENSE FROM ARBT IN RESPECT OF PROPRITARY ITEMS
12020
NOTE THIS DRAWING IS PREPARED BY EAST COAST

3186
CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE FOR
20060 THE USE OF EAST COAST CONSTRUCTION COMPANY PTY LTD
20853 14224 AS THE CONTRACTOR ON THIS PROJECT

20060 SUB- CONTRACTORS TO CHECK AND VERIFY ALL LEVELS,


DATUMS & DIMENSIONS ON SITE AND SHALL REPORT ANY
DISCREPANCIES OR OMISSIONS TO THIS OFFICE PRIOR TO
START OF WORK & DURING THE CONSTRUCTION PHASE.
THE DRAWING ARE TO BE READ IN CONJUNCTION WITH
SPA
STRUCTURAL, MECHANICAL, ELECTRICAL AND OR ANY OTHER

1715
CONSULTANTS DOCUMENTATION AS MAY BE APPLICABLE TO
2650 THE PROJECT PRIOR TO STARTING & DURATION OF THE WORKS.
1:10
20060 1800

8364
1871

5600

5400
UNISEX
PWD 15800
20853

3060
18460
14204

CH - 4460 2650
20060 CH - 2860
CH - 4460

2650 20060

10693
UNISEX

1550
2435 1275 7243 1000

656
16479

1276
CH - 4460
1050 1050
20060 MANAGER'S OFFICE

50
CH - 2860

2365

2365

1190
2650

2313
20060 LIFT 1 CH - 4460 CH - 4460
11970
20060
4317

1:14
4588

3824
1626 CH - 4460
LIFT 2
1:14

3665

0
9698 3100 8035 18460
8036

3236
18460
2612

MANAGER'S UNIT
20060 CH - 2860 1733
20060 ENSUITE CH - 2860

1:20
1805

1921
CH - 2860 1906 20060
1:14 CH - 2860

6893
6502
6685

3365

1230
1713
2007

1744
3964 2359
CH - 4460
18460 3305
19700 BED 2
MSB
8488 2002

3388
FCR CH - 2860 BED 1 CH - 2860

2655

3345
2911
1:14 CH - 2500 BATH
CH - 2860

1614
KITCHEN
2773

3139 245
1900
3910
2915 1631
CH - 2860

351
RC ROOF OVER STAIR
TO FIRE PUMB ROOM

B 22.04.20 BB KF UPDATED AS PER INSTRUCTION


A 09.03.20 BB KF PRELIMINARY ISSUE
REV DATE DRN CKD DESCRIPTION

1:14 1:14 1:18

Owner

Carl Street
GROUND FLOOR RCP
General Notes:
1. All penetrations for services through metal stud joists and supports shall be fitted with snap bushes to protect services from sharp LEGENDS: Notes:
edges.
- ALL THE CEILING HEIGHTS ARE MEASURED FROM STRAKEN PANEL
2. All services shall be securely clamped to avoid displacement and damage through transport, movement , water hammer etc and
as detailed in the services layout RCP drawing.
- 16mm FIRE CEILING BOARD
-
-
ALL DROPS ARE MEASURED FROM FIRE CEILING LEVEL
ALL TOILET CELINGS CEILINGS ARE FIXED AT SITE ONLY
PROJECT NUMBER 1802
- DIMENSIONS ARE ALL MEASURED FROM FINISH TO FINISH
3. False ceilings linings, framing etc shall be fabricated with non combustable materials. - ACCESS PANEL LOCATION IN TOILET TO BE VERIFED BY FACTORY
- 9.5mm UNISPAN BORAL BOARD
DATE 09.04.2020
4. Fixings for services and fixings for wall studs below fire ceiling layer shall not be located at fire sheet joints.

5. All fire ceiling joints shall be taped and set prior to installation of false ceilings and full height walls and sheets laid in a staggered
pattern. - 6mm FC HUME BOARD

6. penetrations through fire ceiling layer for vertical plumbing pipes shall be made with clean square edges with casing bead left

30-04-2020 7.02.39 PM
ready for site fixed linings and fire collars as detailed .

7. Fire linings shall be completed to full perimeter edge of modules.

8. Check and confirm items 1 to 7 above prior to sheeting false ceilings


A 203
9. For Lighting layout refer electrical drawing.

SCALE: As
indicated
NORTH